Vickers
®
PVM Piston Pumps
18-141cc
3
(1.1-8.6in
3
)
M-Series
Industrial Variable
Displacement
M-Series
Mobile Variable
Displacement
2 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Table of
Contents
Principles of Operation ...................................................................................... 3
Hydraulic System Design Calculations ......................................................................... 4
Introduction ............................................................................................... 5
Model Code Selection ....................................................................................... 6
Model Code Options ........................................................................................ 7
Specifications and Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Control Options ........................................................................................... 12
Performance Industrial & Mobile
PVM018 ........................................................................................... 16
PVM020 ........................................................................................... 21
PVM045 ........................................................................................... 26
PVM050 ........................................................................................... 31
PVM057 ........................................................................................... 36
PVM063 ........................................................................................... 41
PVM074 ........................................................................................... 46
PVM081 ........................................................................................... 51
PVM098 ........................................................................................... 56
PVM106 ........................................................................................... 61
PVM131 ........................................................................................... 66
PVM141 ........................................................................................... 71
Dimensions
PVM018/020 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
PVM045/050 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
PVM057/063 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
PVM074/081 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
PVM098/106 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
PVM131/141 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
Mounting Flange Options .................................................................................. 108
Shaft Options ............................................................................................ 109
Input Shaft Selection Data ................................................................................. 112
Port Options ............................................................................................. 113
Operating Requirements and Recommendations .............................................................. 115
Installation and Start-up ................................................................................... 116
M Series Variable Displacement Piston Pumps
3EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Principles of
Operation
In axial piston pumps, the
pistons reciprocate parallel
to the axis of rotation of the
cylinder block. The simplest
type of axial piston pump
is the swash plate in-line
design.
The cylinder block in this
pump is turned by the drive
shaft. Pistons fitted to bores
in the cylinder block are con-
nected through piston shoes
and a shoe plate, so that the
shoes bear against an angled
swash plate.
As the block turns, the pis-
ton shoes follow the swash
plate, causing the pistons to
reciprocate. The ports are
arranged in the valve plate
so that the pistons pass the
inlet as they are pulled out
and pass the outlet as they
are forced back in.
The displacement of axial
piston pumps is determined
by the size and number of
pistons, as well as the stroke
length which is determined
by the angle of the swash
plate.
In variable displacement
models of the in-line pump,
the swash plate is installed
in a movable yoke.
“Pivoting” the yoke on pin-
tles changes the swash plate
angle to increase or decrease
the piston stroke.
Piston Pump Operation
4 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Hydraulic
System Design
Calculations
Basic Formulas
Output Flow (Q)
lpm = gpm =
Input Power (P)
kW = hp =
Shaft Torque (M)
N-m = lb-in =
Shaft Speed (n)
rpm = RPM =
Output Power (P)
kW = hp =
Volumetric Displacement
cm
3
/r = in
3
/r =
Basic Formulas
bar = 10 Newtons/cm
2
gpm = gallons per minute
hp = horsepower
lb-in = pound inch
lb-ft = pound feet
kW = kilowatt
kgf = kilograms force
l/min = liters per minute
N-m = Newton meters
psi = pounds per square inch
rpm = revolutions per minute
Efficiencies
Volumetric Nv =
Mechanical Nm =
Total Nt = Nv x Nm
Commonly Used Conversions
To Convert Into Multiply by
bar psi 14.5
cm
3
in
3
0.06102
˚C ˚F (˚C x 1.8) +32
gallons (US) liters 3.785
kg lbs 2.205
kgf/cm
2
psi 14.2
kW hp 1.341
liters US Gallons 0.2642
mm inches 0.03937
N-m lb-in 8.85
N-m lb-ft 0.7375
˚F ˚C (˚F-32)/1.8
hp kW 0.7457
inch mm 2.54
in
3
cm
3
16.39
lb-in N-m 0.113
lb-ft N-m 1.356
lbs kg 0.4535
psi bar 0.06896
psi kgf/cm
2
.070307
Note: Performance charts can be found on subsequent pages.
cm
3
/r x rpm in
3
/r x rpm
1000 231
l/min x bar gpm x psi
600 1714
bar x cm
3
/r psi x in
3
/r
62.8 6.28
1000 x 1/min 231 x gpm
cm
3
/r in
3
/r
N-m x RPM lb-in x rpm
9549 63,025
lpm x 1000 gpm x 231
rpm rpm
P
M
n
Q
p
gpm actual
gpm theorectical
lb-in actual
lb-in theorectical
5EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Introduction
Eaton Vickers
®
M Series mobile pumps are open
circuit, axial piston designs. A variety of controls
provides the ability to match the pumps to each appli-
cation. Efficiency of the pump controls allows down-
sizing of system cooling needs, allowing a smaller
and less expensive design to be used. Alternatively,
cooling capacity could be kept the same and the flow
capability of the system increased, thus improving
performance and customer satisfaction.
A strong proven rotating group allows the pumps to
handle pressures to 280 bar (4000 psi) continuous and
320 bar (4600 psi) intermittent – with less maintenance
cost. High-load bearings and a stiff drive shaft help
provide a pump life of 5000 hours at rated mobile
conditions, reducing operating costs and extending
operating life.
M Series pumps feature a saddle-type yoke with
steel-backed polymer bearings. The stiff yoke reduc-
es deflection and allows even loading of bearings,
improving life. A single control piston reduces load-
ing on the yoke, resulting in reduced pump size which
allows installation in tighter locations.
M Series pumps operate at a level of quietness that
exceeds the requirements of today’s demanding work
conditions. The pumps feature a unique three-piece
envelope (flange, housing and valve block) specifically
created for low fluid-borne and structure-borne noise
levels. Another pump feature a bimetal timing plate
improves pump filling characteristics which, in turn,
reduce fluid-borne noise and extend pump life.
Proximity of the pump to the vehicle operator
demands a low noise level in the cab. M Series pumps
reduce, or in some cases remove, the need for damp-
ing barriers between the noise source and the opera-
tor. This saves money on the installed cost of the
system while improving customer comfort.
An adjustable maximum stop provides a means of
tuning flow to your system, while gauge ports allow
monitoring of inlet and outlet conditions. These stan-
dard features reduce system complexity and cost.
Mounting flanges are offered in SAE and ISO con fig-
urations, and ports are offered in SAE, ISO, and BSPP
in both tube and flange versions. This provides a
wide variety of installation opportunities for global
machine design.
Side- or end-ported models are available to facilitate
plumbing and help fit the pump to your machine
space needs. Multiple drain ports allow many mount-
ing orientations, reducing installed costs.
M Series pumps are capable of operating with many
types of hydraulic fluids used in industrial and mobile
systems. High-water-content and phosphate ester
fluids can be accommodated, in addition to the typical
petroleum based and synthetic fluids.
Typical Applications
Loader backhoes
Vibratory cable plows
Mining machinery
Dump truck lifts
Agriculture tractors
Chemical applicator trucks
Railroad equipment
Container handling, all-terrain,
and truck cranes
Vibratory cable plows
Mining machinery and tunnel
boring equipment
Utility boom, off-road dump,
and refuse trucks
Material handling trucks and
rough terrain fork lifts
Concrete and asphalt pavers
Feller/bunchers, forwarders,
and log loaders
Crawler dozers
Articulate haulers
Mini-excavators
Features and Benefits
Long pump life
Quiet pump operation
Inlet and outlet gauge ports
and adjustable maximum
displacement stops
standards
Astonishingly low 4%
pressure ripple
Low installed and
operating costs
Reduced maintenance
Flexibility in machine design
Compact size saves space
Design promotes leak-free
system
6 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Model Code
Selection
1, 2, 3
Product Series
PVM M Series Variable
Piston Pump
4, 5, 6
Displacement
Fourteen displacements
available 230 bar and 280 bar
continuous ratings
7
Valve Plate
M Mobile Equipment
Speeds (Higher Speed)
8
Input Rotation
R – Clockwise (Righthand)
L* Counter-clockwise
(Lefthand)
9, 10
Input Shaft
Standard SAE and ISO splined
versions (Other configurations
optional)
11
Mounting Flange
Thirteen options in SAE and
ISO mounts
12
Main Port Location
E** – End Ported
S Side Ported
13, 14
Main Port Type
SAE & ISO tube ports and
4-bolt ange (Other
configurations optional)
15, 16
Pump Special Features
00 None
AA Adjustable Maximum
Displacement Stop and
single shaft
(standard)
AB Double Shaft Seal, Two
Way
17
Control
0 – None
A – Pressure Compensator
B Pressure and Flow
Compensator with Bleed
Orifice
C Pressure and Flow
Compensator with
Plugged Orifice
E Industrial Control (57cc
through 141 cc only)
18, 19
Pressure Compensator
Setting
00 – None
07 70 bar (Adjustable
between 40 bar and
130 bar)
23 230 bar (Adjustable
between 130 bar and
320 bar)
28 280 bar (Adjustable
between 130 bar and
320 bar)
20, 21
Flow Compensator
Setting
00 – None
11 – 11 bar setting
20 – 20-20 bar setting
24 – 24-24 bar setting
22, 23
Torque Limiter Setting
00 None (Not available on
M Series)
24
Compensator Special
Features
0 None
25
Auxiliary Mounting Pad
0*** – None
(Auxiliary mounting available
on all frame sizes)
26
Paint
0 – No Paint
A – Standard Blue Paint
27
Customer Identification
0 None (Contact Eaton
for Options)
28
Design Code
A – A (Initial Release)
PVM 018 M R 01 A E 01 AA A 28 00 00 0 0 A 0 A
1, 2, 3 9, 10 13, 14 15, 16 18, 19 20, 21 22, 23
4, 5, 6
7 8 11 12 17 24 25 26 27 28
* Not available on 074, 081, 098 and 106 End Port
** Not available on 074, 081, 098 and 106 LH
*** Through drive not available on the LH
7EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Model Code
Options
4,5,6 Maximum geometric displacement
Displacement Code 018 020 045 050 057 063 074 081 098 106 131 141
cm
3
/r 18,0 21,1 45,1 50,0 57,4 63,1 73,7 81,0 98,3 106,5 131,1 141,0
in
3
/r 1.1 1.29 2.75 3.05 3.50 3.85 4.50 4.94 6.00 6.50 8.00 8.60
11 Mounting flange specifications
Code Description PVM018/020 PVM045/050 PVM057/063 PVM074/081 PVM098/106 PVM131/141
A SAE A, 2-bolt l
B ISO 80A2HW l
C SAE B, 2-bolt l l l
D ISO 100A2HW l l l
E SAE C, 2-bolt l l l l
F ISO 125-A2HW l l l l
G SAE C, 4-bolt l l l l
H ISO 125B4HW l l l l
J SAE D, 4-bolt l
K ISO 160B4HW l
l = Available
= Not Available
9,10 Shaft-end type at electric motor end
Shaft Code
Description PVM018/020 PVM045/050 PVM057/063 PVM074/081 PVM098/106 PVM131/141
SAE, SAE A, Straight Keyed 01
SAE, SAE 19-1, Straight Keyed 02
SAE, SAE A, 9T Spline 03
SAE, SAE A, 11T Spline 04
SAE, SAE B, Straight Keyed 05 05
SAE, SAE B-B, Straight Keyed 06 06 06
SAE, SAE B, 13T Spline 07 07 07
SAE, SAE B-B, 15T Spline 08 08 08
SAE, SAE C, Straight Keyed 09 09 09 09
SAE, SAE C-C, Straight Keyed 10 10 10
SAE, SAE C, 14T Spline 11 11 11 11
SAE, SAE C-C, 17T Spline 12 12 12
SAE, SAE D, Straight Keyed 13
SAE, SAE D, 13T Spline 14
ISO E20N,
Straight Keyed 15
ISO E25N,
Straight Keyed, Short Spigot 16
ISO E25N,
Straight Keyed 17 17 17
ISO E32N,
Straight Keyed, Short Spigot 18 18 18 18
ISO E40N,
Straight Keyed, Short Spigot 19 19 19
8 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Model Code
Options
13,14 Main Port Options
Inlet
Code Description Outlet PVM018/020 PVM045/050 PVM057/063 PVM074/081 PVM098/106 PVM131/141
Inlet –20 –24 –24
01
SAE J1926
(End ports only)
Tube Ports
Outlet –12 –16 –16
(End ports only)
02
SAE J518
Inlet 1.25 inch 2.0 inch 2.0 inch 2.0 inch 2.5 inch 2.5 inch
Flange Ports
Outlet 0.75 inch 1.0 inch 1.0 inch 1.0 inch 1.0 inch 1.25 inch*
Inlet M42 M48 M48
03
ISO 6149-1
(End ports only)
Tube Ports
Outlet M27 M33 M33
(End ports only)
04
ISO 6162
Inlet 32mm 51mm 51mm 51mm 64mm 64mm
Flange Ports
Outlet 19mm 25mm 25mm 25mm 25mm 32mm*
British Standard
05 Parallel Pipe
Inlet G 1-1/4 G 1-1/2
Tube Ports
Outlet G 3/4 G 1
*SAE Code 62, high pressure series, or ISO 400 bar. Other flange ports are SAE Code 61, standard pressure series, or ISO 25-350 bar.
25 Thru-Drive Options
Code Description PVM018/020 PVM045/050 PVM057/063 PVM074/081* PVM098/106 PVM131/141
O Single pump,
non-thru-drive l l l l l l
A SAE A, 2-bolt,
9T spline l l l l l l
B SAE A, 2-bolt,
11T spline l l l l l
C SAE B, 2-/4-bolt,
13T spline l l l l l
D SAE B-B, 2-/4-bolt,
15T spline l l l l l
E SAE C, 2-/4-bolt,
14T spline l l l l
F SAE C-C, 2-/4-bolt,
17T spline l l l
G ISO 80-A2HW,
9T SAE spline l l l l l l
H ISO 80-A2HW,
11T SAE spline l l l l l
J ISO 100-A2/B4HW,
13T SAE spline l l l l l
K ISO 100-A2/B4HW,
15T SAE spline l l l l
L ISO 125-A2/B4HW,
14T SAE spline l l l l
M ISO 125-A2/B4HW,
17T SAE spline l l l
l = Available
= Not Available
* Not available on the 074/081 LH
9EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Specifications
and
Performance
Industrial
Displacement, Pressure and Flow Ratings At 50°C (120°F), SAE 10W oil, 1 bar absolute (0 psig) inlet
Maximum
Maximum Flow at 210 bar (3000 psi)
Geometric
Maximum Pressure bar (psi) l/min (USgpm)
Displacement @1800 @1500 @1200 @1000
Model Series cm
3
/r (in
3
/r) Continuous Intermittent* Peak** r/min r/min r/min r/min
PVM018 18 (1.1) 280 (4000) 320 (4600) 350 (5000) 31 (8.2) 26 (7) 21 (5.5) 17 (4.5)
PVM020 21,1 (1.29) 230 (3300) 250 (3600) 280 (4000) 35 (9) 29 (8) 23 (6) 19 (5)
PVM045 45,1 (2.75) 280 (4000) 320 (4600) 350 (5000) 76 (20) 65 (17) 49 (13) 42 (11)
PVM050 50,0 (3.05) 230 (3300) 250 (3600) 280 (4000) 87 (23) 75 (20) 62 (16) 49 (13)
PVM057 57,4 (3.50) 280 (4000) 320 (4600) 350 (5000) 102 (27) 85 (22.4) 66 (17.4) 54 (14.3)
PVM063 63,1 (3.85) 230 (3300) 250 (3600) 280 (4000) 111 (29) 93 (24) 74 (19) 60 (16)
PVM074 73,7 (4.50) 280 (4000) 320 (4600) 350 (5000) 127 (33.5) 106 (28) 86 (22.7) 70 (18.5)
PVM081 81,0 (4.94) 230 (3300) 250 (3600) 280 (4000) 139 (37) 116 (31) 93 (25) 76 (20)
PVM098 98,3 (6.00) 280 (4000) 320 (4600) 350 (5000) 170 (45) 141 (37) 112 (29.6) 92 (24.3)
PVM106 106,5 (6.50) 230 (3300) 250 (3600) 280 (4000) 187 (49) 155 (41) 123 (32) 102 (27)
PVM131 131,1 (8.00) 280 (4000) 320 (4600) 350 (5000) 215 (57) 178 (47) 141 (37) 118 (31)
PVM141 141,0 (8.60) 230 (3300) 250 (3600) 280 (4000) 238 (63) 199 (53) 158 (42) 131 (35)
**Less than 10% of duty cycle.
**Momentary system pressure spikes only.
Speed, Input Power and Torque Ratings At 50°C (120°F), SAE 10W oil, 1 bar absolute (0 psig) inlet
Maximum
Maximum Torque at
Operating 210 bar Approximate
Model Speed
Maximum Input Power at 210 bar (3000 psi) kw (hp)
(3000 psi) Weight
Series r/min @1800 r/min @1500 r/min @1200 r/min @ 1000 r/min Nm (lb-ft) kg (lb)
PVM018 1800 16 (22) 13 (18) 11 (15) 9 (12) 84 (62) 15 (33)
PVM020 1800 14 (18) 11 (15) 9 (12) 8 (10) 73 (54) 15 (33)
PVM045 1800 41 (55) 34 (46) 27 (37) 23 (31) 221 (163) 24 (52)
PVM050 1800 35 (47) 30 (40) 28 (38) 23 (31) 190 (140) 24 (52)
PVM057 1800 52 (70) 44 (59) 36 (49) 29 (39) 272 (201) 36 (79)
PVM063 1800 42 (57) 36 (48) 29 (39) 24 (32) 228 (168) 36 (79)
PVM074 1800 63 (84) 52 (70) 42 (56) 35 (47) 334 (246) 45 (99)
PVM081 1800 56 (75) 46 (62) 35 (47) 28 (37) 286 (211) 45 (99)
PVM098 1800 88 (118) 72 (97) 58 (78) 48 (64) 464 (342) 55 (121)
PVM106 1800 72 (97) 60 (80) 48 (64) 40 (54) 383 (282) 55 (121)
PVM131 1800 113 (152) 94 (126) 75 (101) 63 (85) 596 (440) 66 (145)
PVM141 1800 94 (126) 79 (106) 63 (85) 53 (71) 497 (367) 66 (145)
Standard Response Times*
Model Series On Stroke (msec) Off Stroke (msec)
PVM018 30 25
PVM020 39 26
PVM045 140 40
PVM050 140 40
PVM057 65 20
PVM063 85 20
Standard Response Times*
Model Series On Stroke (msec) Off Stroke (msec)
PVM074 85 30
PVM081 85 30
PVM098 65 25
PVM106 72 29
PVM131 135 30
PVM141 100 30
*Values with pressure compensator control.
10 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Specifications
and
Performance
Mobile
Displacement, Pressure and Flow Ratings At 93°C (200°F), SAE 10W oil, 1 bar absolute (0 psig) inlet
Geometric
Maximum Pressure bar (psi) Maximum Flow at 280 bar (4000 psi)
Displacement Flange Ports Tube Ports
Model Series cm
3
/r (in
3
/r) Continuous Intermittent* Peak** l/min (USgpm) @ 1 bar inlet l/min (USgpm) @ 1 bar inlet
PVM018 18,0 (1.10) 280 (4000) 320 (4600) 350 (5000) 46 (12) @ 2800 r/min 46 (12) @ 2800 r/min
PVM020 20,1 (1.22) 230 (3300) 250 (3600) 280 (4000) 53 (14) @ 2800 r/min 53 (14) @ 2800 r/min
PVM045 45,1 (2.75) 280 (4000) 320 (4600) 350 (5000) 115 (30) @ 2600 r/min 106 (28) @ 2400 r/min
PVM050 50,0 (3.05) 230 (3300) 250 (3600) 280 (4000) 125 (33) @ 2600 r/min 116 (31) @ 2400 r/min
PVM057 57,4 (3.50) 280 (4000) 320 (4600) 350 (5000) 140 (37) @ 2500 r/min 128 (34) @ 2300 r/min
PVM063 63,1 (3.85) 230 (3300) 250 (3600) 280 (4000) 150 (40) @ 2500 r/min 140 (37) @ 2400 r/min
PVM074 73,7 (4.50) 280 (4000) 320 (4600) 350 (5000) 163 (43) @ 2400 r/min
PVM081 81,0 (4.94) 230 (3300) 250 (3600) 280 (4000) 181 (48) @ 2400 r/min
PVM098 98,3 (6.00) 280 (4000) 320 (4600) 350 (5000) 200 (53) @ 2200 r/min
PVM106 106,5 (6.50) 230 (3300) 250 (3600) 280 (4000) 222 (59) @ 2200 r/min
PVM131 131,1 (8.00) 280 (4000) 320 (4600) 350 (5000) 233 (62) @ 2000 r/min
PVM141 141,0 (8.60) 230 (3300) 250 (3600) 280 (4000) 258 (68) @ 2000 r/min
**Less than 10% of duty cycle.
**Less than 0.5 second.
Standard Response Times*
Model Series On Stroke (msec) Off Stroke (msec)
PVM018 50 20
PVM020 57 22
PVM045 140 40
PVM050 140 23
PVM057 65 20
PVM063 94 20
Standard Response Times*
Model Series On Stroke (msec) Off Stroke (msec)
PVM074 95 30
PVM081 135 30
PVM098 85 24
PVM106 90 25
PVM131 100 30
PVM141 128 28
*Values with pressure compensator control.
11EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Specifications
and
Performance
Mobile
Speed, Input Power and Torque Ratings At 93°C (200°F), SAE 10W oil, 1 bar absolute (0 psig) inlet
Minimum Operating Speed and Pressure r/min
Max. Input Power at Max. Torque at Approximate
1 bar Inlet 0,85 bar Inlet
Max. Speed and 280 bar 280 bar (4000 psi) Weight (dry)
Model Series Flange Ports Tube Ports Flange Ports (4000 psi) kW (hp) Nm (lb-ft) kg (lbs)
2800 r/min 24 (32)
PVM018 2800 r/min 24 (32) 82 (60) 15 (33)
2600 r/min 22 (30)
2800 r/min 21 (28)
PVM020 2800 r/min 21 (28) 72 (53) 15 (33)
2600 r/min 20 (27)
2600 r/min 56 (75)
PVM045 2400 r/min 53 (71) 198 (46) 24 (52)
2200 r/min 48 (64)
2600 r/min 51 (68)
PVM050 2400 r/min 48 (64) 204 (150) 24 (52)
2200 r/min 44 (59)
2500 r/min 68 (91)
PVM057 2300 r/min 62 (83) 262 (193) 36 (79)
2100 r/min 56 (75)
2500 r/min 59 (79)
PVM063 2400 r/min 57 (76) 225 (166) 36 (79)
2200 r/min 52 (69)
PVM074
2400 r/min 84 (113)
334 (246) 45 (99)
1900 r/min 69 (93)
PVM081
2400 r/min 69 (93)
276 (204) 45 (99)
1900 r/min 55 (74)
PVM098
2200 r/min 105 (141)
457 (337) 55 (121)
1800 r/min 86 (115)
PVM106
2200 r/min 87 (117)
377 (278) 55 (121)
1800 r/min 70 (94)
PVM131
2000 r/min 122 (164)
581 (429) 66 (145)
1600 r/min 98 (131)
PVM141
2000 r/min 102 (137)
483 (356) 66 (145)
1600 r/min 81 (109)
12 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Control Options
Pressure Compensator
Control – Code A
The pump will provide a continu-
ously modulated ow to meet
changing load demands at a pre-
adjusted compensator pressure.
At pressures below the
compensator setting, the pump
will operate at maximum
displacement. See model code
on page 4 for compensator pres-
sure ranges.
Warning: The pressure compen-
sator may be adjusted beyond
the rated pressure of the pump.
When adjusting the pressure
limiter, install a 0-350 bar
(0-5000 psi) gage in the outlet
gage port and limit the pressure
setting to the continuous rated
pressure for the pump displace-
ment shown on page 7.
Industrial Pressure Cut-off
Characteristics of Code A
Pressure Compensator
Control at 50°C (120°F), static
conditions.
“K” inlet
gage port
“K” outlet
gage port
“B” inlet
“F” case drain
“C” outlet
To load
See model code on page xx for
spring (pressure) adjustment ranges.
Change in
Pressure A
Pressure Cut-off Characteristics of
Code A Pressure Compensator Control
@ 50ϒC (120ϒF), 1800 r/min, static conditions
Outlet Pressure
Change
in Flow B
Q
P
Outlet Flow
Pressure Cut-off Characteristics of Pressure Compensator Control @ 50°C (120°F), static conditions
“P” Outlet
Max. Speed “Q” Outlet Flow Pressure A B
Model Series r/min l/min (USgpm) bar (psi) bar (psi) L/min (USgpm)
PVM018 1800 32 (8.5) 280 (4000) 2,8 (40) 4,5 (1.2)
PVM020 1800 35 (9.25) 230 (3300) 2,8 (40) 4,5 (1.2)
PVM045 1800 76 (20) 280 (4000) 10 (150) 4,5 (1.2)
PVM050 1800 87 (23) 230 (3300) 10 (150) 4,5 (1.2)
PVM057 1800 102 (27) 280 (4000) 3,5 (51) 14 (3.7)
PVM063 1800 113 (29) 230 (3300) 7,4 (107) 7,6 (2.00)
PVM074 1800 127 (33.5) 280 (4000) 1,5 (22) 37 (9.8)
PVM081 1800 141 (37) 230 (3300) 1,5 (22) 37 (9.8)
PVM098 1800 179 (47) 280 (4000) 1,5 (22) 25 (6.6)
PVM106 1800 195 (51.5) 230 (3300) 1,5 (22) 20 (5.3)
PVM131 1800 229 (60.5) 280 (4000) 3,5 (51) 19 (5.0)
PVM141 1800 238 (63) 230 (3300) 3,5 (51) 14 (3.70)
“K” inlet
gage port
“K” outlet
gage port
“B” inlet
“F” case drain
“C” outlet
To load
See model code on page xx for
spring (pressure) adjustment ranges.
Change in
Pressure A
Pressure Cut-off Characteristics of
Code A Pressure Compensator Control
@ 50°C (120°F), 1800 r/min, static conditions
Outlet Pressure
Change
in Flow B
Q
P
Outlet Flow
13EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Control Options
Mobil Pressure Cut-off
Characteristics of Pressure
Compensator Control at
93°C (200°F), static conditions.
“K” inlet
gage port
“B” inlet
“F” case drain
“C” outlet
To load





See model code on page 5 for
spring (pressure) adjustment ranges.

“K” outlet
gage port
Change in
Pressure A
Outlet Pressure
Outlet Flow
Change
in Flow B
Q
P
+
+
Pressure Cut-off Characteristics of Pressure Compensator Control @ 93°C (200°F), static conditions
“P” Outlet
Rated Speed “Q” Outlet Flow Pressure A B
Model Series r/min l/min (USgpm) bar (psi) bar (psi) L/min (USgpm)
PVM018 2800 42 (11) 280 (4000) 2,8 (40) 4,5 (1.2)
PVM020 2800 52 (14) 230 (3300) 2,8 (41) 4,5 (1.2)
PVM045 2600 115 (30) 280 (4000) 10 (150) 4,5 (1.2)
PVM050 2600 125 (33) 230 (3300) 10 (150) 4,5 (1.2)
PVM057 2500 140 (37) 280 (4000) 3,5 (50) 14 (3.7)
PVM063 2500 159 (42) 230 (3300) 7,4 (107) 11,4 (3.00)
PVM074 2400 174 (46) 280 (4000) 1,5 (20) 37 (9.8)
PVM081 2400 185 (49) 230 (3300) 1,5 (22) 37 (9.8)
PVM098 2200 217 (57) 280 (4000) 1,5 (20) 32 (8.4)
PVM106 2200 234 (62) 230 (3300) 1,5 (22) 24 (6.33)
PVM131 2000 253 (67) 280 (4000) 1,0 (15) 23 (6.0)
PVM141 2000 258 (68) 230 (3300) 7,0 (100) 14 (3.70)
14 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Control Options
Load Sensing and Pressure
Compensator Control
Code B or C
The pump will provide power
matching of pump output to
system load demand, maximiz-
ing efficiency and improving load
metering characteristics of any
directional control valve installed
between the pump and the load.
Load sensing ensures that the
pump always provides only the
amount of ow needed by the
load. At the same time, the
pump operating pressure adjusts
to the actual load pressure plus
a pressure differential required
for the control action. When
the system is not demanding
power, the load sense control
will operate in an energy-saving
stand-by mode.
Typically, the differential pres-
sure is that between the pres-
sure inlet and service port of a
proportionally controlled direc-
tional valve, or a load sensing
directional control valve. See
the model code on page 4 for
differential pressure settings for
load sensing.
If the load pressure exceeds
the system pressure setting,
the pressure compensator de-
strokes the pump. The load
sensing line must be as short as
possible and can also be used
for remote control or unload-
ing of the pump pressure. For
remote control purposes, it is
recommended that you contact
your Eaton representative for
the correct configuration of the
control.
Warning: The pressure com-
pensator may be adjusted
beyond the rated pressure of
the pump. When adjusting the
pressure limiter, install a
0-350 bar (0-5000 psi) gage
in the outlet gage port and
limit the pressure setting to the
continuous rated pressure for
the pump displacement shown
on page 7.
“K” outlet
gage port
“B” inlet
“F” case drain
“C” outlet
To load
“J” load
sense
signal
port
Optional bleed-down orifice in Code B
control.0,4 mm (.016 in.) Orifice is plugged
for no bleed down in control Code C.
“K” inlet
gage port
15EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Control Options
Inlet
Case drain
Outlet
To load
Load sense
signal port
Tank port
Pressure
port
Inlet
Case drain
Outlet
To load
Load sense
signal port
Tank port
Pressure
port
Inlet
Case drain
Outlet
To load
Load sense
signal port
Tank port
Pressure
port
Inlet
Case drain
Outlet
To load
Load sense
signal port
Tank port
Pressure
port
This pump is intended for use
when multiple, remote, or elec-
tronically controlled compensat-
ing settings, with or without
load sensing, are desired.
Pressure compensation is
obtained when an internal plug
is removed, the load-sense
signal port is kept plugged, and
internal pilot pressure is applied
to the spring chamber of the
control spool. For pressure
compensation with load sensing,
the internal plug stays, the load-
sense signal port is unplugged,
and pilot pressure is externally
applied.
An external relief valve (not
supplied) controls spring cham-
ber pressure. The externally
adjustable spring determines
the differential pressure setting
of the control. Outlet pressure
is limited to the valve of the
spring chamber (pressure port)
pressure, plus control differential
pressure.
Spring chamber (pilot) pres-
sure is separated from outlet
pressure by an internal orifice.
Outlet pressure shifts the spool
when pressure drop across the
orifice reaches the differential
pressure setting, and the pump
de-strokes.
The relief valve can be mounted
to an NFPA-D03/ISO 4401-03
pad on the pump control, or
remotely located via tapping and
blanking plates installed on the
pad. See “Ordering Procedure”,
page 27, for more on valves and
plates.
The standard factory-set dif-
ferential pressure setting of
the pump control is 20 bar (290
psi) and is not specified in the
pump model number. Any other
ordered differential pressure,
within the control’s adjustable
pressure range of 17-35 bar
(247-508 psi), will be specified in
the model number.
Industrial Control
Compensator – Code E & F
(Model 057-141 only)
With Pressure & Flow Compensator (E)
Pressure Compensating Without Load Sensing (F)
16 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance
Industrial
PVM018
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
Noise Level – dBA
Noise Level – dBA
46
50
52
56
60
66
48
54
58
64
62
44
46
50
54
60
62
42
48
52
58
56
1800 r/min
min. flow
1200 r/min
max. flow
1800 r/min
max. flow
Typical Noise Levels at 1800 and 1200 r/min with
Petroleum Oil (10W) at 50°C (120°F) and 1.0 bar
absolute (0 psi gauge) Inlet
Typical Noise Levels at 1500 and 1000 r/min with
Petroleum Oil (10W) at 50°C (120°F) and 1.0 bar
absolute (0 psi gauge) Inlet
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
Sound pressure data
equivalent to NFPA.
1200 r/min
min. flow
1000 r/min
min. flow
1000 r/min
max. flow
1500 r/min
min. flow
1500 r/min
max. flow
100 (885)
90 (796)
80 (708)
70 (619)
60 (531)
50 (442)
40 (354)
30 (265)
20 (177)
10 (88)
0
Input Torque – Nm (in-lb)
20 (27)
15 (20)
10 (13)
5 (7)
0
Input Power – kW (hp)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Input Torque,
Cut-off
Input Torque and Power at 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0
100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
40 (11)
30 (8)
20 (5)
10 (3)
0
Delivery – l/min (USgpm)
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
Noise Level – dBA
Noise Level – dBA
46
50
52
56
60
66
48
54
58
64
62
44
46
50
54
60
62
42
48
52
58
56
1800 r/min
min. flow
1200 r/min
max. flow
1800 r/min
max. flow
Typical Noise Levels at 1800 and 1200 r/min with
Petroleum Oil (10W) at 50°C (120°F) and 1.0 bar
absolute (0 psi gauge) Inlet
Typical Noise Levels at 1500 and 1000 r/min with
Petroleum Oil (10W) at 50°C (120°F) and 1.0 bar
absolute (0 psi gauge) Inlet
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
Sound pressure data
equivalent to NFPA.
1200 r/min
min. flow
1000 r/min
min. flow
1000 r/min
max. flow
1500 r/min
min. flow
1500 r/min
max. flow
100 (885)
90 (796)
80 (708)
70 (619)
60 (531)
50 (442)
40 (354)
30 (265)
20 (177)
10 (88)
0
Input Torque – Nm (in-lb)
20 (27)
15 (20)
10 (13)
5 (7)
0
Input Power – kW (hp)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Input Torque,
Cut-off
Input Torque and Power at 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0
100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
40 (11)
30 (8)
20 (5)
10 (3)
0
Delivery – l/min (USgpm)
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
17EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance
Industrial
PVM018
100
90
80
70
60
50
40
30
20
10
0
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
Input Torque – Nm (in.lb.)
Efficiency – %
Delivery – l/min (USgpm)
Input Power – kW (hp)
Delivery and Efficiency at 1500 r/min
50°C (120° F) and 1.0 bar absolute (0 psi gauge) Inlet
30 (8)
20 (5)
10 (3)
0
Volumetric Efficiency
Delivery (effective flow)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Input Torque and Power at 1500 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0
100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
100 (885)
90 (796)
80 (708)
70 (619)
60 (531)
50 (442)
40 (354)
30 (265)
20 (177)
10 (88)
0
20 (27)
15 (20)
10 (13)
5 (7)
0
Overall Efficiency
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
30 (8)
20 (5)
10 (3)
0
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Input Torque and Power at 1200 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
100 (885)
90 (796)
80 (708)
70 (619)
60 (531)
50 (442)
40 (354)
30 (265)
20 (177)
10 (88)
0
20 (27)
15 (20)
10 (13)
5 (7)
0
100
90
80
70
60
50
40
30
20
10
0
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
Input Torque – Nm (in.lb.)
Efficiency – %
Delivery – l/min (USgpm)
Input Power – kW (hp)
Delivery and Efficiency at 1500 r/min
50°C (120° F) and 1.0 bar absolute (0 psi gauge) Inlet
30 (8)
20 (5)
10 (3)
0
Volumetric Efficiency
Delivery (effective flow)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Input Torque and Power at 1500 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0
100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
100 (885)
90 (796)
80 (708)
70 (619)
60 (531)
50 (442)
40 (354)
30 (265)
20 (177)
10 (88)
0
20 (27)
15 (20)
10 (13)
5 (7)
0
Overall Efficiency
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
30 (8)
20 (5)
10 (3)
0
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Input Torque and Power at 1200 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
100 (885)
90 (796)
80 (708)
70 (619)
60 (531)
50 (442)
40 (354)
30 (265)
20 (177)
10 (88)
0
20 (27)
15 (20)
10 (13)
5 (7)
0
18 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance
Industrial
PVM018
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
Efficiency – %
Delivery – l/min (USgpm)
Input to0rque – Nm (in.lb.)
Input Power – kW (hp)
Delivery and Efficiency at 1000 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
20 (5)
10 (3)
0
Volumetric Efficiency
Delivery (effective flow)
0
100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Input Torque and Power at 1000 r/min
50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
Overall Efficiency
100 (885)
90 (796)
80 (708)
70 (619)
60 (531)
50 (442)
40 (354)
30 (265)
20 (177)
10 (88)
0
20 (27)
15 (20)
10 (13)
5 (7)
0
5 (1.32)
4 (1.06)
3 (0.79)
2 (0.53)
1 (0.26)
0
1,4 (0.37)
1,2 (0.32)
1,0 (0.26)
0,8 (0.21)
0,6 (0.16)
0,4 (0.11)
0,2 (0.05)
0
Case Flow – l/min (USgpm)
Case Flow Versus Outlet Pressure at 1800 r/min, Full Flow
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Case Flow – l/min (USgpm)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
Efficiency – %
Delivery – l/min (USgpm)
Input to0rque – Nm (in.lb.)
Input Power – kW (hp)
Delivery and Efficiency at 1000 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
20 (5)
10 (3)
0
Volumetric Efficiency
Delivery (effective flow)
0
100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Input Torque and Power at 1000 r/min
50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
Overall Efficiency
100 (885)
90 (796)
80 (708)
70 (619)
60 (531)
50 (442)
40 (354)
30 (265)
20 (177)
10 (88)
0
20 (27)
15 (20)
10 (13)
5 (7)
0
5 (1.32)
4 (1.06)
3 (0.79)
2 (0.53)
1 (0.26)
0
1,4 (0.37)
1,2 (0.32)
1,0 (0.26)
0,8 (0.21)
0,6 (0.16)
0,4 (0.11)
0,2 (0.05)
0
Case Flow – l/min (USgpm)
Case Flow Versus Outlet Pressure at 1800 r/min, Full Flow
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Case Flow – l/min (USgpm)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
19EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance
Mobile
PVM018
76
72
68
64
60
56
52
48
44
40
Noise Level – dBA
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
Outlet Pressure – bar (psi)
(Sound pressure data equivalent to NFPA)
600 r/min
Min. Flow
600 r/min
Max. Flow
2800 r/min
Min. Flow
2800 r/min
Max. Flow
350
(5000)
Typical Noise Levels
Petroleum Oil (10W) at 93°C (200°F),
1.0 bar absolute (0 psi gauge) Inlet
0 500 1000 1500 2000 2500 3000
Efficiency – %
Speed – r/min
200 bar
(2900 psi)
100 bar
(1500 psi)
320 bar
(4600 psi)
280 bar
(4000 psi)
150 bar
(2200 psi)
95
90
85
80
75
70
Overall Efficiency Versus Speed
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
250 bar
(3600 psi)
76
72
68
64
60
56
52
48
44
40
Noise Level – dBA
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
Outlet Pressure – bar (psi)
(Sound pressure data equivalent to NFPA)
600 r/min
Min. Flow
600 r/min
Max. Flow
2800 r/min
Min. Flow
2800 r/min
Max. Flow
350
(5000)
Typical Noise Levels
Petroleum Oil (10W) at 93°C (200°F),
1.0 bar absolute (0 psi gauge) Inlet
0 500 1000 1500 2000 2500 3000
Efficiency – %
Speed – r/min
200 bar
(2900 psi)
100 bar
(1500 psi)
320 bar
(4600 psi)
280 bar
(4000 psi)
150 bar
(2200 psi)
95
90
85
80
75
70
Overall Efficiency Versus Speed
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
250 bar
(3600 psi)
40 (10.6)
20 (5.3)
0
0 500 1000 1500 2000 2500
1,0 (.3)
3,0 (.8)
4,0 (1.1)
Speed – r/min
Delivery – l/min (USgpm)
Input Torque – Nm (in.lb.)
Case Flow – l/min (USgpm)
25 bar (365 psi),
Delivery
250 bar (3600 psi),
Delivery
25 bar (365 psi), Case flow
10 (2.6)
30 (7.9)
50 (13.2)
0
3000
35 (9.2)
15 (4.0)
5 (1.3)
25 (5.3)
45 (11.9)
2,0 (.5)
Delivery and Case Flow Versus Speed
@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi) gauge Inlet
Input Torque Versus Speed
@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi gauge) inlet
Speed – r/min
0
0 500 1000 1500 2000 2500
25 bar (365 psi)
250 bar (3600 psi)
150 bar (2200 psi)
200 bar (2900 psi)
280 bar (4000 psi)
3000
90 (796)
10 (88)
100 bar (1500 psi)
50 (442)
20 (177)
40 (354)
30 (265)
110 (973)
60 (531)
70 (619)
100 (885)
80 (708)
320 bar (4600 psi)
250 bar (3600 psi), Case flow
40 (10.6)
20 (5.3)
0
0 500 1000 1500 2000 2500
1,0 (.3)
3,0 (.8)
4,0 (1.1)
Speed – r/min
Delivery – l/min (USgpm)
Input Torque – Nm (in.lb.)
Case Flow – l/min (USgpm)
25 bar (365 psi),
Delivery
250 bar (3600 psi),
Delivery
25 bar (365 psi), Case flow
10 (2.6)
30 (7.9)
50 (13.2)
0
3000
35 (9.2)
15 (4.0)
5 (1.3)
25 (5.3)
45 (11.9)
2,0 (.5)
Delivery and Case Flow Versus Speed
@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi) gauge Inlet
Input Torque Versus Speed
@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi gauge) inlet
Speed – r/min
0
0 500 1000 1500 2000 2500
25 bar (365 psi)
250 bar (3600 psi)
150 bar (2200 psi)
200 bar (2900 psi)
280 bar (4000 psi)
3000
90 (796)
10 (88)
100 bar (1500 psi)
50 (442)
20 (177)
40 (354)
30 (265)
110 (973)
60 (531)
70 (619)
100 (885)
80 (708)
320 bar (4600 psi)
250 bar (3600 psi), Case flow
20 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance
Mobile
PVM018
0 500 1000 1500 2000 2500 3000
Input Power @ Full Flow – kW (hp)
Speed – r/min
280 bar
(4000 psi)
250 bar
(3600 psi)
200 bar
(2900 psi)
150 bar
(2200 psi)
100 bar
(1500 psi)
25 bar
(365 psi)
320 bar
(4600 psi)
28 (37.5)
24 (32.2)
20 (26.8)
16 (21.4)
12 (16.1)
8 (10.7)
4 (5.4)
2 (2.7)
6 (8.0)
10 (13.4)
14 (18.8)
18 (24.1)
22 (29.5)
26 (34.9)
0
Input Power Versus Speed
@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi gauge) inlet
20 bar (300 psi)
differential,
Case Flow
0 500 1000 1500 2000 2500 3000
20 bar (300 psi)
differential,
Input Torque
11 bar (160 psi)
differential,
Input Torque
11 bar (160 psi)
differential,
Case Flow
Input Torque and Case Flow Versus Speed
@ 93°C (200°F), load sense standby
and 1.0 bar absolute (0 psi gauge) inlet
Speed – r/min
Input Torque - Nm (in.lb.)
Case Flow (l/min (USgpm)
2 (0.53)
4 (1.06)
2 (18)
3 (27)
1 (9)
5 (1.32)
1 (0.26)
3 (0.79)
0
0
0 500 1000 1500 2000 2500 3000
Input Power @ Full Flow – kW (hp)
Speed – r/min
280 bar
(4000 psi)
250 bar
(3600 psi)
200 bar
(2900 psi)
150 bar
(2200 psi)
100 bar
(1500 psi)
25 bar
(365 psi)
320 bar
(4600 psi)
28 (37.5)
24 (32.2)
20 (26.8)
16 (21.4)
12 (16.1)
8 (10.7)
4 (5.4)
2 (2.7)
6 (8.0)
10 (13.4)
14 (18.8)
18 (24.1)
22 (29.5)
26 (34.9)
0
Input Power Versus Speed
@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi gauge) inlet
20 bar (300 psi)
differential,
Case Flow
0 500 1000 1500 2000 2500
3000
20 bar (300 psi)
differential,
Input Torque
11 bar (160 psi)
differential,
Input Torque
11 bar (160 psi)
differential,
Case Flow
Input Torque and Case Flow Versus Speed
@ 93°C (200°F), load sense standby
and 1.0 bar absolute (0 psi gauge) inlet
Speed – r/min
Input Torque - Nm (in.lb.)
Case Flow (l/min (USgpm)
2 (0.53)
4 (1.06)
2 (18)
3 (27)
1 (9)
5 (1.32)
1 (0.26)
3 (0.79)
0
0
40 (354)
0
0 500 1000 1500 2000 2500
0
Input Torque – Nm (in.lb.)
Speed – r/min
280 bar (4000 psi)
Input Torque
150 bar (2200 psi)
Input Torque
280 bar (4000 psi), Case Flow
150 bar (2200 psi)
Case Flow
10 (88)
20 (177)
30 (265)
50 (442)
5 (45)
15 (135)
25 (221)
35 (310)
45 (398)
Input Torque and Case Flow Versus Speed
@ 93°C (200°F), cut-off and 1.0 bar absolute
(0 psi gauge) inlet
3 (0.8)
6 (1.6)
9 (2.4)
21EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
Delivery – l/min (USgpm)
Efficiency – %
Efficiency – %
Input Power – kW (hp)
Input torque – Nm (in.lb.)
Input torque – Nm (in.lb.)
Delivery and Efficiency at 1800 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
00
10 (3)
20 (5)
30 (8)
40 (11)
50 (13)
10 (3)
20 (5)
30 (8)
40 (11)
50 (13)
0
10
20
30
40
50
60
70
80
90
100
Delivery and Efficiency at 1500 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
Volumetric Efficiency
Overall Efficiency
0
10
20
30
40
50
60
70
80
90
100
0
100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
0
100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque and Power at 1800 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
Input Power – kW (hp)
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
0
10 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
90 (796)
100 (885)
110 (973)
120 (1062)
0
10 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
90 (796)
100 (885)
110 (973)
120 (1062)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Input Torque and Power at 1500 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
Input Power,
Full Stroke
Input Torque,
Full Stroke
Delivery (effective flow)
Input Torque,
Cut off
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
Delivery – l/min (USgpm)
Efficiency – %
Efficiency – %
Input Power – kW (hp)
Input torque – Nm (in.lb.)
Input torque – Nm (in.lb.)
Delivery and Efficiency at 1800 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
00
10 (3)
20 (5)
30 (8)
40 (11)
50 (13)
10 (3)
20 (5)
30 (8)
40 (11)
50 (13)
0
10
20
30
40
50
60
70
80
90
100
Delivery and Efficiency at 1500 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
Volumetric Efficiency
Overall Efficiency
0
10
20
30
40
50
60
70
80
90
100
0
100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
0
100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque and Power at 1800 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
Input Power – kW (hp)
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
0
10 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
90 (796)
100 (885)
110 (973)
120 (1062)
0
10 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
90 (796)
100 (885)
110 (973)
120 (1062)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Input Torque and Power at 1500 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
Input Power,
Full Stroke
Input Torque,
Full Stroke
Delivery (effective flow)
Input Torque,
Cut off
Performance
Industrial
PVM020
62
64
60
58
56
54
52
50
48
46
44
42
40
Typical Noise Levels at 1800 and 1200 r/min
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
Noise Level – dBA Noise Level – dBA
1500 r/min
Max. Flow
1500 r/min
Min. Flow
1000 r/min
Max. Flow
1000 r/min
Min. Flow
Sound pressure data
equivalent to NFPA
Typical Noise Levels at 1500 and 1000 r/min
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
62
64
60
58
56
54
52
50
48
46
44
42
40
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
1800 r/min
Max. Flow
1800 r/min
Min. Flow
1200 r/min
Min. Flow
1200 r/min
Max. Flow
62
64
60
58
56
54
52
50
48
46
44
42
40
Typical Noise Levels at 1800 and 1200 r/min
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
Noise Level – dBA Noise Level – dBA
1500 r/min
Max. Flow
1500 r/min
Min. Flow
1000 r/min
Max. Flow
1000 r/min
Min. Flow
Sound pressure data
equivalent to NFPA
Typical Noise Levels at 1500 and 1000 r/min
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
62
64
60
58
56
54
52
50
48
46
44
42
40
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
1800 r/min
Max. Flow
1800 r/min
Min. Flow
1200 r/min
Min. Flow
1200 r/min
Max. Flow
22 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance
Industrial
PVM020
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
Delivery – l/min (USgpm)
Efficiency – %
Efficiency – %
Input Power – kW (hp)
Input torque – Nm (in.lb.)
Input torque – Nm (in.lb.)
Delivery and Efficiency at 1800 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
00
10 (3)
20 (5)
30 (8)
40 (11)
50 (13)
10 (3)
20 (5)
30 (8)
40 (11)
50 (13)
0
10
20
30
40
50
60
70
80
90
100
Delivery and Efficiency at 1500 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
Volumetric Efficiency
Overall Efficiency
0
10
20
30
40
50
60
70
80
90
100
0
100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
0
100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque and Power at 1800 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
Input Power – kW (hp)
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
0
10 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
90 (796)
100 (885)
110 (973)
120 (1062)
0
10 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
90 (796)
100 (885)
110 (973)
120 (1062)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Input Torque and Power at 1500 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
Input Power,
Full Stroke
Input Torque,
Full Stroke
Delivery (effective flow)
Input Torque,
Cut off
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
Delivery – l/min (USgpm)
Efficiency – %
Efficiency – %
Input Power – kW (hp)
Input torque – Nm (in.lb.)
Input torque – Nm (in.lb.)
Delivery and Efficiency at 1800 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
00
10 (3)
20 (5)
30 (8)
40 (11)
50 (13)
10 (3)
20 (5)
30 (8)
40 (11)
50 (13)
0
10
20
30
40
50
60
70
80
90
100
Delivery and Efficiency at 1500 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
Volumetric Efficiency
Overall Efficiency
0
10
20
30
40
50
60
70
80
90
100
0
100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
0
100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque and Power at 1800 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
Input Power – kW (hp)
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
0
10 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
90 (796)
100 (885)
110 (973)
120 (1062)
0
10 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
90 (796)
100 (885)
110 (973)
120 (1062)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Input Torque and Power at 1500 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
Input Power,
Full Stroke
Input Torque,
Full Stroke
Delivery (effective flow)
Input Torque,
Cut off
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
Delivery – l/min (USgpm)
Efficiency – %
Efficiency – %
Input Power – kW (hp)
Input torque – Nm (in.lb.)
Input torque – Nm (in.lb.)
Delivery and Efficiency at 1200 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
10 (3)
20 (5)
30 (8)
40 (11)
50 (13)
10 (3)
20 (5)
30 (8)
40 (11)
50 (13)
0
10
20
30
40
50
60
70
80
90
100
Delivery and Efficiency at 1000 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
Volumetric Efficiency
Overall Efficiency
0
10
20
30
40
50
60
70
80
90
100
0
100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
0
100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque and Power at 1200 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
Input Power – kW (hp)
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
0
10 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
90 (796)
100 (885)
110 (973)
120 (1062)
0
10 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
90 (796)
100 (885)
110 (973)
120 (1062)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Input Torque and Power at 1000 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
Input Power,
Full Stroke
Input Torque,
Full Stroke
Delivery (effective flow)
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
Delivery – l/min (USgpm)
Efficiency – %
Efficiency – %
Input Power – kW (hp)
Input torque – Nm (in.lb.)
Input torque – Nm (in.lb.)
Delivery and Efficiency at 1200 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
10 (3)
20 (5)
30 (8)
40 (11)
50 (13)
10 (3)
20 (5)
30 (8)
40 (11)
50 (13)
0
10
20
30
40
50
60
70
80
90
100
Delivery and Efficiency at 1000 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
Volumetric Efficiency
Overall Efficiency
0
10
20
30
40
50
60
70
80
90
100
0
100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
0
100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque and Power at 1200 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
Input Power – kW (hp)
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
0
10 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
90 (796)
100 (885)
110 (973)
120 (1062)
0
10 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
90 (796)
100 (885)
110 (973)
120 (1062)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Input Torque and Power at 1000 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
Input Power,
Full Stroke
Input Torque,
Full Stroke
Delivery (effective flow)
23EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Case Flow l/min – (USgpm)
Outlet Pressure – bar (psi)
Case Flow versus Outlet Pressure at 1800 r/min, Full Flow,
50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
0.3 (0.07)
0.5 (0.13)
0.8 (0.20)
1.0 (0.26)
1.3 (0.33)
1.5 (0.40)
1.8 (0.46)
2.0 (0.53)
2.3 (0.59)
2.5 (0.66)
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Case Flow l/min – (USgpm)
Outlet Pressure – bar (psi)
0
1 (0.26)
2 (0.53)
3 (0.79)
4 (1.06)
5 (1.32)
6 (1.59)
7 (1.85)
8 (2.11)
9 (2.38)
10 (2.64)
Case Flow versus Outlet Pressure at Cutoff, 1800 r/min,
50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Case Flow l/min – (USgpm)
Outlet Pressure – bar (psi)
Case Flow versus Outlet Pressure at 1800 r/min, Full Flow,
50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
0.3 (0.07)
0.5 (0.13)
0.8 (0.20)
1.0 (0.26)
1.3 (0.33)
1.5 (0.40)
1.8 (0.46)
2.0 (0.53)
2.3 (0.59)
2.5 (0.66)
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Case Flow l/min – (USgpm)
Outlet Pressure – bar (psi)
0
1 (0.26)
2 (0.53)
3 (0.79)
4 (1.06)
5 (1.32)
6 (1.59)
7 (1.85)
8 (2.11)
9 (2.38)
10 (2.64)
Case Flow versus Outlet Pressure at Cutoff, 1800 r/min,
50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
Performance
Industrial
PVM020
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
Delivery – l/min (USgpm)
Efficiency – %
Efficiency – %
Input Power – kW (hp)
Input torque – Nm (in.lb.)
Input torque – Nm (in.lb.)
Delivery and Efficiency at 1200 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
10 (3)
20 (5)
30 (8)
40 (11)
50 (13)
10 (3)
20 (5)
30 (8)
40 (11)
50 (13)
0
10
20
30
40
50
60
70
80
90
100
Delivery and Efficiency at 1000 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
Volumetric Efficiency
Overall Efficiency
0
10
20
30
40
50
60
70
80
90
100
0
100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
0
100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque and Power at 1200 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
Input Power – kW (hp)
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
0
10 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
90 (796)
100 (885)
110 (973)
120 (1062)
0
10 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
90 (796)
100 (885)
110 (973)
120 (1062)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Input Torque and Power at 1000 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
Input Power,
Full Stroke
Input Torque,
Full Stroke
Delivery (effective flow)
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
Delivery – l/min (USgpm)
Efficiency – %
Efficiency – %
Input Power – kW (hp)
Input torque – Nm (in.lb.)
Input torque – Nm (in.lb.)
Delivery and Efficiency at 1200 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
10 (3)
20 (5)
30 (8)
40 (11)
50 (13)
10 (3)
20 (5)
30 (8)
40 (11)
50 (13)
0
10
20
30
40
50
60
70
80
90
100
Delivery and Efficiency at 1000 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
Volumetric Efficiency
Overall Efficiency
0
10
20
30
40
50
60
70
80
90
100
0
100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
0
100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque and Power at 1200 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
Input Power – kW (hp)
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
0
10 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
90 (796)
100 (885)
110 (973)
120 (1062)
0
10 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
90 (796)
100 (885)
110 (973)
120 (1062)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Input Torque and Power at 1000 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
Input Power,
Full Stroke
Input Torque,
Full Stroke
Delivery (effective flow)
24 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance
Mobile
PVM020
Sound pressure data
equivalent to NFPA.
Noise Level – dBA
Typical Noise Levels at 2800 & 600 r/min with Petroleum Oil (10W)
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
41
47
56
62
68
74
44
53
59
65
71
50
77
2800 r/min
max. flow
600 r/min
min. flow
Outlet Pressure – bar (psi)
Overall Efficiency (%)
Overall Efficiency versus Speed
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet
0 500 1000 1500 2000 2500
Speed – r/min
50
60
75
85
95
55
70
80
90
65
100
3000
100 bar (1500 psi)
150 bar
(2200 psi)
230 bar (3300 psi)
210 bar (3000 psi)
50 bar (700 psi)
Delivery and Case Flow versus Speed at 93°C (200°F),
Full Flow 1.0 bar absolute (0 psi gauge) inlet
0
Speed (r/min)
Delivery – l/min (USgpm)
20 (5.3)
30 (7.9)
40 (10.6)
50 (13.2)
55 (14.5)
500 1000 1500 2000 2500
15 (4.0)
25 (6.6)
35 (9.2)
45 (11.9)
60 (15.9)
10 (2.6)
5 (1.3)
Case Flow – l/min (USgpm)
4 (1.06)
3 (0.79)
2 (0.53)
1 (0.26)
0
3000
50 bar (725
psi) Delivery
210 bar (3000 psi) Case Flow
50 bar (725 psi) Case Flow
210 bar (3000
psi) Delivery
600 r/min
max. flow
2800 r/min
min. flow
Sound pressure data
equivalent to NFPA.
Noise Level – dBA
Typical Noise Levels at 2800 & 600 r/min with Petroleum Oil (10W)
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
41
47
56
62
68
74
44
53
59
65
71
50
77
2800 r/min
max. flow
600 r/min
min. flow
Outlet Pressure – bar (psi)
Overall Efficiency (%)
Overall Efficiency versus Speed
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet
0 500 1000 1500 2000 2500
Speed – r/min
50
60
75
85
95
55
70
80
90
65
100
3000
100 bar (1500 psi)
150 bar
(2200 psi)
230 bar (3300 psi)
210 bar (3000 psi)
50 bar (700 psi)
Delivery and Case Flow versus Speed at 93°C (200°F),
Full Flow 1.0 bar absolute (0 psi gauge) inlet
0
Speed (r/min)
Delivery – l/min (USgpm)
20 (5.3)
30 (7.9)
40 (10.6)
50 (13.2)
55 (14.5)
500 1000 1500 2000 2500
15 (4.0)
25 (6.6)
35 (9.2)
45 (11.9)
60 (15.9)
10 (2.6)
5 (1.3)
Case Flow – l/min (USgpm)
4 (1.06)
3 (0.79)
2 (0.53)
1 (0.26)
0
3000
50 bar (725
psi) Delivery
210 bar (3000 psi) Case Flow
50 bar (725 psi) Case Flow
210 bar (3000
psi) Delivery
600 r/min
max. flow
2800 r/min
min. flow
Sound pressure data
equivalent to NFPA.
Noise Level – dBA
Typical Noise Levels at 2800 & 600 r/min with Petroleum Oil (10W)
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
41
47
56
62
68
74
44
53
59
65
71
50
77
2800 r/min
max. flow
600 r/min
min. flow
Outlet Pressure – bar (psi)
Overall Efficiency (%)
Overall Efficiency versus Speed
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet
0 500 1000 1500 2000 2500
Speed – r/min
50
60
75
85
95
55
70
80
90
65
100
3000
100 bar (1500 psi)
150 bar
(2200 psi)
230 bar (3300 psi)
210 bar (3000 psi)
50 bar (700 psi)
Delivery and Case Flow versus Speed at 93°C (200°F),
Full Flow 1.0 bar absolute (0 psi gauge) inlet
0
Speed (r/min)
Delivery – l/min (USgpm)
20 (5.3)
30 (7.9)
40 (10.6)
50 (13.2)
55 (14.5)
500 1000 1500 2000 2500
15 (4.0)
25 (6.6)
35 (9.2)
45 (11.9)
60 (15.9)
10 (2.6)
5 (1.3)
Case Flow – l/min (USgpm)
4 (1.06)
3 (0.79)
2 (0.53)
1 (0.26)
0
3000
50 bar (725
psi) Delivery
210 bar (3000 psi) Case Flow
50 bar (725 psi) Case Flow
210 bar (3000
psi) Delivery
600 r/min
max. flow
2800 r/min
min. flow
25EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance
Mobile
PVM020
0 1000500 20001500
Speed (r/min)
2500
Input Torque – Nm (lb.in.)
Input Torque versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
100 (885)
110 (973)
3000
230 bar (3300 psi)
210 bar (3000 psi)
150 bar (2200 psi)
90 (796)
50 bar (725 psi)
100 bar (1500 psi)
0 1000500 20001500
Speed (r/min)
2500
Input Power – kW (hp)
0
2 (3)
4 (5)
6 (8)
8 (11)
10 (13)
12 (16)
14 (19)
16 (21)
18 (24)
20 (27)
22 (30)
24 (32)
Input Power versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
230 bar (3300 psi)
210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
50 bar (725 psi)
Input Torque and Case Flow versus Speed at
93°C (200°F), Load Sense Standby and 1.0 bar
absolute (0 psi gauge) Inlet
0
Speed (r/min)
Input Torque – Nm (lb.in.)
.8 (7)
1.2 (11)
1.4 (12)
1.6 (14)
1.8 (16)
500 1000 1500 2000 2500
.4 (4)
3.0 (.79)
2.0 (.53)
1.0 (.26)
0
3000
2 (18)
2.2 (19)
Case Flow
l/min
(USgpm)
5.0 (1.32)
4.0 (1.06)
.2 (2)
.6 (5)
1 (9)
2.4 (21)
2.6 (23)
2.8 (25)
3.0 (27)
3.2 (28)
20 bar (290 psi) diff.
Input Torque
11 bar (160 psi) diff.
Input Torque
11 bar (160 psi) diff.
Case Flow
20 bar (290 psi) diff.
Case Flow
0
Input Torque and Case Flow versus Speed
at 93°C (200°F), Pressure Limit Cut-off and
1.0 bar absolute (0 psi gauge) Inlet
6 (53)
12 (106)
18 (159)
24 (212)
500 1000 1500 2000 2500 3000
3 (27)
9 (80)
15 (133)
21 (186)
27 (239)
Input Torque – Nm (lb.in.)
30 (265)
Speed (r/min)
9 (2.4)
Case
Flow l/min
(USgpm)
6 (1.6)
3 (0.8)
150 bar
(2200 psi)
Input Torque
210 bar (3000 psi)
Input Torque
210 bar (3000 psi) Case Flow
150 bar (2200 psi) Case Flow
0 1000500 20001500
Speed (r/min)
2500
Input Torque – Nm (lb.in.)
Input Torque versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
100 (885)
110 (973)
3000
230 bar (3300 psi)
210 bar (3000 psi)
150 bar (2200 psi)
90 (796)
50 bar (725 psi)
100 bar (1500 psi)
0 1000500 20001500
Speed (r/min)
2500
Input Power – kW (hp)
0
2 (3)
4 (5)
6 (8)
8 (11)
10 (13)
12 (16)
14 (19)
16 (21)
18 (24)
20 (27)
22 (30)
24 (32)
Input Power versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
230 bar (3300 psi)
210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
50 bar (725 psi)
Input Torque and Case Flow versus Speed at
93°C (200°F), Load Sense Standby and 1.0 bar
absolute (0 psi gauge) Inlet
0
Speed (r/min)
Input Torque – Nm (lb.in.)
.8 (7)
1.2 (11)
1.4 (12)
1.6 (14)
1.8 (16)
500 1000 1500 2000 2500
.4 (4)
3.0 (.79)
2.0 (.53)
1.0 (.26)
0
3000
2 (18)
2.2 (19)
Case Flow
l/min
(USgpm)
5.0 (1.32)
4.0 (1.06)
.2 (2)
.6 (5)
1 (9)
2.4 (21)
2.6 (23)
2.8 (25)
3.0 (27)
3.2 (28)
20 bar (290 psi) diff.
Input Torque
11 bar (160 psi) diff.
Input Torque
11 bar (160 psi) diff.
Case Flow
20 bar (290 psi) diff.
Case Flow
0
Input Torque and Case Flow versus Speed
at 93°C (200°F), Pressure Limit Cut-off and
1.0 bar absolute (0 psi gauge) Inlet
6 (53)
12 (106)
18 (159)
24 (212)
500 1000 1500 2000 2500 3000
3 (27)
9 (80)
15 (133)
21 (186)
27 (239)
Input Torque – Nm (lb.in.)
30 (265)
Speed (r/min)
9 (2.4)
Case
Flow l/min
(USgpm)
6 (1.6)
3 (0.8)
150 bar
(2200 psi)
Input Torque
210 bar (3000 psi)
Input Torque
210 bar (3000 psi) Case Flow
150 bar (2200 psi) Case Flow
0 1000500 20001500
Speed (r/min)
2500
Input Torque – Nm (lb.in.)
Input Torque versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
100 (885)
110 (973)
3000
230 bar (3300 psi)
210 bar (3000 psi)
150 bar (2200 psi)
90 (796)
50 bar (725 psi)
100 bar (1500 psi)
0 1000500 20001500
Speed (r/min)
2500
Input Power – kW (hp)
0
2 (3)
4 (5)
6 (8)
8 (11)
10 (13)
12 (16)
14 (19)
16 (21)
18 (24)
20 (27)
22 (30)
24 (32)
Input Power versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
230 bar (3300 psi)
210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
50 bar (725 psi)
Input Torque and Case Flow versus Speed at
93°C (200°F), Load Sense Standby and 1.0 bar
absolute (0 psi gauge) Inlet
0
Speed (r/min)
Input Torque – Nm (lb.in.)
.8 (7)
1.2 (11)
1.4 (12)
1.6 (14)
1.8 (16)
500 1000 1500 2000 2500
.4 (4)
3.0 (.79)
2.0 (.53)
1.0 (.26)
0
3000
2 (18)
2.2 (19)
Case Flow
l/min
(USgpm)
5.0 (1.32)
4.0 (1.06)
.2 (2)
.6 (5)
1 (9)
2.4 (21)
2.6 (23)
2.8 (25)
3.0 (27)
3.2 (28)
20 bar (290 psi) diff.
Input Torque
11 bar (160 psi) diff.
Input Torque
11 bar (160 psi) diff.
Case Flow
20 bar (290 psi) diff.
Case Flow
0
Input Torque and Case Flow versus Speed
at 93°C (200°F), Pressure Limit Cut-off and
1.0 bar absolute (0 psi gauge) Inlet
6 (53)
12 (106)
18 (159)
24 (212)
500 1000 1500 2000 2500 3000
3 (27)
9 (80)
15 (133)
21 (186)
27 (239)
Input Torque – Nm (lb.in.)
30 (265)
Speed (r/min)
9 (2.4)
Case
Flow l/min
(USgpm)
6 (1.6)
3 (0.8)
150 bar
(2200 psi)
Input Torque
210 bar (3000 psi)
Input Torque
210 bar (3000 psi) Case Flow
150 bar (2200 psi) Case Flow
0 1000500 20001500
Speed (r/min)
2500
Input Torque – Nm (lb.in.)
Input Torque versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
100 (885)
110 (973)
3000
230 bar (3300 psi)
210 bar (3000 psi)
150 bar (2200 psi)
90 (796)
50 bar (725 psi)
100 bar (1500 psi)
0 1000500 20001500
Speed (r/min)
2500
Input Power – kW (hp)
0
2 (3)
4 (5)
6 (8)
8 (11)
10 (13)
12 (16)
14 (19)
16 (21)
18 (24)
20 (27)
22 (30)
24 (32)
Input Power versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
230 bar (3300 psi)
210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
50 bar (725 psi)
Input Torque and Case Flow versus Speed at
93°C (200°F), Load Sense Standby and 1.0 bar
absolute (0 psi gauge) Inlet
0
Speed (r/min)
Input Torque – Nm (lb.in.)
.8 (7)
1.2 (11)
1.4 (12)
1.6 (14)
1.8 (16)
500 1000 1500 2000 2500
.4 (4)
3.0 (.79)
2.0 (.53)
1.0 (.26)
0
3000
2 (18)
2.2 (19)
Case Flow
l/min
(USgpm)
5.0 (1.32)
4.0 (1.06)
.2 (2)
.6 (5)
1 (9)
2.4 (21)
2.6 (23)
2.8 (25)
3.0 (27)
3.2 (28)
20 bar (290 psi) diff.
Input Torque
11 bar (160 psi) diff.
Input Torque
11 bar (160 psi) diff.
Case Flow
20 bar (290 psi) diff.
Case Flow
0
Input Torque and Case Flow versus Speed
at 93°C (200°F), Pressure Limit Cut-off and
1.0 bar absolute (0 psi gauge) Inlet
6 (53)
12 (106)
18 (159)
24 (212)
500 1000 1500 2000 2500 3000
3 (27)
9 (80)
15 (133)
21 (186)
27 (239)
Input Torque – Nm (lb.in.)
30 (265)
Speed (r/min)
9 (2.4)
Case
Flow l/min
(USgpm)
6 (1.6)
3 (0.8)
150 bar
(2200 psi)
Input Torque
210 bar (3000 psi)
Input Torque
210 bar (3000 psi) Case Flow
150 bar (2200 psi) Case Flow
26 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
102 (27)
76 (20)
49 (13)
27 (7)
0
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
240 (2125)
210 (1860)
180 (1595)
150 (1325)
120 (1060)
90 (795)
60 (530)
30 (265)
0
50 (67)
40 (54)
0
Input Torque,
Full Stroke
Input Torque and Power at 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
Input torque – Nm (in.lb.)
Efficiency – %
Delivery – l/min (USgpm)Input Power – kW (hp)
250
(3600)
30 (40)
20 (27)
10 (13)
Input Power,
Full Stroke
Input Torque,
Cut-off
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
102 (27)
76 (20)
49 (13)
27 (7)
0
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
240 (2125)
210 (1860)
180 (1595)
150 (1325)
120 (1060)
90 (795)
60 (530)
30 (265)
0
50 (67)
40 (54)
0
Input Torque,
Full Stroke
Input Torque and Power at 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
Input torque – Nm (in.lb.)
Efficiency – %
Delivery – l/min (USgpm)Input Power – kW (hp)
250
(3600)
30 (40)
20 (27)
10 (13)
Input Power,
Full Stroke
Input Torque,
Cut-off
Performance
Industrial
PVM045
72
70
68
66
64
62
60
56
54
52
72
70
68
66
64
62
58
60
56
54
52
50
48
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
Outlet Pressure – bar (psi)
Noise Level – dBA
Noise Level – dBA
Sound pressure data
equivalent to NFPA
Typical Noise Levels at 1800 and 1200 r/min
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
1200 r/min
Min. Flow
1200 r/min
Max. Flow
1800 r/min
Min. Flow
1800 r/min
Max. Flow
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
Outlet Pressure – bar (psi)
Typical Noise Levels at 1500 and 1000 r/min
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
1500 r/min
Max. Flow
1000 r/min
Min. Flow
1500 r/min
Min. Flow
1000 r/min
Max. Flow
58
72
70
68
66
64
62
60
56
54
52
72
70
68
66
64
62
58
60
56
54
52
50
48
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
Outlet Pressure – bar (psi)
Noise Level – dBA
Noise Level – dBA
Sound pressure data
equivalent to NFPA
Typical Noise Levels at 1800 and 1200 r/min
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
1200 r/min
Min. Flow
1200 r/min
Max. Flow
1800 r/min
Min. Flow
1800 r/min
Max. Flow
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
Outlet Pressure – bar (psi)
Typical Noise Levels at 1500 and 1000 r/min
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
1500 r/min
Max. Flow
1000 r/min
Min. Flow
1500 r/min
Min. Flow
1000 r/min
Max. Flow
58
27EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance
Industrial
PVM045
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
76 (20)
57 (15)
38 (10)
19 (5)
0
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
Input Torque and Power at 1200 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
240 (2125)
210 (1860)
180 (1595)
150 (1325)
120 (1060)
90 (795)
60 (530)
30 (265)
0
Input Torque – Nm (in.lb.)
30 (40)
20 (27)
10 (13)
0
Input Power – kW (hp)
Input Torque,
Full Stroke
Input Power,
Full Stroke
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
76 (20)
57 (15)
38 (10)
19 (5)
0
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
Input Torque and Power at 1200 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
240 (2125)
210 (1860)
180 (1595)
150 (1325)
120 (1060)
90 (795)
60 (530)
30 (265)
0
Input Torque – Nm (in.lb.)
30 (40)
20 (27)
10 (13)
0
Input Power – kW (hp)
Input Torque,
Full Stroke
Input Power,
Full Stroke
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
Delivery and Efficiency at 1500 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Input Torque and Power at 1500 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
102 (27)
76 (20)
49 (13)
27 (7)
0
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
240 (2125)
210 (1860)
180 (1595)
150 (1325)
120 (1060)
90 (795)
60 (530)
30 (265)
0
40 (54)
0
Input Torque,
Full Stroke
Input Power,
Full Stroke
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
Input torque – Nm (in.lb.)
Efficiency – %
Delivery – l/min (USgpm)Input Power – kW (hp)
250
(3600)
30 (40)
20 (27)
10 (13)
Delivery and Efficiency at 1500 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Input Torque and Power at 1500 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
102 (27)
76 (20)
49 (13)
27 (7)
0
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
240 (2125)
210 (1860)
180 (1595)
150 (1325)
120 (1060)
90 (795)
60 (530)
30 (265)
0
40 (54)
0
Input Torque,
Full Stroke
Input Power,
Full Stroke
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
Input torque – Nm (in.lb.)
Efficiency – %
Delivery – l/min (USgpm)Input Power – kW (hp)
250
(3600)
30 (40)
20 (27)
10 (13)
28 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance
Industrial
PVM045
2,0 (0.53)
1,8 (0.47)
1,6 (0.42)
1,4 (0.37)
1,2 (0.32)
1,0 (0.26)
0,8 (0.21)
0,6 (0.16)
0,4 (0.10)
0,2 (0.05)
0
Case Flow – l/min (USgpm)
Case Flow Versus Outlet Pressure at 1800 r/min, Full Flow
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
6 (1.59)
5 (1.32)
4 (1.06)
3 (0.79)
2 (0.53)
1 (0.26)
0
Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Case Flow – l/min (USgpm)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
2,0 (0.53)
1,8 (0.47)
1,6 (0.42)
1,4 (0.37)
1,2 (0.32)
1,0 (0.26)
0,8 (0.21)
0,6 (0.16)
0,4 (0.10)
0,2 (0.05)
0
Case Flow – l/min (USgpm)
Case Flow Versus Outlet Pressure at 1800 r/min, Full Flow
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
6 (1.59)
5 (1.32)
4 (1.06)
3 (0.79)
2 (0.53)
1 (0.26)
0
Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Case Flow – l/min (USgpm)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1000 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
76 (20)
57 (15)
38 (10)
19 (5)
0
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
Input Torque and Power at 1000 r/min
50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
240 (2125)
210 (1860)
180 (1595)
150 (1325)
120 (1060)
90 (795)
60 (530)
30 (265)
0
Input Torque – Nm (in.lb.)
30 (40)
20 (27)
10 (13)
0
Input Power – kW (hp)
Input Torque,
Full Stroke
Input Power,
Full Stroke
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1000 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
76 (20)
57 (15)
38 (10)
19 (5)
0
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
Input Torque and Power at 1000 r/min
50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
240 (2125)
210 (1860)
180 (1595)
150 (1325)
120 (1060)
90 (795)
60 (530)
30 (265)
0
Input Torque – Nm (in.lb.)
30 (40)
20 (27)
10 (13)
0
Input Power – kW (hp)
Input Torque,
Full Stroke
Input Power,
Full Stroke
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
29EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Delivery and Case Flow Versus Speed
@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi) gauge Inlet
120 (32)
100 (26)
80 (21)
60 (16)
40 (11)
20 (5)
0
0 500 1000 1500 2000 2500
0,5 (.1)
1,0 (.3)
1,5 (.4)
2,0 (.5)
2,5 (.7)
Speed – r/min
Delivery – l/min (USgpm)
Case Flow – l/min (USgpm)
50 bar (700 psi),
Delivery
280 bar (4000 psi),
Delivery
280 bar (4000 psi),
Case flow
50 bar (700 psi),
Case flow
10 (3)
30 (8)
50 (13)
70 (18)
90 (24)
110 (29)
0
3000
225 (1991)
195 (1726)
165 (1460)
135 (1195)
105 (929)
75 (664)
45 (398)
Input Torque – Nm (in.lb.)
Speed – r/min
0
0 500 1000 1500 2000 2500
25 bar (365 psi)
250 bar (3600 psi)
200 bar (2900 psi)
280 bar (4000 psi)
3000
210 (1858)
180 (1593)
150 (1327)
120 (1062)
90 (796)
60 (531)
30 (265)
17 bar (250 psi)
100 bar (1500 psi)
Input Torque Versus Speed
@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi gauge) inlet
150 bar (2200 psi)
50 bar (700 psi)
Delivery and Case Flow Versus Speed
@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi) gauge Inlet
120 (32)
100 (26)
80 (21)
60 (16)
40 (11)
20 (5)
0
0 500 1000 1500 2000 2500
0,5 (.1)
1,0 (.3)
1,5 (.4)
2,0 (.5)
2,5 (.7)
Speed – r/min
Delivery – l/min (USgpm)
Case Flow – l/min (USgpm)
50 bar (700 psi),
Delivery
280 bar (4000 psi),
Delivery
280 bar (4000 psi),
Case flow
50 bar (700 psi),
Case flow
10 (3)
30 (8)
50 (13)
70 (18)
90 (24)
110 (29)
0
3000
225 (1991)
195 (1726)
165 (1460)
135 (1195)
105 (929)
75 (664)
45 (398)
Input Torque – Nm (in.lb.)
Speed – r/min
0
0 500 1000 1500 2000 2500
25 bar (365 psi)
250 bar (3600 psi)
200 bar (2900 psi)
280 bar (4000 psi)
3000
210 (1858)
180 (1593)
150 (1327)
120 (1062)
90 (796)
60 (531)
30 (265)
17 bar (250 psi)
100 bar (1500 psi)
Input Torque Versus Speed
@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi gauge) inlet
150 bar (2200 psi)
50 bar (700 psi)
Performance
Mobile
PVM045
82
78
74
70
66
62
58
54
50
Noise Level – dBA
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
Outlet Pressure – bar (psi)
600 r/min
Min. Flow
600 r/min
Max. Flow
2600 r/min
Min. Flow
2600 r/min
Max. Flow
Typical Noise Levels
Petroleum Oil (10W) at 93°C (200°F),
1.0 bar absolute (0 psi gauge) Inlet
(Sound pressure data equivalent to NFPA)
0 500 1000 1500 2000 2500 3000
Efficiency – %
Speed – r/min
250 bar
(3600 psi)
200 bar
(2900 psi)
100 bar
(1500 psi)
17 bar
(250 psi)
280 bar
(4000 psi)
150 bar
(2200 psi)
95
90
85
80
75
70
Overall Efficiency Versus Speed
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
50 bar
(700 psi)
82
78
74
70
66
62
58
54
50
Noise Level – dBA
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
Outlet Pressure – bar (psi)
600 r/min
Min. Flow
600 r/min
Max. Flow
2600 r/min
Min. Flow
2600 r/min
Max. Flow
Typical Noise Levels
Petroleum Oil (10W) at 93°C (200°F),
1.0 bar absolute (0 psi gauge) Inlet
(Sound pressure data equivalent to NFPA)
0 500 1000 1500 2000 2500 3000
Efficiency – %
Speed – r/min
250 bar
(3600 psi)
200 bar
(2900 psi)
100 bar
(1500 psi)
17 bar
(250 psi)
280 bar
(4000 psi)
150 bar
(2200 psi)
95
90
85
80
75
70
Overall Efficiency Versus Speed
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
50 bar
(700 psi)
30 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance
Mobile
PVM045
0
500 1000 1500 2000 2500 3000
Input Power @ Full Flow – kW (hp)
Speed – r/min
280 (4000)
250 (3600)
200 (2900)
150 (2200)
100 (1500)
Pressure – bar (psi)
56 (75)
52 (70)
48 (64)
44 (59)
40 (54)
36 (48)
32 (43)
28 (38)
24 (32)
20 (27)
16 (21)
12 (16)
8 (11)
4 (5)
0
Input Power Versus Speed
93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet
6 (1.6)
5 (1.3)
4 (1.1)
3 (0.8)
2 (0.5)
1 (0.3)
0
Case Flow – l/min (USgpm)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
1.Case Flow at 2600 r/min, Full Flow
93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet
42 (11.1)
38 (10.0)
34 (9.0)
30 (7.9)
26 (6.9)
22 (5.8)
18 (4.8)
14 (3.7)
10 (2.6)
Case Flow – l/min (USgpm)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
Case Flow at Cutoff at 2600 r/min
93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet
50 (700)
25 (365)
17 (250)
0
500 1000 1500 2000 2500 3000
Input Power @ Full Flow – kW (hp)
Speed – r/min
280 (4000)
250 (3600)
200 (2900)
150 (2200)
100 (1500)
Pressure – bar (psi)
56 (75)
52 (70)
48 (64)
44 (59)
40 (54)
36 (48)
32 (43)
28 (38)
24 (32)
20 (27)
16 (21)
12 (16)
8 (11)
4 (5)
0
Input Power Versus Speed
93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet
6 (1.6)
5 (1.3)
4 (1.1)
3 (0.8)
2 (0.5)
1 (0.3)
0
Case Flow – l/min (USgpm)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
1.Case Flow at 2600 r/min, Full Flow
93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet
42 (11.1)
38 (10.0)
34 (9.0)
30 (7.9)
26 (6.9)
22 (5.8)
18 (4.8)
14 (3.7)
10 (2.6)
Case Flow – l/min (USgpm)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
Case Flow at Cutoff at 2600 r/min
93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet
50 (700)
25 (365)
17 (250)
31EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Delivery and Efficiency at 1500 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in-lb)
Input Power – kW (hp)
Input Torque and Power at 1800 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
20 (177)
40 (354)
60 (531)
80 (708)
100 (885)
120 (1062)
140 (1239)
160 (1416)
180 (1593)
200 (1770)
220 (1947)
240 (2124)
Input Power,
Full Stroke
Input Torque,
Cut-off
Input Torque,
Full Stroke
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in-lb)
Input Power – kW (hp)
Input Torque and Power at 1500 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
20 (177)
40 (354)
60 (531)
80 (708)
100 (885)
120 (1062)
140 (1239)
160 (1416)
180 (1593)
200 (1770)
220 (1947)
240 (2124)
Input Torque,
Full Stroke
Input Power,
Full Stroke
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Delivery and Efficiency at 1500 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in-lb)
Input Power – kW (hp)
Input Torque and Power at 1800 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
20 (177)
40 (354)
60 (531)
80 (708)
100 (885)
120 (1062)
140 (1239)
160 (1416)
180 (1593)
200 (1770)
220 (1947)
240 (2124)
Input Power,
Full Stroke
Input Torque,
Cut-off
Input Torque,
Full Stroke
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in-lb)
Input Power – kW (hp)
Input Torque and Power at 1500 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
20 (177)
40 (354)
60 (531)
80 (708)
100 (885)
120 (1062)
140 (1239)
160 (1416)
180 (1593)
200 (1770)
220 (1947)
240 (2124)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Performance
Industrial
PVM050
Noise Level – dBA
Typical Noise Levels at 1800 and 1200 r/min with
Petroleum Oil (10W) at 50°C (120°F) and 1.0 bar
absolute (0 psi gauge) Inlet
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
44
48
52
56
60
64
68
72
1800 r/min
min. flow
1200 r/min
min. flow
Noise Level – dBA
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
Sound pressure data
equivalent to NFPA.
44
48
52
56
60
64
68
72
1500 r/min
min. flow
1000 r/min
min. flow
1000 r/min
max. flow
1500 r/min
max. flow
1200 r/min
max. flow
1800 r/min
max. flow
Typical Noise Levels at 1500 and 1000 r/min with
Petroleum Oil (10W) at 50°C (120°F) and 1.0 bar
absolute (0 psi gauge) Inlet
Noise Level – dBA
Typical Noise Levels at 1800 and 1200 r/min with
Petroleum Oil (10W) at 50°C (120°F) and 1.0 bar
absolute (0 psi gauge) Inlet
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
44
48
52
56
60
64
68
72
1800 r/min
min. flow
1200 r/min
min. flow
Noise Level – dBA
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
Sound pressure data
equivalent to NFPA.
44
48
52
56
60
64
68
72
1500 r/min
min. flow
1000 r/min
min. flow
1000 r/min
max. flow
1500 r/min
max. flow
1200 r/min
max. flow
1800 r/min
max. flow
Typical Noise Levels at 1500 and 1000 r/min with
Petroleum Oil (10W) at 50°C (120°F) and 1.0 bar
absolute (0 psi gauge) Inlet
32 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance
Industrial
PVM050
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Delivery and Efficiency at 1500 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in-lb)
Input Power – kW (hp)
Input Torque and Power at 1800 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
20 (177)
40 (354)
60 (531)
80 (708)
100 (885)
120 (1062)
140 (1239)
160 (1416)
180 (1593)
200 (1770)
220 (1947)
240 (2124)
Input Power,
Full Stroke
Input Torque,
Cut-off
Input Torque,
Full Stroke
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in-lb)
Input Power – kW (hp)
Input Torque and Power at 1500 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
20 (177)
40 (354)
60 (531)
80 (708)
100 (885)
120 (1062)
140 (1239)
160 (1416)
180 (1593)
200 (1770)
220 (1947)
240 (2124)
Input Torque,
Full Stroke
Input Power,
Full Stroke
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Delivery and Efficiency at 1500 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in-lb)
Input Power – kW (hp)
Input Torque and Power at 1800 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
20 (177)
40 (354)
60 (531)
80 (708)
100 (885)
120 (1062)
140 (1239)
160 (1416)
180 (1593)
200 (1770)
220 (1947)
240 (2124)
Input Power,
Full Stroke
Input Torque,
Cut-off
Input Torque,
Full Stroke
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in-lb)
Input Power – kW (hp)
Input Torque and Power at 1500 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
20 (177)
40 (354)
60 (531)
80 (708)
100 (885)
120 (1062)
140 (1239)
160 (1416)
180 (1593)
200 (1770)
220 (1947)
240 (2124)
Input Torque,
Full Stroke
Input Power,
Full Stroke
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Delivery and Efficiency at 1000 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Delivery – l/min (USgpm)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1200 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
20 (177)
40 (354)
60 (531)
80 (708)
100 (885)
120 (1062)
140 (1239)
160 (1416)
180 (1593)
200 (1770)
220 (1947)
240 (2124)
Input Power,
Full Stroke
Input Torque,
Full Stroke
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1000 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
20 (177)
40 (354)
60 (531)
80 (708)
100 (885)
120 (1062)
140 (1239)
160 (1416)
180 (1593)
200 (1770)
220 (1947)
240 (2124)
Input Torque,
Full Stroke
Input Power,
Full Stroke
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Delivery and Efficiency at 1000 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Delivery – l/min (USgpm)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1200 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
20 (177)
40 (354)
60 (531)
80 (708)
100 (885)
120 (1062)
140 (1239)
160 (1416)
180 (1593)
200 (1770)
220 (1947)
240 (2124)
Input Power,
Full Stroke
Input Torque,
Full Stroke
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1000 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
20 (177)
40 (354)
60 (531)
80 (708)
100 (885)
120 (1062)
140 (1239)
160 (1416)
180 (1593)
200 (1770)
220 (1947)
240 (2124)
Input Torque,
Full Stroke
Input Power,
Full Stroke
33EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Case Flow l/min – (USgpm)
Outlet Pressure – bar (psi)
Case Flow versus Outlet Pressure at 1800 r/min, Full Flow,
50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
0.1 (0.03)
0.2 (0.05)
0.3 (0.08)
0.4 (0.11)
0.5 (0.13)
0.6 (0.16)
0.7 (0.18)
0.8 (0.21)
0.9 (0.24)
1.0 (0.26)
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Case Flow l/min – (USgpm)
Outlet Pressure – bar (psi)
0
1 (0.26)
2 (0.53)
3 (0.79)
4 (1.06)
5 (1.32)
6 (1.59)
7 (1.85)
8 (2.11)
9 (2.38)
10 (2.64)
Case Flow versus Outlet Pressure at Cutoff, 1800 r/min,
50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Case Flow l/min – (USgpm)
Outlet Pressure – bar (psi)
Case Flow versus Outlet Pressure at 1800 r/min, Full Flow,
50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
0.1 (0.03)
0.2 (0.05)
0.3 (0.08)
0.4 (0.11)
0.5 (0.13)
0.6 (0.16)
0.7 (0.18)
0.8 (0.21)
0.9 (0.24)
1.0 (0.26)
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Case Flow l/min – (USgpm)
Outlet Pressure – bar (psi)
0
1 (0.26)
2 (0.53)
3 (0.79)
4 (1.06)
5 (1.32)
6 (1.59)
7 (1.85)
8 (2.11)
9 (2.38)
10 (2.64)
Case Flow versus Outlet Pressure at Cutoff, 1800 r/min,
50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
Performance
Industrial
PVM050
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Delivery and Efficiency at 1000 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Delivery – l/min (USgpm)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1200 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
20 (177)
40 (354)
60 (531)
80 (708)
100 (885)
120 (1062)
140 (1239)
160 (1416)
180 (1593)
200 (1770)
220 (1947)
240 (2124)
Input Power,
Full Stroke
Input Torque,
Full Stroke
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1000 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
20 (177)
40 (354)
60 (531)
80 (708)
100 (885)
120 (1062)
140 (1239)
160 (1416)
180 (1593)
200 (1770)
220 (1947)
240 (2124)
Input Torque,
Full Stroke
Input Power,
Full Stroke
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Delivery and Efficiency at 1000 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Delivery – l/min (USgpm)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1200 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
20 (177)
40 (354)
60 (531)
80 (708)
100 (885)
120 (1062)
140 (1239)
160 (1416)
180 (1593)
200 (1770)
220 (1947)
240 (2124)
Input Power,
Full Stroke
Input Torque,
Full Stroke
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1000 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
20 (177)
40 (354)
60 (531)
80 (708)
100 (885)
120 (1062)
140 (1239)
160 (1416)
180 (1593)
200 (1770)
220 (1947)
240 (2124)
Input Torque,
Full Stroke
Input Power,
Full Stroke
34 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance
Mobile
PVM050
Sound pressure data
equivalent to NFPA.
Noise Level – dBA
Typical Noise Levels at 2600 & 600 r/min
with Petroleum Oil (10W) at 93°C (200°F) and
1.0 bar absolute (0 psi gauge) inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
64
68
74
78
82
86
66
72
76
80
84
70
88
2600 r/min
max. flow
600 r/min
max. flow
600 r/min
min. flow
Outlet Pressure – bar (psi)
Overall Efficiency (%)
Overall Efficiency versus Speed
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet
0
500 1000 1500 2000 2500
Speed (r/min)
50
60
75
85
95
55
70
80
90
65
100
3000
100 bar (1500 psi)
200 bar
(2900 psi)
230 bar (3300 psi)
210 bar (3000 psi)
Delivery and Case Flow versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) inlet
0
Speed (r/min)
Delivery – l/min (USgpm)
40 (11)
60 (16)
80 (21)
100 (26)
120 (32)
500 1000 1500 2000 2500
30 (8)
50 (13)
70 (18)
90 (24)
110 (29)
130 (34)
140 (37)
20 (5)
10 (3)
Case Flow – l/min (USgpm)
4 (1.06)
3 (0.79)
5 (1.32)
2 (0.53)
1 (0.26)
0
3000
210 bar (3000
psi) Case Flow
50 bar (725 psi)
Case Flow
210 bar (3000
psi) Delivery
50 bar (725
psi) Delivery
2600 r/min
min. flow
Sound pressure data
equivalent to NFPA.
Noise Level – dBA
Typical Noise Levels at 2600 & 600 r/min with Petroleum Oil (10W)
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
64
68
74
78
82
86
66
72
76
80
84
70
88
2600 r/min
max. flow
600 r/min
max. flow
600 r/min
min. flow
Outlet Pressure – bar (psi)
Overall Efficiency (%)
Overall Efficiency versus Speed
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet
0
500 1000 1500 2000 2500
Speed (r/min)
50
60
75
85
95
55
70
80
90
65
100
3000
100 bar (1500 psi)
200 bar
(2900 psi)
230 bar (3300 psi)
210 bar (3000 psi)
Delivery and Case Flow versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) inlet
0
Speed (r/min)
Delivery – l/min (USgpm)
40 (11)
60 (16)
80 (21)
100 (26)
120 (32)
500 1000 1500 2000 2500
30 (8)
50 (13)
70 (18)
90 (24)
110 (29)
130 (34)
140 (37)
20 (5)
10 (3)
Case Flow – l/min (USgpm)
4 (1.06)
3 (0.79)
5 (1.32)
2 (0.53)
1 (0.26)
0
3000
210 bar (3000
psi) Case Flow
50 bar (725 psi)
Case Flow
210 bar (3000
psi) Delivery
50 bar (725
psi) Delivery
2600 r/min
min. flow
Sound pressure data
equivalent to NFPA.
Noise Level – dBA
Typical Noise Levels at 2600 & 600 r/min with Petroleum Oil (10W)
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
64
68
74
78
82
86
66
72
76
80
84
70
88
2600 r/min
max. flow
600 r/min
max. flow
600 r/min
min. flow
Outlet Pressure – bar (psi)
Overall Efficiency (%)
Overall Efficiency versus Speed
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet
0
500 1000 1500 2000 2500
Speed (r/min)
50
60
75
85
95
55
70
80
90
65
100
3000
100 bar (1500 psi)
200 bar
(2900 psi)
230 bar (3300 psi)
210 bar (3000 psi)
Delivery and Case Flow versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) inlet
0
Speed (r/min)
Delivery – l/min (USgpm)
40 (11)
60 (16)
80 (21)
100 (26)
120 (32)
500 1000 1500 2000 2500
30 (8)
50 (13)
70 (18)
90 (24)
110 (29)
130 (34)
140 (37)
20 (5)
10 (3)
Case Flow – l/min (USgpm)
4 (1.06)
3 (0.79)
5 (1.32)
2 (0.53)
1 (0.26)
0
3000
210 bar (3000
psi) Case Flow
50 bar (725 psi)
Case Flow
210 bar (3000
psi) Delivery
50 bar (725
psi) Delivery
2600 r/min
min. flow
35EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance
Mobile
PVM050
0
1000500 20001500
Speed (r/min)
2500
Input Torque – Nm (in.lb.)
Input Torque versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (221)
50 (442)
75 (664)
100 (885)
125 (1106)
150 (1327)
175 (1549)
200 (1770)
250 (2212)
275 (2434)
300 (2655)
3000
210 bar
(3000 psi)
200 bar (2900 psi)
225 (1991)
17 bar (250 psi)
100 bar (1500 psi)
230 bar
(3300 psi)
0 1000500 20001500
Speed (r/min)
2500
Input Power – kW (hp)
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
30 (40)
35 (47)
40 (54)
45 (60)
50 (67)
55 (74)
60 (80)
Input Power versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
230 bar (3300 psi)
210 bar (3000 psi)
200 bar (2900 psi)
100 bar (1500 psi)
17 bar (250 psi)
Input Torque and Case Flow versus Speed at
93°C (200°F), Load Sense Standby and 1.0 bar
absolute (0 psi gauge) Inlet
0
Speed (r/min)
Input Torque – Nm (in.lb.)
2 (18)
3 (27)
4 (35)
5 (44)
6 (53)
500 1000 1500 2000 2500
1 (9)
3.0 (.79)
2.0 (.53)
1.0 (.26)
0
3000
7 (62)
8 (71)
20 bar (300 psi) diff.
Input Torque
20 bar (300 psi)
diff. Case Flow
11 bar (160 psi)
diff.Case Flow
11 bar (160 psi) diff.
Input Torque
Case Flow
l/min
(USgpm)
5.0 (1.32)
4.0 (1.06)
0
Input Torque and Case Flow versus Speed
at 93°C (200°F), Pressure Limit Cut-off and
1.0 bar absolute (0 psi gauge) Inlet
10 (88)
20 (177)
30 (265)
40 (354)
500 1000 1500 2000 2500 3000
5 (44)
15 (133)
25 (221)
35 (310)
45 (398)
Input Torque – Nm (in.lb.)
50 (442)
55 (487)
210 bar (3000 psi) Input Torque
Speed (r/min)
12 (3.2)
9 (2.4)
210 bar
(3000 psi)
Case Flow
150 bar (2200 psi) Case Flow
Case
Flow l/min
(USgpm)
6 (1.6)
3 (0.8)
150 bar (2200 psi)
Input Torque
0
1000500 20001500
Speed (r/min)
2500
Input Torque – Nm (in.lb.)
Input Torque versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (221)
50 (442)
75 (664)
100 (885)
125 (1106)
150 (1327)
175 (1549)
200 (1770)
250 (2212)
275 (2434)
300 (2655)
3000
210 bar
(3000 psi)
200 bar (2900 psi)
225 (1991)
17 bar (250 psi)
100 bar (1500 psi)
230 bar
(3300 psi)
0 1000500 20001500
Speed (r/min)
2500
Input Power – kW (hp)
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
30 (40)
35 (47)
40 (54)
45 (60)
50 (67)
55 (74)
60 (80)
Input Power versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
230 bar (3300 psi)
210 bar (3000 psi)
200 bar (2900 psi)
100 bar (1500 psi)
17 bar (250 psi)
Input Torque and Case Flow versus Speed at
93°C (200°F), Load Sense Standby and 1.0 bar
absolute (0 psi gauge) Inlet
0
Speed (r/min)
Input Torque – Nm (in.lb.)
2 (18)
3 (27)
4 (35)
5 (44)
6 (53)
500 1000 1500 2000 2500
1 (9)
3.0 (.79)
2.0 (.53)
1.0 (.26)
0
3000
7 (62)
8 (71)
20 bar (300 psi) diff.
Input Torque
20 bar (300 psi)
diff. Case Flow
11 bar (160 psi)
diff.Case Flow
11 bar (160 psi) diff.
Input Torque
Case Flow
l/min
(USgpm)
5.0 (1.32)
4.0 (1.06)
0
Input Torque and Case Flow versus Speed
at 93°C (200°F), Pressure Limit Cut-off and
1.0 bar absolute (0 psi gauge) Inlet
10 (88)
20 (177)
30 (265)
40 (354)
500 1000 1500 2000 2500 3000
5 (44)
15 (133)
25 (221)
35 (310)
45 (398)
Input Torque – Nm (in.lb.)
50 (442)
55 (487)
210 bar (3000 psi) Input Torque
Speed (r/min)
12 (3.2)
9 (2.4)
210 bar
(3000 psi)
Case Flow
150 bar (2200 psi) Case Flow
Case
Flow l/min
(USgpm)
6 (1.6)
3 (0.8)
150 bar (2200 psi)
Input Torque
0
1000500 20001500
Speed (r/min)
2500
Input Torque – Nm (in.lb.)
Input Torque versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (221)
50 (442)
75 (664)
100 (885)
125 (1106)
150 (1327)
175 (1549)
200 (1770)
250 (2212)
275 (2434)
300 (2655)
3000
210 bar
(3000 psi)
200 bar (2900 psi)
225 (1991)
17 bar (250 psi)
100 bar (1500 psi)
230 bar
(3300 psi)
0 1000500 20001500
Speed (r/min)
2500
Input Power – kW (hp)
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
30 (40)
35 (47)
40 (54)
45 (60)
50 (67)
55 (74)
60 (80)
Input Power versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
230 bar (3300 psi)
210 bar (3000 psi)
200 bar (2900 psi)
100 bar (1500 psi)
17 bar (250 psi)
Input Torque and Case Flow versus Speed at
93°C (200°F), Load Sense Standby and 1.0 bar
absolute (0 psi gauge) Inlet
0
Speed (r/min)
Input Torque – Nm (in.lb.)
2 (18)
3 (27)
4 (35)
5 (44)
6 (53)
500 1000 1500 2000 2500
1 (9)
3.0 (.79)
2.0 (.53)
1.0 (.26)
0
3000
7 (62)
8 (71)
20 bar (300 psi) diff.
Input Torque
20 bar (300 psi)
diff. Case Flow
11 bar (160 psi)
diff.Case Flow
11 bar (160 psi) diff.
Input Torque
Case Flow
l/min
(USgpm)
5.0 (1.32)
4.0 (1.06)
0
Input Torque and Case Flow versus Speed
at 93°C (200°F), Pressure Limit Cut-off and
1.0 bar absolute (0 psi gauge) Inlet
10 (88)
20 (177)
30 (265)
40 (354)
500 1000 1500 2000 2500 3000
5 (44)
15 (133)
25 (221)
35 (310)
45 (398)
Input Torque – Nm (in.lb.)
50 (442)
55 (487)
210 bar (3000 psi) Input Torque
Speed (r/min)
12 (3.2)
9 (2.4)
210 bar
(3000 psi)
Case Flow
150 bar (2200 psi) Case Flow
Case
Flow l/min
(USgpm)
6 (1.6)
3 (0.8)
150 bar (2200 psi)
Input Torque
0
1000500 20001500
Speed (r/min)
2500
Input Torque – Nm (in.lb.)
Input Torque versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (221)
50 (442)
75 (664)
100 (885)
125 (1106)
150 (1327)
175 (1549)
200 (1770)
250 (2212)
275 (2434)
300 (2655)
3000
210 bar
(3000 psi)
200 bar (2900 psi)
225 (1991)
17 bar (250 psi)
100 bar (1500 psi)
230 bar
(3300 psi)
0 1000500 20001500
Speed (r/min)
2500
Input Power – kW (hp)
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
30 (40)
35 (47)
40 (54)
45 (60)
50 (67)
55 (74)
60 (80)
Input Power versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
230 bar (3300 psi)
210 bar (3000 psi)
200 bar (2900 psi)
100 bar (1500 psi)
17 bar (250 psi)
Input Torque and Case Flow versus Speed at
93°C (200°F), Load Sense Standby and 1.0 bar
absolute (0 psi gauge) Inlet
0
Speed (r/min)
Input Torque – Nm (in.lb.)
2 (18)
3 (27)
4 (35)
5 (44)
6 (53)
500 1000 1500 2000 2500
1 (9)
3.0 (.79)
2.0 (.53)
1.0 (.26)
0
3000
7 (62)
8 (71)
20 bar (300 psi) diff.
Input Torque
20 bar (300 psi)
diff. Case Flow
11 bar (160 psi)
diff.Case Flow
11 bar (160 psi) diff.
Input Torque
Case Flow
l/min
(USgpm)
5.0 (1.32)
4.0 (1.06)
0
Input Torque and Case Flow versus Speed
at 93°C (200°F), Pressure Limit Cut-off and
1.0 bar absolute (0 psi gauge) Inlet
10 (88)
20 (177)
30 (265)
40 (354)
500 1000 1500 2000 2500 3000
5 (44)
15 (133)
25 (221)
35 (310)
45 (398)
Input Torque – Nm (in.lb.)
50 (442)
55 (487)
210 bar (3000 psi) Input Torque
Speed (r/min)
12 (3.2)
9 (2.4)
210 bar
(3000 psi)
Case Flow
150 bar (2200 psi) Case Flow
Case
Flow l/min
(USgpm)
6 (1.6)
3 (0.8)
150 bar (2200 psi)
Input Torque
36 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
60 (80)
50 (67)
40 (54)
30 (40)
20 (27)
10 (13)
0
Input Power – kW (hp)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Input Torque,
Cut-off
Input Torque and Power at 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
Delivery and Efficiency at 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Input Torque – Nm (in.lb.)
Outlet Pressure – bar (psi)
130 (34)
104 (28)
78 (21)
52 (14)
26 (7)
0
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
300 (2655)
270 (2390)
240 (2124)
210 (1859)
180 (1593)
150 (1328)
120 (1062)
90 (797)
60 (531)
30 (266)
0
60 (80)
50 (67)
40 (54)
30 (40)
20 (27)
10 (13)
0
Input Power – kW (hp)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Input Torque,
Cut-off
Input Torque and Power at 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
Delivery and Efficiency at 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Input Torque – Nm (in.lb.)
Outlet Pressure – bar (psi)
130 (34)
104 (28)
78 (21)
52 (14)
26 (7)
0
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
300 (2655)
270 (2390)
240 (2124)
210 (1859)
180 (1593)
150 (1328)
120 (1062)
90 (797)
60 (531)
30 (266)
0
Performance
Industrial
PVM057
70
66
62
58
54
74
70
66
62
58
54
Noise Level – dBA
Typical Noise Levels at 1800 and 1200 r/min
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
Outlet Pressure – bar (psi)
(Sound pressure data
equivalent to NFPA)
1200 r/min
Min. Flow
1200 r/min
Max. Flow
1800 r/min
Min. Flow
1800 r/min
Max. Flow
Typical Noise Levels at 1500 and 1000 r/min
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
(1500) (2200) (2900) (3600)
Noise Level – dBA
050
(700)
100 150 200 250 300
(4400)
Outlet Pressure – bar (psi)
1000 r/min
Min. Flow
1000 r/min
Max. Flow
1500 r/min
Min. Flow
1500 r/min
Max. Flow
70
66
62
58
54
74
70
66
62
58
54
Noise Level – dBA
Typical Noise Levels at 1800 and 1200 r/min
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
Outlet Pressure – bar (psi)
(Sound pressure data
equivalent to NFPA)
1200 r/min
Min. Flow
1200 r/min
Max. Flow
1800 r/min
Min. Flow
1800 r/min
Max. Flow
Typical Noise Levels at 1500 and 1000 r/min
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
(1500) (2200) (2900) (3600)
Noise Level – dBA
050
(700)
100 150 200 250 300
(4400)
Outlet Pressure – bar (psi)
1000 r/min
Min. Flow
1000 r/min
Max. Flow
1500 r/min
Min. Flow
1500 r/min
Max. Flow
37EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100 (26)
80 (21)
60 (16)
40 (11)
20 (5)
0
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Input Torque and Power at 1200 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
40 (54)
30 (40)
20 (27)
10 (13)
0
330 (2921)
300 (2655)
270 (2390)
240 (2124)
210 (1859)
180 (1593)
150 (1328)
120 (1062)
90 (797)
60 (531)
30 (266)
0
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100 (26)
80 (21)
60 (16)
40 (11)
20 (5)
0
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Input Torque and Power at 1200 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
40 (54)
30 (40)
20 (27)
10 (13)
0
330 (2921)
300 (2655)
270 (2390)
240 (2124)
210 (1859)
180 (1593)
150 (1328)
120 (1062)
90 (797)
60 (531)
30 (266)
0
Performance
Industrial
PVM057
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Input Torque and Power at 1500 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
330 (2921)
300 (2655)
270 (2390)
240 (2124)
210 (1859)
180 (1593)
150 (1328)
120 (1062)
90 (797)
60 (531)
30 (266)
0
60 (80)
50 (67)
40 (54)
30 (40)
20 (27)
10 (13)
0
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1500 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100 (26)
80 (21)
60 (16)
40 (11)
20 (5)
0
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Input Torque and Power at 1500 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
330 (2921)
300 (2655)
270 (2390)
240 (2124)
210 (1859)
180 (1593)
150 (1328)
120 (1062)
90 (797)
60 (531)
30 (266)
0
60 (80)
50 (67)
40 (54)
30 (40)
20 (27)
10 (13)
0
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1500 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100 (26)
80 (21)
60 (16)
40 (11)
20 (5)
0
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
38 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
5 (1.32)
4 (1.06)
3 (0.79)
2 (0.53)
1 (0.26)
0
Case Flow Versus Outlet Pressure at Full Flow, 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Case Flow – l/min (USgpm)
1,1 (0.29)
1,0 (0.26)
0,9 (0.24)
0,8 (0.21)
0,7 (0.18)
0,6 (0.16)
0,5 (0.13)
Case Flow – l/min (USgpm)
Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
5 (1.32)
4 (1.06)
3 (0.79)
2 (0.53)
1 (0.26)
0
Case Flow Versus Outlet Pressure at Full Flow, 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Case Flow – l/min (USgpm)
1,1 (0.29)
1,0 (0.26)
0,9 (0.24)
0,8 (0.21)
0,7 (0.18)
0,6 (0.16)
0,5 (0.13)
Case Flow – l/min (USgpm)
Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
Performance
Industrial
PVM057
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1000 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
80 (21)
60 (16)
40 (11)
20 (5)
0
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Input Torque and Power at 1000 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
330 (2921)
300 (2655)
270 (2390)
240 (2124)
210 (1859)
180 (1593)
150 (1328)
120 (1062)
90 (797)
60 (531)
30 (266)
0
40 (54)
30 (40)
20 (27)
10 (13)
0
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1000 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
80 (21)
60 (16)
40 (11)
20 (5)
0
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Input Torque and Power at 1000 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
330 (2921)
300 (2655)
270 (2390)
240 (2124)
210 (1859)
180 (1593)
150 (1328)
120 (1062)
90 (797)
60 (531)
30 (266)
0
40 (54)
30 (40)
20 (27)
10 (13)
0
39EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance
Mobile
PVM057
82
78
74
70
66
62
58
54
50
Noise Level – dBA
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
Outlet Pressure – bar (psi)
600 r/min
Min. Flow
600 r/min
Max. Flow
2500 r/min
Min. Flow
2500 r/min
Max. Flow
Typical Noise Levels
Petroleum Oil (10W) at 93°C (200°F),
1.0 bar absolute (0 psi gauge) Inlet
(Sound pressure
data equivalent to NFPA)
0
500 1000 1500 2000
2500
Efficiency – %
Speed – r/min
250 bar
(3600 psi)
200 bar
(2900psi)
50 bar
(700 psi)
280 bar
(4000 psi)
150 bar
(2200 psi)
95
90
85
80
75
70
65
100 bar
(1500 psi)
Overall Efficiency Versus Speed
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
82
78
74
70
66
62
58
54
50
Noise Level – dBA
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
Outlet Pressure – bar (psi)
600 r/min
Min. Flow
600 r/min
Max. Flow
2500 r/min
Min. Flow
2500 r/min
Max. Flow
Typical Noise Levels
Petroleum Oil (10W) at 93°C (200°F),
1.0 bar absolute (0 psi gauge) Inlet
(Sound pressure
data equivalent to NFPA)
0
500 1000 1500 2000
2500
Efficiency – %
Speed – r/min
250 bar
(3600 psi)
200 bar
(2900psi)
50 bar
(700 psi)
280 bar
(4000 psi)
150 bar
(2200 psi)
95
90
85
80
75
70
65
100 bar
(1500 psi)
Overall Efficiency Versus Speed
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
280 (2478)
240 (2124)
200 (1770)
160 (1416)
80 (708)
40 (354)
Input Torque – Nm (in.lb.)
Speed – r/min
0
0 500 1000 1500 2000 2500 3000
300 (2655)
260 (1858)
220 (1947)
180 (1593)
120 (1062)
100 (885)
60 (531)
20 (177)
140 (1239)
320 (2832)
Input Torque Versus Speed
@ 93°C (200°F), full flow and
1.0 bar absolute (0 psi gauge) inlet
120 (32)
100 (26)
80 (21)
60 (16)
40 (11)
20 (5)
0
0 500 1000 1500 2000 2500
1,0 (0.3)
2,0 (0.5)
3,0 (0.8)
Speed – r/min
Case Flow – l/min (USgpm)
50 bar (700 psi),
Delivery
280 bar (4000 psi),
Delivery
280 bar (4000 psi),
Case flow
10 (3)
30 (8)
50 (13)
70 (18)
90 (24)
110 (29)
0
140 (37)
130 (34)
150 (40)
4,0 (1.1)
5,0 (1.3)
6,0 (1.6)
50 bar (700 psi),
Case flow
Delivery and Case Flow Versus Speed
@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi) gauge Inlet
100 bar
(1500 psi)
250 bar
(3600 psi)
150 bar
(2200 psi)
17 bar
(250 psi)
200 bar
(2900 psi)
320 bar
(4600 psi)
280 bar
(4000 psi)
50 bar
(700 psi)
280 (2478)
240 (2124)
200 (1770)
160 (1416)
80 (708)
40 (354)
Input Torque – Nm (in.lb.)
Speed – r/min
0
0 500 1000 1500 2000 2500 3000
300 (2655)
260 (1858)
220 (1947)
180 (1593)
120 (1062)
100 (885)
60 (531)
20 (177)
140 (1239)
320 (2832)
Input Torque Versus Speed
@ 93°C (200°F), full flow and
1.0 bar absolute (0 psi gauge) inlet
120 (32)
100 (26)
80 (21)
60 (16)
40 (11)
20 (5)
0
0 500 1000 1500 2000 2500
1,0 (0.3)
2,0 (0.5)
3,0 (0.8)
Speed – r/min
Case Flow – l/min (USgpm)
50 bar (700 psi),
Delivery
280 bar (4000 psi),
Delivery
280 bar (4000 psi),
Case flow
10 (3)
30 (8)
50 (13)
70 (18)
90 (24)
110 (29)
0
140 (37)
130 (34)
150 (40)
4,0 (1.1)
5,0 (1.3)
6,0 (1.6)
50 bar (700 psi),
Case flow
Delivery and Case Flow Versus Speed
@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi) gauge Inlet
100 bar
(1500 psi)
250 bar
(3600 psi)
150 bar
(2200 psi)
17 bar
(250 psi)
200 bar
(2900 psi)
320 bar
(4600 psi)
280 bar
(4000 psi)
50 bar
(700 psi)
40 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance
Mobile
PVM057
0 500 1000 1500 2000 2500
Input Power @ Full Flow – kW (hp)
Speed – r/min
250 (3600)
200 (2900)
150 (2200)
100 (1500)
50 (700)
17 (250)
280 (4000)
320 (4600)
Pressure – bar (psi)
60 (80)
48 (64)
36 (48)
24 (32)
12 (16)
66 (89)
72 (97)
78 (105)
6 (8)
18 (24)
30 (40)
42 (56)
54 (72)
0
Input Power Versus Speed
93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet
20 bar (300 psi)
differential,
Input Torque
11 bar (160 psi)
differential,
Input Torque
20 bar (300 psi) differential, Case Flow
0
0 500 1000 1500 2000 2500
Speed – r/min
Input Torque – Nm (in.lb.)
Case Flow – l/min (USgpm)
8.0 (2.11)
6.0 (1.58)
2.0 (0.53)
4.0 (1.06)
6 (53)
4 (35)
2 (18)
0
1 (9)
3 (27)
5 (44)
Input Torque and Case Flow Versus Speed
@ 93°C (200°F), load sense standby
and 1.0 bar absolute (0 psi gauge) inlet
100 (885)
80 (708)
60 (531)
40 (354)
20 (177)
0 500 1000 1500 2000 2500
2 (0.5)
4 (1.1)
6 (1.6)
8 (2.1)
10 (2.6)
Case Flow – l/min (USgpm)
Input Torque – Nm (in.lb.)
Speed – r/min
280 bar (4000 psi)
Input Torque
150 bar (2200 psi), Input Torque
280 bar
(4000 psi)
Case Flow
150 bar (2200 psi), Case Flow
10 (88)
30 (265)
50 (442)
70 (619)
90 (796)
Input Torque and Case Flow Versus Speed
@ 93°C (200°F), cut-off and 1.0 bar absolute (0 psi gauge) inlet
11 bar (160 psi) differential,
Case Flow
41EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
0
20 (5)
40 (11)
60 (16)
80 (21)
100 (26)
0
10
20
30
40
50
60
70
80
90
100
120 (32)
Volumetric Efficiency
Delivery (effective flow)
Overall Efficiency
Delivery and Efficiency at 1500 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
0
0
10
20
30
40
50
60
70
80
90
100
20 (5)
40 (11)
60 (16)
80 (21)
100 (26)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1800 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
30 (226)
60 (531)
90 (1327)
120 (1062)
150 (1328)
180 (1593)
210 (1859)
Input Torque,
Cut-off
Input To rque,
Full Stroke
Input Power,
Full Stroke
240 (2124)
270 (2390)
Outlet Pressure – bar (psi)
Input Torque and Power at 1500 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
0
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
30 (226)
60 (531)
90 (1327)
120 (1062)
150 (1328)
180 (1593)
210 (1859)
240 (2124)
270 (2390)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Delivery (effective flow)
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
0
20 (5)
40 (11)
60 (16)
80 (21)
100 (26)
0
10
20
30
40
50
60
70
80
90
100
120 (32)
Volumetric Efficiency
Delivery (effective flow)
Overall Efficiency
Delivery and Efficiency at 1500 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
0
0
10
20
30
40
50
60
70
80
90
100
20 (5)
40 (11)
60 (16)
80 (21)
100 (26)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1800 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
30 (226)
60 (531)
90 (1327)
120 (1062)
150 (1328)
180 (1593)
210 (1859)
Input Torque,
Cut-off
Input To rque,
Full Stroke
Input Power,
Full Stroke
240 (2124)
270 (2390)
Outlet Pressure – bar (psi)
Input Torque and Power at 1500 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
0
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
30 (226)
60 (531)
90 (1327)
120 (1062)
150 (1328)
180 (1593)
210 (1859)
240 (2124)
270 (2390)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Delivery (effective flow)
Performance
Industrial
PVM063
Noise Level – dBA
Typical Noise Levels at 1800 and 1200 r/min. with
Petroleum Oil (10W) at 50°C (120°F) and 1.0 bar
absolute (0 psi gauge) Inlet
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
50
55
60
65
70
75
1200 r/min
max. flow
1800 r/min
min. flow
1200 r/min
min. flow
1800 r/min
max. flow
Sound pressure data
equivalent to NFPA.
Noise Level – dBA
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
50
55
65
70
75
1500 r/min
max. flow
1000 r/min
min. flow
Typical Noise Levels at 1500 and 1000 r/min. with
Petroleum Oil (10W) at 50°C (120°F) and 1.0 bar
absolute (0 psi gauge) Inlet
60
1000 r/min
max. flow
1500 r/min
min. flow
Noise Level – dBA
Typical Noise Levels at 1800 and 1200 r/min. with
Petroleum Oil (10W) at 50°C (120°F) and 1.0 bar
absolute (0 psi gauge) Inlet
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
50
55
60
65
70
75
1200 r/min
max. flow
1800 r/min
min. flow
1200 r/min
min. flow
1800 r/min
max. flow
Sound pressure data
equivalent to NFPA.
Noise Level – dBA
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
50
55
65
70
75
1500 r/min
max. flow
1000 r/min
min. flow
Typical Noise Levels at 1500 and 1000 r/min. with
Petroleum Oil (10W) at 50°C (120°F) and 1.0 bar
absolute (0 psi gauge) Inlet
60
1000 r/min
max. flow
1500 r/min
min. flow
42 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance
Industrial
PVM063
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
0
20 (5)
40 (11)
60 (16)
80 (21)
100 (26)
0
10
20
30
40
50
60
70
80
90
100
120 (32)
Volumetric Efficiency
Delivery (effective flow)
Overall Efficiency
Delivery and Efficiency at 1500 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
0
0
10
20
30
40
50
60
70
80
90
100
20 (5)
40 (11)
60 (16)
80 (21)
100 (26)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1800 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
30 (226)
60 (531)
90 (1327)
120 (1062)
150 (1328)
180 (1593)
210 (1859)
Input Torque,
Cut-off
Input To rque,
Full Stroke
Input Power,
Full Stroke
240 (2124)
270 (2390)
Outlet Pressure – bar (psi)
Input Torque and Power at 1500 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
0
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
30 (226)
60 (531)
90 (1327)
120 (1062)
150 (1328)
180 (1593)
210 (1859)
240 (2124)
270 (2390)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Delivery (effective flow)
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
0
20 (5)
40 (11)
60 (16)
80 (21)
100 (26)
0
10
20
30
40
50
60
70
80
90
100
120 (32)
Volumetric Efficiency
Delivery (effective flow)
Overall Efficiency
Delivery and Efficiency at 1500 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
0
0
10
20
30
40
50
60
70
80
90
100
20 (5)
40 (11)
60 (16)
80 (21)
100 (26)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1800 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
30 (226)
60 (531)
90 (1327)
120 (1062)
150 (1328)
180 (1593)
210 (1859)
Input Torque,
Cut-off
Input To rque,
Full Stroke
Input Power,
Full Stroke
240 (2124)
270 (2390)
Outlet Pressure – bar (psi)
Input Torque and Power at 1500 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
0
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
30 (226)
60 (531)
90 (1327)
120 (1062)
150 (1328)
180 (1593)
210 (1859)
240 (2124)
270 (2390)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Delivery (effective flow)
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery -l/min (USgpm)
0
20 (5)
40 (11)
60 (16)
80 (21)
100 (26)
0
10
20
30
40
50
60
70
80
90
100
Volumetric Efficiency
Delivery and Efficiency at 1000 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
0
10
20
30
40
50
60
70
80
90
100
20 (5)
40 (11)
60 (16)
80 (21)
100 (26)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1200 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
30 (226)
60 (531)
90 (1327)
120 (1062)
150 (1328)
180 (1593)
210 (1859)
Input To rque,
Full Stroke
Input Power,
Full Stroke
240 (2124)
270 (2390)
Outlet Pressure – bar (psi)
Input Torque and Power at 1000 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
0
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
30 (226)
60 (531)
90 (1327)
120 (1062)
150 (1328)
180 (1593)
210 (1859)
240 (2124)
270 (2390)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Overall Efficiency
Delivery (effective flow)
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery -l/min (USgpm)
0
20 (5)
40 (11)
60 (16)
80 (21)
100 (26)
0
10
20
30
40
50
60
70
80
90
100
Volumetric Efficiency
Delivery and Efficiency at 1000 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
0
10
20
30
40
50
60
70
80
90
100
20 (5)
40 (11)
60 (16)
80 (21)
100 (26)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1200 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
30 (226)
60 (531)
90 (1327)
120 (1062)
150 (1328)
180 (1593)
210 (1859)
Input To rque,
Full Stroke
Input Power,
Full Stroke
240 (2124)
270 (2390)
Outlet Pressure – bar (psi)
Input Torque and Power at 1000 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
0
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
30 (226)
60 (531)
90 (1327)
120 (1062)
150 (1328)
180 (1593)
210 (1859)
240 (2124)
270 (2390)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Overall Efficiency
Delivery (effective flow)
43EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Case Flow l/min - (USgpm)
Outlet Pressure - bar (psi)
Case Flow versus Outlet Pressure at 1800 r/min, Full Flow,
50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
1 (0.26)
2 (0.53)
3 (0.79)
4 (1.06)
5 (1.32)
Case Flow versus Outlet Pressure at Cutoff, 1800 r/min,
50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Case Flow l/min - (USgpm)
Outlet Pressure - bar (psi)
0
1 (0.26)
2 (0.53)
3 (0.79)
4 (1.06)
5 (1.32)
6 (1.59)
7 (1.85)
8 (2.11)
9 (2.38)
10 (2.64)
11 (2.91)
12 (3.17)
Performance
Industrial
PVM063
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery -l/min (USgpm)
0
20 (5)
40 (11)
60 (16)
80 (21)
100 (26)
0
10
20
30
40
50
60
70
80
90
100
Volumetric Efficiency
Delivery and Efficiency at 1000 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
0
10
20
30
40
50
60
70
80
90
100
20 (5)
40 (11)
60 (16)
80 (21)
100 (26)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1200 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
30 (226)
60 (531)
90 (1327)
120 (1062)
150 (1328)
180 (1593)
210 (1859)
Input To rque,
Full Stroke
Input Power,
Full Stroke
240 (2124)
270 (2390)
Outlet Pressure – bar (psi)
Input Torque and Power at 1000 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
0
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
30 (226)
60 (531)
90 (1327)
120 (1062)
150 (1328)
180 (1593)
210 (1859)
240 (2124)
270 (2390)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Overall Efficiency
Delivery (effective flow)
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery -l/min (USgpm)
0
20 (5)
40 (11)
60 (16)
80 (21)
100 (26)
0
10
20
30
40
50
60
70
80
90
100
Volumetric Efficiency
Delivery and Efficiency at 1000 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
0
10
20
30
40
50
60
70
80
90
100
20 (5)
40 (11)
60 (16)
80 (21)
100 (26)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1200 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
30 (226)
60 (531)
90 (1327)
120 (1062)
150 (1328)
180 (1593)
210 (1859)
Input To rque,
Full Stroke
Input Power,
Full Stroke
240 (2124)
270 (2390)
Outlet Pressure – bar (psi)
Input Torque and Power at 1000 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
0
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
30 (226)
60 (531)
90 (1327)
120 (1062)
150 (1328)
180 (1593)
210 (1859)
240 (2124)
270 (2390)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Overall Efficiency
Delivery (effective flow)
44 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance
Mobile
PVM063
Sound pressure data
equivalent to NFPA.
Noise Level – dBA
Typical Noise Levels at 2500 & 600 r/min with Petroleum Oil (10W)
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
50
55
60
65
70
75
80
2500 r/min
max. flow
2500 r/min
min. flow
600 r/min
max. flow
600 r/min
min. flow
Outlet Pressure – bar (psi)
85
Overall Efficiency (%)
Overall Efficiency versus Speed
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet
0 500 1000 1500 2000 2500
Speed – r/min
50
75
85
95
55
70
80
90
65
100
3000
50 bar (725 psi)
230 bar (3300 psi)
100 bar
(1450 psi)
150 bar
(2200 psi)
210 bar
(3000 psi)
60
Delivery and Case Flow versus Speed at 93°C (200°F),
Full Flow 1.0 bar absolute (0 psi gauge) Inlet
0
Speed (r/min)
Delivery – l/min (USgpm)
40 (11)
60 (16)
80 (21)
100 (26)
120 (32)
500 1000 1500 2000 2500
140 (37)
20 (5)
Case Flow – l/min (USgpm)
4 (1.06)
2 (0.53)
0
3000
50 bar (725 psi)
Delivery
210 bar (3000 psi) Case Flow
50 bar (725 psi) Case Flow
160 (42)
6 (1.59)
8 (2.11)
210 bar (3000 psi)
Delivery
Sound pressure data
equivalent to NFPA.
Noise Level – dBA
Typical Noise Levels at 2500 & 600 r/min with Petroleum Oil (10W)
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
50
55
60
65
70
75
80
2500 r/min
max. flow
2500 r/min
min. flow
600 r/min
max. flow
600 r/min
min. flow
Outlet Pressure – bar (psi)
85
Overall Efficiency (%)
Overall Efficiency versus Speed
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet
0 500 1000 1500 2000 2500
Speed – r/min
50
75
85
95
55
70
80
90
65
100
3000
50 bar (725 psi)
230 bar (3300 psi)
100 bar
(1450 psi)
150 bar
(2200 psi)
210 bar
(3000 psi)
60
Delivery and Case Flow versus Speed at 93°C (200°F),
Full Flow 1.0 bar absolute (0 psi gauge) Inlet
0
Speed (r/min)
Delivery – l/min (USgpm)
40 (11)
60 (16)
80 (21)
100 (26)
120 (32)
500 1000 1500 2000 2500
140 (37)
20 (5)
Case Flow – l/min (USgpm)
4 (1.06)
2 (0.53)
0
3000
50 bar (725 psi)
Delivery
210 bar (3000 psi) Case Flow
50 bar (725 psi) Case Flow
160 (42)
6 (1.59)
8 (2.11)
210 bar (3000 psi)
Delivery
Sound pressure data
equivalent to NFPA.
Noise Level – dBA
Typical Noise Levels at 2500 & 600 r/min with Petroleum Oil (10W)
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
50
55
60
65
70
75
80
2500 r/min
max. flow
2500 r/min
min. flow
600 r/min
max. flow
600 r/min
min. flow
Outlet Pressure – bar (psi)
85
Overall Efficiency (%)
Overall Efficiency versus Speed
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet
0 500 1000 1500 2000 2500
Speed – r/min
50
75
85
95
55
70
80
90
65
100
3000
50 bar (725 psi)
230 bar (3300 psi)
100 bar
(1450 psi)
150 bar
(2200 psi)
210 bar
(3000 psi)
60
Delivery and Case Flow versus Speed at 93°C (200°F),
Full Flow 1.0 bar absolute (0 psi gauge) Inlet
0
Speed (r/min)
Delivery – l/min (USgpm)
40 (11)
60 (16)
80 (21)
100 (26)
120 (32)
500 1000 1500 2000 2500
140 (37)
20 (5)
Case Flow – l/min (USgpm)
4 (1.06)
2 (0.53)
0
3000
50 bar (725 psi)
Delivery
210 bar (3000 psi) Case Flow
50 bar (725 psi) Case Flow
160 (42)
6 (1.59)
8 (2.11)
210 bar (3000 psi)
Delivery
45EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance
Mobile
PVM063
0 1000500 20001500
Speed (r/min)
2500
Input Torque – Nm (in.lb.)
Input Torque versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
3000
230 bar (3300 psi)
210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
17 bar (250 psi)
50 bar (725 psi)
0 1000500 20001500
Speed (r/min)
2500
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
90 (121)
Input Power versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
230 bar (3300 psi)
210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
17 bar (250 psi)
60 (80)
70 (94)
80 (107)
100 (134)
50 bar (725 psi)
Input Power – kW (hp)
Input Torque and Case Flow versus Speed
at 93°C (200°F), Load Sense Standby and
1.0 bar absolute (0 psi gauge) Inlet
0
Speed (r/min)
Input Torque – Nm (in.lb.)
2 (18)
3 (27)
4 (35)
5 (44)
6 (53)
500 1000 1500 2000 2500
1 (9)
Case Flow – l/min (USgpm)
6.0 (1.59)
0
3000
7 (62)
8 (71)
11 bar (160 psi) diff.
Input Torque
8.0 (2.11)
10.0 (2.64)
12.0 (3.17)
14.0 (3.70)
16.0 (4.23)
18.0 (4.76)
20.0 (5.28)
20 bar (300 psi)
diff. Input Torque
11 bar (160 psi) diff.
Case Flow
20 bar (300 psi)
diff. Case Flow
2.0 (.53)
4.0 (1.06)
0
Input Torque and Case Flow versus Speed
at 93°C (200°F), Pressure Limit Cut-off and 1.0 bar
absolute (0 psi gauge) Inlet
10 (88)
20 (177)
30 (265)
40 (354)
500 1000 1500 2000 2500 3000
Input Torque – Nm (in.lb.)
50 (442)
60 (531)
210 bar (3000 psi) Input To rque
150 bar (2200 psi) Input Torque
Speed (r/min)
2.0 (.53)
Case Flow – l/min (USgpm)
150 bar (2200 psi)
Case Flow
70 (619)
80 (708)
4.0 (1.06)
6.0 (1.59)
8.0 (2.11)
10.0 (2.64)
12.0 (3.17)
14.0 (3.70)
16.0 (4.23)
18.0 (4.76)
20.0 (5.28)
210 bar (3000 psi) Case Flow
0 1000500 20001500
Speed (r/min)
2500
Input Torque – Nm (in.lb.)
Input Torque versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
3000
230 bar (3300 psi)
210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
17 bar (250 psi)
50 bar (725 psi)
0 1000500 20001500
Speed (r/min)
2500
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
90 (121)
Input Power versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
230 bar (3300 psi)
210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
17 bar (250 psi)
60 (80)
70 (94)
80 (107)
100 (134)
50 bar (725 psi)
Input Power – kW (hp)
Input Torque and Case Flow versus Speed
at 93°C (200°F), Load Sense Standby and
1.0 bar absolute (0 psi gauge) Inlet
0
Speed (r/min)
Input Torque – Nm (in.lb.)
2 (18)
3 (27)
4 (35)
5 (44)
6 (53)
500 1000 1500 2000 2500
1 (9)
Case Flow – l/min (USgpm)
6.0 (1.59)
0
3000
7 (62)
8 (71)
11 bar (160 psi) diff.
Input Torque
8.0 (2.11)
10.0 (2.64)
12.0 (3.17)
14.0 (3.70)
16.0 (4.23)
18.0 (4.76)
20.0 (5.28)
20 bar (300 psi)
diff. Input Torque
11 bar (160 psi) diff.
Case Flow
20 bar (300 psi)
diff. Case Flow
2.0 (.53)
4.0 (1.06)
0
Input Torque and Case Flow versus Speed
at 93°C (200°F), Pressure Limit Cut-off and 1.0 bar
absolute (0 psi gauge) Inlet
10 (88)
20 (177)
30 (265)
40 (354)
500 1000 1500 2000 2500 3000
Input Torque – Nm (in.lb.)
50 (442)
60 (531)
210 bar (3000 psi) Input To rque
150 bar (2200 psi) Input Torque
Speed (r/min)
2.0 (.53)
Case Flow – l/min (USgpm)
150 bar (2200 psi)
Case Flow
70 (619)
80 (708)
4.0 (1.06)
6.0 (1.59)
8.0 (2.11)
10.0 (2.64)
12.0 (3.17)
14.0 (3.70)
16.0 (4.23)
18.0 (4.76)
20.0 (5.28)
210 bar (3000 psi) Case Flow
0 1000500 20001500
Speed (r/min)
2500
Input Torque – Nm (in.lb.)
Input Torque versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
3000
230 bar (3300 psi)
210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
17 bar (250 psi)
50 bar (725 psi)
0 1000500 20001500
Speed (r/min)
2500
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
90 (121)
Input Power versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
230 bar (3300 psi)
210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
17 bar (250 psi)
60 (80)
70 (94)
80 (107)
100 (134)
50 bar (725 psi)
Input Power – kW (hp)
Input Torque and Case Flow versus Speed
at 93°C (200°F), Load Sense Standby and
1.0 bar absolute (0 psi gauge) Inlet
0
Speed (r/min)
Input Torque – Nm (in.lb.)
2 (18)
3 (27)
4 (35)
5 (44)
6 (53)
500 1000 1500 2000 2500
1 (9)
Case Flow – l/min (USgpm)
6.0 (1.59)
0
3000
7 (62)
8 (71)
11 bar (160 psi) diff.
Input Torque
8.0 (2.11)
10.0 (2.64)
12.0 (3.17)
14.0 (3.70)
16.0 (4.23)
18.0 (4.76)
20.0 (5.28)
20 bar (300 psi)
diff. Input Torque
11 bar (160 psi) diff.
Case Flow
20 bar (300 psi)
diff. Case Flow
2.0 (.53)
4.0 (1.06)
0
Input Torque and Case Flow versus Speed
at 93°C (200°F), Pressure Limit Cut-off and 1.0 bar
absolute (0 psi gauge) Inlet
10 (88)
20 (177)
30 (265)
40 (354)
500 1000 1500 2000 2500 3000
Input Torque – Nm (in.lb.)
50 (442)
60 (531)
210 bar (3000 psi) Input To rque
150 bar (2200 psi) Input Torque
Speed (r/min)
2.0 (.53)
Case Flow – l/min (USgpm)
150 bar (2200 psi)
Case Flow
70 (619)
80 (708)
4.0 (1.06)
6.0 (1.59)
8.0 (2.11)
10.0 (2.64)
12.0 (3.17)
14.0 (3.70)
16.0 (4.23)
18.0 (4.76)
20.0 (5.28)
210 bar (3000 psi) Case Flow
0 1000500 20001500
Speed (r/min)
2500
Input Torque – Nm (in.lb.)
Input Torque versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
3000
230 bar (3300 psi)
210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
17 bar (250 psi)
50 bar (725 psi)
0 1000500 20001500
Speed (r/min)
2500
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
90 (121)
Input Power versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
230 bar (3300 psi)
210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
17 bar (250 psi)
60 (80)
70 (94)
80 (107)
100 (134)
50 bar (725 psi)
Input Power – kW (hp)
Input Torque and Case Flow versus Speed
at 93°C (200°F), Load Sense Standby and
1.0 bar absolute (0 psi gauge) Inlet
0
Speed (r/min)
Input Torque – Nm (in.lb.)
2 (18)
3 (27)
4 (35)
5 (44)
6 (53)
500 1000 1500 2000 2500
1 (9)
Case Flow – l/min (USgpm)
6.0 (1.59)
0
3000
7 (62)
8 (71)
11 bar (160 psi) diff.
Input Torque
8.0 (2.11)
10.0 (2.64)
12.0 (3.17)
14.0 (3.70)
16.0 (4.23)
18.0 (4.76)
20.0 (5.28)
20 bar (300 psi)
diff. Input Torque
11 bar (160 psi) diff.
Case Flow
20 bar (300 psi)
diff. Case Flow
2.0 (.53)
4.0 (1.06)
0
Input Torque and Case Flow versus Speed
at 93°C (200°F), Pressure Limit Cut-off and 1.0 bar
absolute (0 psi gauge) Inlet
10 (88)
20 (177)
30 (265)
40 (354)
500 1000 1500 2000 2500 3000
Input Torque – Nm (in.lb.)
50 (442)
60 (531)
210 bar (3000 psi) Input To rque
150 bar (2200 psi) Input Torque
Speed (r/min)
2.0 (.53)
Case Flow – l/min (USgpm)
150 bar (2200 psi)
Case Flow
70 (619)
80 (708)
4.0 (1.06)
6.0 (1.59)
8.0 (2.11)
10.0 (2.64)
12.0 (3.17)
14.0 (3.70)
16.0 (4.23)
18.0 (4.76)
20.0 (5.28)
210 bar (3000 psi) Case Flow
46 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
400 (3540)
360 (3186)
320 (2832)
280 (2478)
240 (2124)
200 (1770)
160 (1416)
120 (1062)
80 (708)
40 (354)
0
Input Torque – Nm (in.lb.)
80 (107)
60 (80)
40 (54)
20 (27)
0
Input Power – kW (hp)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Input Torque,
Cut-off
Input Torque and Power at 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
150 (40)
125 (33)
100 (26)
75 (20)
50 (13)
25 (7)
0
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
400 (3540)
360 (3186)
320 (2832)
280 (2478)
240 (2124)
200 (1770)
160 (1416)
120 (1062)
80 (708)
40 (354)
0
Input Torque – Nm (in.lb.)
80 (107)
60 (80)
40 (54)
20 (27)
0
Input Power – kW (hp)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Input Torque,
Cut-off
Input Torque and Power at 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
150 (40)
125 (33)
100 (26)
75 (20)
50 (13)
25 (7)
0
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
Performance
Industrial
PVM074
72
70
68
66
64
62
60
58
56
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
Outlet Pressure – bar (psi)
76
74
72
70
68
66
64
62
60
58
Noise Level – dBA
Sound pressure data
equivalent to NFPA.
Typical Noise Levels at 1800 and 1200 r/min
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
1200 r/min
Min. Flow
1200 r/min
Max. Flow
1800 r/min
Min. Flow
1800 r/min
Max. Flow
Noise Level – dBA
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
Outlet Pressure – bar (psi)
Typical Noise Levels at 1500 and 1000 r/min
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
1500 r/min
Max. Flow
1000 r/min
Min. Flow
1500 r/min
Min. Flow
1000 r/min
Max. Flow
72
70
68
66
64
62
60
58
56
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
Outlet Pressure – bar (psi)
76
74
72
70
68
66
64
62
60
58
Noise Level – dBA
Sound pressure data
equivalent to NFPA.
Typical Noise Levels at 1800 and 1200 r/min
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
1200 r/min
Min. Flow
1200 r/min
Max. Flow
1800 r/min
Min. Flow
1800 r/min
Max. Flow
Noise Level – dBA
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
Outlet Pressure – bar (psi)
Typical Noise Levels at 1500 and 1000 r/min
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
1500 r/min
Max. Flow
1000 r/min
Min. Flow
1500 r/min
Min. Flow
1000 r/min
Max. Flow
47EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Input Torque and Power at 1200 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
400 (3540)
360 (3186)
320 (2832)
280 (2478)
240 (2124)
200 (1770)
160 (1416)
120 (1062)
80 (708)
40 (354)
0
80 (107)
60 (80)
40 (54)
20 (27)
0
125 (33)
100 (26)
75 (20)
50 (13)
25 (7)
0
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Input Torque and Power at 1200 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
400 (3540)
360 (3186)
320 (2832)
280 (2478)
240 (2124)
200 (1770)
160 (1416)
120 (1062)
80 (708)
40 (354)
0
80 (107)
60 (80)
40 (54)
20 (27)
0
125 (33)
100 (26)
75 (20)
50 (13)
25 (7)
0
Performance
Industrial
PVM074
125 (33)
100 (26)
75 (20)
50 (13)
25 (7)
0
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1500 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Input Torque and Power at 1500 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
400 (3540)
360 (3186)
320 (2832)
280 (2478)
240 (2124)
200 (1770)
160 (1416)
120 (1062)
80 (708)
40 (354)
0
80 (107)
60 (80)
40 (54)
20 (27)
0
125 (33)
100 (26)
75 (20)
50 (13)
25 (7)
0
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1500 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Input Torque and Power at 1500 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
400 (3540)
360 (3186)
320 (2832)
280 (2478)
240 (2124)
200 (1770)
160 (1416)
120 (1062)
80 (708)
40 (354)
0
80 (107)
60 (80)
40 (54)
20 (27)
0
48 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
5,0 (1.32)
4,5 (1.19)
4,0 (1.06)
3,5 (0.92)
3,0 (0.79)
2,5 (0.66)
2,0 (0.53)
1,5 (0.40)
1,0 (0.26)
0,5 (0.13)
0
12 (3.17)
Case Flow Versus Outlet Pressure at Full Flow, 1800 r/min
50°C (120° F) and 1.0 bar absolute (0 psi gauge) Inlet
Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min
50°C (120° F) and 1.0 bar absolute (0 psi gauge) Inlet
0
100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
Case Flow - l/min (USgpm)
Case Flow - l/min (USgpm)
250
(3600)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure - bar (psi)
250
(3600)
11 (2.91)
10 (2.64)
9 (2.38)
8 (2.11)
7 (1.85)
5,0 (1.32)
4,5 (1.19)
4,0 (1.06)
3,5 (0.92)
3,0 (0.79)
2,5 (0.66)
2,0 (0.53)
1,5 (0.40)
1,0 (0.26)
0,5 (0.13)
0
12 (3.17)
Case Flow Versus Outlet Pressure at Full Flow, 1800 r/min
50°C (120° F) and 1.0 bar absolute (0 psi gauge) Inlet
Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min
50°C (120° F) and 1.0 bar absolute (0 psi gauge) Inlet
0
100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
Case Flow - l/min (USgpm)
Case Flow - l/min (USgpm)
250
(3600)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure - bar (psi)
250
(3600)
11 (2.91)
10 (2.64)
9 (2.38)
8 (2.11)
7 (1.85)
Performance
Industrial
PVM074
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Input Torque and Power at 1000 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
400 (3540)
360 (3186)
320 (2832)
280 (2478)
240 (2124)
200 (1770)
160 (1416)
120 (1062)
80 (708)
40 (354)
0
80 (107)
60 (80)
40 (54)
20 (27)
0
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1000 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100 (26)
75 (20)
50 (13)
25 (7)
0
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Input Torque and Power at 1000 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
400 (3540)
360 (3186)
320 (2832)
280 (2478)
240 (2124)
200 (1770)
160 (1416)
120 (1062)
80 (708)
40 (354)
0
80 (107)
60 (80)
40 (54)
20 (27)
0
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1000 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100 (26)
75 (20)
50 (13)
25 (7)
0
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
49EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
160 (42)
120 (32)
80 (21)
40 (11)
0
0 500 1000 1500 2000 2500
2 (0.5)
4 (1.1)
6 (1.6)
8 (2.1)
Speed – r/min
50 bar (700 psi),
Delivery
280 bar (4000 psi),
Delivery
280 bar (4000 psi), Case flow
50 bar (700 psi), Case flow
20 (5)
60 (16)
100 (26)
140 (37)
180 (48)
0
Case Flow – l/min (USgpm)
Delivery – l/min (USgpm)
Input Torque – Nm (in.lb.)
Delivery and Case Flow Versus Speed
@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi) gauge Inlet
350 (3097)
300 (2655)
250 (2212)
200 (1770)
150 (1327)
100 (885)
50 (442)
Speed – r/min
0
0 500 1000 1500 2000 2500
50 bar (700 psi)
17 bar (250 psi)
400 (3540)
Input Torque Versus Speed
@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi gauge) inlet
320 bar (4600 psi)
250 bar (3600 psi)
150 bar (2200 psi)
200 bar (2900 psi)
280 bar (4000 psi)
100 bar (1500 psi)
Pressure – bar (psi)
70 (94)
60 (80)
50 (67)
40 (54)
30 (40)
20 (27)
10 (13)
100 (134)
90 (121)
80 (107)
0
500 1000 1500 2000 2500
Input Power @ Full Flow – kW (hp)
Speed – r/min
Input Power Versus Speed
93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet
280 (4000)
250 (3600)
200 (2900)
150 (2200)
100 (1500)
50 (700)
17 (250)
320 (4600)
Pressure – bar (psi)
0
Performance
Mobile
PVM074
0 500 1000 1500 2000 2500
Efficiency – %
Speed – r/min
250 bar
(3600 psi)
200 bar
(2900psi)
100 bar
(1500 psi)
50 bar
(700 psi)
320 bar
(4600 psi)
280 bar
(4000 psi)
150 bar
(2200 psi)
95
90
85
80
75
70
65
60
Overall Efficiency Versus Speed
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
84
80
76
72
68
64
60
56
52
Noise Level – dBA
Typical Noise Levels
Petroleum Oil (10W) at 93°C (200°F),
1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
Outlet Pressure – bar (psi)
(Sound pressure data equivalent to NFPA)
2400 r/min
Min. Flow
2400 r/min
Max. Flow
600 r/min
Max. Flow
600 r/min
Min. Flow
0 500 1000 1500 2000 2500
Efficiency – %
Speed – r/min
250 bar
(3600 psi)
200 bar
(2900psi)
100 bar
(1500 psi)
50 bar
(700 psi)
320 bar
(4600 psi)
280 bar
(4000 psi)
150 bar
(2200 psi)
95
90
85
80
75
70
65
60
Overall Efficiency Versus Speed
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
84
80
76
72
68
64
60
56
52
Noise Level – dBA
Typical Noise Levels
Petroleum Oil (10W) at 93°C (200°F),
1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
Outlet Pressure – bar (psi)
(Sound pressure data equivalent to NFPA)
2400 r/min
Min. Flow
2400 r/min
Max. Flow
600 r/min
Max. Flow
600 r/min
Min. Flow
50 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance
Mobile
PVM074
20 bar (300 psi) differential,
Input Torque
11 bar (160 psi) differential
Case Flow
20 bar (300 psi) differential
Case Flow
Speed – r/min
Input Torque – Nm (in.lb.)
Case Flow – l/min (USgpm)
8.0 (2.11)
6.0 (1.58)
2.0 (0.53)
0
4.0 (1.06)
6 (53)
4 (35)
2 (18)
0
0 500 1000 1500 2000 2500
1 (9)
3 (27)
5 (44)
7 (62)
11 bar (160) differential
Input Torque
Input Torque and Case Flow Versus Speed
@ 93°C (200°F), load sense standby and
1.0 bar absolute (0 psi gauge) inlet
160 (1416)
140 (1239)
120 (1062)
100 (885)
80 (708)
60 (531)
40 (354)
20 (177)
0
0
500
1000
1500
2000
2500
0
10 (2.6)
20 (5.3)
30 (7.9)
Case Flow – l/min (USgpm)
Speed – r/min
280 bar (4000 psi),
Input Torque
150 bar (2200 psi),
Input Torque
280 bar (4000 psi), Case Flow
Input Torque – Nm (in.lb.)
150 bar (2200 psi), Case Flow
Input Torque and Case Flow Versus Speed
@ 93°C (200°F), cut-off and
1.0 bar absolute (0 psi gauge) inlet
20 bar (300 psi) differential,
Input Torque
11 bar (160 psi) differential
Case Flow
20 bar (300 psi) differential
Case Flow
Speed – r/min
Input Torque – Nm (in.lb.)
Case Flow – l/min (USgpm)
8.0 (2.11)
6.0 (1.58)
2.0 (0.53)
0
4.0 (1.06)
6 (53)
4 (35)
2 (18)
0
0 500 1000 1500 2000 2500
1 (9)
3 (27)
5 (44)
7 (62)
11 bar (160) differential
Input Torque
Input Torque and Case Flow Versus Speed
@ 93°C (200°F), load sense standby and
1.0 bar absolute (0 psi gauge) inlet
160 (1416)
140 (1239)
120 (1062)
100 (885)
80 (708)
60 (531)
40 (354)
20 (177)
0
0
500
1000
1500
2000
2500
0
10 (2.6)
20 (5.3)
30 (7.9)
Case Flow – l/min (USgpm)
Speed – r/min
280 bar (4000 psi),
Input Torque
150 bar (2200 psi),
Input Torque
280 bar (4000 psi), Case Flow
Input Torque – Nm (in.lb.)
150 bar (2200 psi), Case Flow
Input Torque and Case Flow Versus Speed
@ 93°C (200°F), cut-off and
1.0 bar absolute (0 psi gauge) inlet
51EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
150 (40)
Overall Efficiency
Delivery (effective flow)
Delivery and Efficiency at 1500 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1800 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Input Torque,
Cut-off
Outlet Pressure – bar (psi)
Input Torque and Power at 1500 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
250
(3600)
Input Torque – Nm (in.lb.)
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Input Power – kW (hp)
Volumetric Efficiency
Volumetric Efficiency
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
150 (40)
Overall Efficiency
Delivery (effective flow)
Delivery and Efficiency at 1500 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1800 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Input Torque,
Cut-off
Outlet Pressure – bar (psi)
Input Torque and Power at 1500 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
250
(3600)
Input Torque – Nm (in.lb.)
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Input Power – kW (hp)
Volumetric Efficiency
Volumetric Efficiency
Performance
Industrial
PVM081
Noise Level – dBA
Typical Noise Levels at 1800 and 1200 r/min. with
Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
58
60
64
66
68
1800 r/min
min. flow
70
72
74
1200 r/min
max. flow
62
1800 r/min
max. flow
Typical Noise Levels at 1500 and 1000 r/min. with
Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
Noise Level – dBA
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
Sound pressure data
equivalent to NFPA.
56
58
60
62
64
66
68
70
72
1500 r/min
max. flow
1500 r/min
min. flow
1000 r/min
max. flow
1200 r/min
min. flow
1000 r/min
min. flow
Noise Level – dBA
Typical Noise Levels at 1800 and 1200 r/min. with
Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
58
60
64
66
68
1800 r/min
min. flow
70
72
74
1200 r/min
max. flow
62
1800 r/min
max. flow
Typical Noise Levels at 1500 and 1000 r/min. with
Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
Noise Level – dBA
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
Sound pressure data
equivalent to NFPA.
56
58
60
62
64
66
68
70
72
1500 r/min
max. flow
1500 r/min
min. flow
1000 r/min
max. flow
1200 r/min
min. flow
1000 r/min
min. flow
52 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
Delivery and Efficiency at 1000 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1200 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Outlet Pressure – bar (psi)
Input Torque and Power at 1000 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
250
(3600)
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Input Power – kW (hp)
Volumetric Efficiency
Volumetric Efficiency
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
Delivery and Efficiency at 1000 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1200 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Outlet Pressure – bar (psi)
Input Torque and Power at 1000 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
250
(3600)
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Input Power – kW (hp)
Volumetric Efficiency
Volumetric Efficiency
Performance
Industrial
PVM081
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
150 (40)
Overall Efficiency
Delivery (effective flow)
Delivery and Efficiency at 1500 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1800 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Input Torque,
Cut-off
Outlet Pressure – bar (psi)
Input Torque and Power at 1500 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
250
(3600)
Input Torque – Nm (in.lb.)
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Input Power – kW (hp)
Volumetric Efficiency
Volumetric Efficiency
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
150 (40)
Overall Efficiency
Delivery (effective flow)
Delivery and Efficiency at 1500 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1800 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Input Torque,
Cut-off
Outlet Pressure – bar (psi)
Input Torque and Power at 1500 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
250
(3600)
Input Torque – Nm (in.lb.)
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Input Power – kW (hp)
Volumetric Efficiency
Volumetric Efficiency
53EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Case Flow l/min - (USgpm)
Outlet Pressure - bar (psi)
Case Flow versus Outlet Pressure at 1800 r/min, Full Flow,
50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
0.5 (0.13)
1.0 (0.26)
1.5 (0.4)
2.0 (0.53)
2.5 (0.66)
3.0 (0.79)
3.5 (0.92)
4.0 (1.06)
Case Flow versus Outlet Pressure at Cutoff, 1800 r/min,
50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Case Flow l/min - (USgpm)
Outlet Pressure - bar (psi)
0
11 (2.91)
12 (3.17)
14 (3.70)
15 (3.96)
17 (4.49)
18 (4.76)
13 (3.43)
16 (4.23)
19 (5.02)
20 (5.28)
21 (5.55)
Performance
Industrial
PVM081
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
Delivery and Efficiency at 1000 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1200 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Outlet Pressure – bar (psi)
Input Torque and Power at 1000 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
250
(3600)
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Input Power – kW (hp)
Volumetric Efficiency
Volumetric Efficiency
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
Delivery and Efficiency at 1000 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1200 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Outlet Pressure – bar (psi)
Input Torque and Power at 1000 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
250
(3600)
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Input Power – kW (hp)
Volumetric Efficiency
Volumetric Efficiency
54 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Sound pressure data
equivalent to NFPA.
Noise Level – dBA
Typical Noise Levels at 2400 & 600 r/min
with Petroleum Oil (10W) at 93°C (200°F)
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
54
58
62
66
70
74
78
2400 r/min
min. flow
2400 r/min
max. flow
600 r/min
min. flow
Outlet Pressure – bar (psi)
82
Overall Efficiency (%)
Overall Efficiency versus Speed
at 93°C (200°F) and 1.0 bar absolute
(0 psi gauge) inlet
0
500 1000 1500 2000 2500
Speed – r/min
50
75
85
95
55
70
80
90
65
100
3000
50 bar (725 psi)
100 bar
(1450 psi)
150 bar
(2200 psi)
200 bar
(2900 psi)
60
230 bar (3300 psi)
Delivery and Case Flow versus Speed
at 93°C (200°F), Full Flow 1.0 bar absolute
(0 psi gauge) Inlet
0
Speed (r/min)
Delivery – l/min (USgpm)
40 (11)
60 (16)
80 (21)
100 (26)
120 (32)
500 1000 1500 2000 2500
140 (37)
20 (5)
4 (1.06)
2 (0.53)
0
3000
50 bar (725 psi) Case Flow
160 (42)
6 (1.59)
8 (2.11)
210 bar (3000
psi) Delivery
200 (53)
180 (48)
Case Flow
l/min
(USgpm)
210 bar (3000 psi) Case Flow
50 bar (725
psi) Delivery
600 r/min
max. flow
Sound pressure data
equivalent to NFPA.
Noise Level – dBA
Typical Noise Levels at 2400 & 600 r/min
with Petroleum Oil (10W) at 93°C (200°F)
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
54
58
62
66
70
74
78
2400 r/min
min. flow
2400 r/min
max. flow
600 r/min
min. flow
Outlet Pressure – bar (psi)
82
Overall Efficiency (%)
Overall Efficiency versus Speed
at 93°C (200°F) and 1.0 bar absolute
(0 psi gauge) inlet
0
500 1000 1500 2000 2500
Speed – r/min
50
75
85
95
55
70
80
90
65
100
3000
50 bar (725 psi)
100 bar
(1450 psi)
150 bar
(2200 psi)
200 bar
(2900 psi)
60
230 bar (3300 psi)
Delivery and Case Flow versus Speed
at 93°C (200°F), Full Flow 1.0 bar absolute
(0 psi gauge) Inlet
0
Speed (r/min)
Delivery – l/min (USgpm)
40 (11)
60 (16)
80 (21)
100 (26)
120 (32)
500 1000 1500 2000 2500
140 (37)
20 (5)
4 (1.06)
2 (0.53)
0
3000
50 bar (725 psi) Case Flow
160 (42)
6 (1.59)
8 (2.11)
210 bar (3000
psi) Delivery
200 (53)
180 (48)
Case Flow
l/min
(USgpm)
210 bar (3000 psi) Case Flow
50 bar (725
psi) Delivery
600 r/min
max. flow
Performance
Mobile
PVM081
Sound pressure data
equivalent to NFPA.
Noise Level – dBA
Typical Noise Levels at 2400 & 600 r/min
with Petroleum Oil (10W) at 93°C (200°F)
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
54
58
62
66
70
74
78
2400 r/min
min. flow
2400 r/min
max. flow
600 r/min
min. flow
Outlet Pressure – bar (psi)
82
Overall Efficiency (%)
Overall Efficiency versus Speed
at 93°C (200°F) and 1.0 bar absolute
(0 psi gauge) inlet
0
500 1000 1500 2000 2500
Speed – r/min
50
75
85
95
55
70
80
90
65
100
3000
50 bar (725 psi)
100 bar
(1450 psi)
150 bar
(2200 psi)
200 bar
(2900 psi)
60
230 bar (3300 psi)
Delivery and Case Flow versus Speed
at 93°C (200°F), Full Flow 1.0 bar absolute
(0 psi gauge) Inlet
0
Speed (r/min)
Delivery – l/min (USgpm)
40 (11)
60 (16)
80 (21)
100 (26)
120 (32)
500 1000 1500 2000 2500
140 (37)
20 (5)
4 (1.06)
2 (0.53)
0
3000
50 bar (725 psi) Case Flow
160 (42)
6 (1.59)
8 (2.11)
210 bar (3000
psi) Delivery
200 (53)
180 (48)
Case Flow
l/min
(USgpm)
210 bar (3000 psi) Case Flow
50 bar (725
psi) Delivery
600 r/min
max. flow
55EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance
Mobile
PVM081
0 1000500 20001500
Speed (r/min)
2500
Input Torque – Nm (in.lb.)
Input Torque versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
3000
210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
17 bar (250 psi)
50 bar (725 psi)
350 (2655)
230 bar (3300 psi)
0 1000500 20001500
Speed (r/min)
2500
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
90 (121)
Input Power versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
60 (80)
70 (94)
80 (107)
100 (134)
200 bar (2900 psi)
230 bar (3300 psi)
150 bar (2200 psi)
100 bar (1500 psi)
50 bar (725 psi)
17 bar (250 psi)
Input Power – kW (hp)
Input Torque and Case Flow versus Speed at 93°C
(200°F), Load Sense Standby and 1.0 bar absolute
(0 psi gauge) Inlet
0
Speed (r/min)
Input Torque – Nm (in.lb.)
2 (18)
3 (27)
4 (35)
5 (44)
6 (53)
500 1000 1500 2000 2500
1 (9)
3000
7 (62)
8 (71)
11 bar (160 psi) diff.
Input Torque
8.0 (2.11)
10.0 (2.64)
20 bar (300 psi)
diff. Case Flow
9 (80)
2.0 (0.53)
Case
Flow l/min
(USgpm)
20 bar (300 psi)
diff. Input Torque
11 bar (160 psi) diff.
Case Flow
6.0 (1.59)
4.0 (1.06)
0
Input Torque and Case Flow versus Speed at 93°C
(200°F), Pressure Limit Cut-off and 1.0 bar absolute
(0 psi gauge) Inlet
10 (88)
20 (177)
30 (265)
40 (354)
500
1000
1500
2000
2500
3000
Input Torque – Nm (in.lb.)
50 (442)
60 (531)
Speed (r/min)
Case Flow – l/min (USgpm)
150 bar
(2200 psi)
Case Flow
70 (619)
80 (708)
4.0 (1.06)
6.0 (1.59)
8.0 (2.11)
210 bar
(3000 psi)
Case
Flow
210 bar (3000 psi) Input Torque
150 bar
(2200 psi)
Input
Torque
2.0 (.53)
0 1000500 20001500
Speed (r/min)
2500
Input Torque – Nm (in.lb.)
Input Torque versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
3000
210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
17 bar (250 psi)
50 bar (725 psi)
350 (2655)
230 bar (3300 psi)
0 1000500 20001500
Speed (r/min)
2500
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
90 (121)
Input Power versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
60 (80)
70 (94)
80 (107)
100 (134)
200 bar (2900 psi)
230 bar (3300 psi)
150 bar (2200 psi)
100 bar (1500 psi)
50 bar (725 psi)
17 bar (250 psi)
Input Power – kW (hp)
Input Torque and Case Flow versus Speed at 93°C
(200°F), Load Sense Standby and 1.0 bar absolute
(0 psi gauge) Inlet
0
Speed (r/min)
Input Torque – Nm (in.lb.)
2 (18)
3 (27)
4 (35)
5 (44)
6 (53)
500 1000 1500 2000 2500
1 (9)
3000
7 (62)
8 (71)
11 bar (160 psi) diff.
Input Torque
8.0 (2.11)
10.0 (2.64)
20 bar (300 psi)
diff. Case Flow
9 (80)
2.0 (0.53)
Case
Flow l/min
(USgpm)
20 bar (300 psi)
diff. Input Torque
11 bar (160 psi) diff.
Case Flow
6.0 (1.59)
4.0 (1.06)
0
Input Torque and Case Flow versus Speed at 93°C
(200°F), Pressure Limit Cut-off and 1.0 bar absolute
(0 psi gauge) Inlet
10 (88)
20 (177)
30 (265)
40 (354)
500
1000
1500
2000
2500
3000
Input Torque – Nm (in.lb.)
50 (442)
60 (531)
Speed (r/min)
Case Flow – l/min (USgpm)
150 bar
(2200 psi)
Case Flow
70 (619)
80 (708)
4.0 (1.06)
6.0 (1.59)
8.0 (2.11)
210 bar
(3000 psi)
Case
Flow
210 bar (3000 psi) Input Torque
150 bar
(2200 psi)
Input
Torque
2.0 (.53)
0 1000500 20001500
Speed (r/min)
2500
Input Torque – Nm (in.lb.)
Input Torque versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
3000
210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
17 bar (250 psi)
50 bar (725 psi)
350 (2655)
230 bar (3300 psi)
0 1000500 20001500
Speed (r/min)
2500
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
90 (121)
Input Power versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
60 (80)
70 (94)
80 (107)
100 (134)
200 bar (2900 psi)
230 bar (3300 psi)
150 bar (2200 psi)
100 bar (1500 psi)
50 bar (725 psi)
17 bar (250 psi)
Input Power – kW (hp)
Input Torque and Case Flow versus Speed at 93°C
(200°F), Load Sense Standby and 1.0 bar absolute
(0 psi gauge) Inlet
0
Speed (r/min)
Input Torque – Nm (in.lb.)
2 (18)
3 (27)
4 (35)
5 (44)
6 (53)
500 1000 1500 2000 2500
1 (9)
3000
7 (62)
8 (71)
11 bar (160 psi) diff.
Input Torque
8.0 (2.11)
10.0 (2.64)
20 bar (300 psi)
diff. Case Flow
9 (80)
2.0 (0.53)
Case
Flow l/min
(USgpm)
20 bar (300 psi)
diff. Input Torque
11 bar (160 psi) diff.
Case Flow
6.0 (1.59)
4.0 (1.06)
0
Input Torque and Case Flow versus Speed at 93°C
(200°F), Pressure Limit Cut-off and 1.0 bar absolute
(0 psi gauge) Inlet
10 (88)
20 (177)
30 (265)
40 (354)
500
1000
1500
2000
2500
3000
Input Torque – Nm (in.lb.)
50 (442)
60 (531)
Speed (r/min)
Case Flow – l/min (USgpm)
150 bar
(2200 psi)
Case Flow
70 (619)
80 (708)
4.0 (1.06)
6.0 (1.59)
8.0 (2.11)
210 bar
(3000 psi)
Case
Flow
210 bar (3000 psi) Input Torque
150 bar
(2200 psi)
Input
Torque
2.0 (.53)
0 1000500 20001500
Speed (r/min)
2500
Input Torque – Nm (in.lb.)
Input Torque versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
3000
210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
17 bar (250 psi)
50 bar (725 psi)
350 (2655)
230 bar (3300 psi)
0 1000500 20001500
Speed (r/min)
2500
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
90 (121)
Input Power versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
60 (80)
70 (94)
80 (107)
100 (134)
200 bar (2900 psi)
230 bar (3300 psi)
150 bar (2200 psi)
100 bar (1500 psi)
50 bar (725 psi)
17 bar (250 psi)
Input Power – kW (hp)
Input Torque and Case Flow versus Speed at 93°C
(200°F), Load Sense Standby and 1.0 bar absolute
(0 psi gauge) Inlet
0
Speed (r/min)
Input Torque – Nm (in.lb.)
2 (18)
3 (27)
4 (35)
5 (44)
6 (53)
500 1000 1500 2000 2500
1 (9)
3000
7 (62)
8 (71)
11 bar (160 psi) diff.
Input Torque
8.0 (2.11)
10.0 (2.64)
20 bar (300 psi)
diff. Case Flow
9 (80)
2.0 (0.53)
Case
Flow l/min
(USgpm)
20 bar (300 psi)
diff. Input Torque
11 bar (160 psi) diff.
Case Flow
6.0 (1.59)
4.0 (1.06)
0
Input Torque and Case Flow versus Speed at 93°C
(200°F), Pressure Limit Cut-off and 1.0 bar absolute
(0 psi gauge) Inlet
10 (88)
20 (177)
30 (265)
40 (354)
500
1000
1500
2000
2500
3000
Input Torque – Nm (in.lb.)
50 (442)
60 (531)
Speed (r/min)
Case Flow – l/min (USgpm)
150 bar
(2200 psi)
Case Flow
70 (619)
80 (708)
4.0 (1.06)
6.0 (1.59)
8.0 (2.11)
210 bar
(3000 psi)
Case
Flow
210 bar (3000 psi) Input Torque
150 bar
(2200 psi)
Input
Torque
2.0 (.53)
56 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
550 (4867)
500 (4425)
450 (3982)
400 (3540)
350 (3097)
300 (2655)
250 (2212)
200 (1770)
150 (1327)
100 (885)
50 (442)
0
100 (134)
75 (101)
50 (67)
25 (34)
0
Input Torque,
Full Stroke
Input Power,
Full Stroke
Input Torque,
Cut-off
Input Torque and Power at 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure - bar (psi)
250
(3600)
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Outlet Pressure - bar (psi)
Delivery and Efficiency at 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
200 (53)
150 (40)
100 (26)
50 (13)
0
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
Delivery -l/min (USgpm)
Input Torque - Nm (in.lb.)
Efficiency - %
Input Power - kW (hp)
550 (4867)
500 (4425)
450 (3982)
400 (3540)
350 (3097)
300 (2655)
250 (2212)
200 (1770)
150 (1327)
100 (885)
50 (442)
0
100 (134)
75 (101)
50 (67)
25 (34)
0
Input Torque,
Full Stroke
Input Power,
Full Stroke
Input Torque,
Cut-off
Input Torque and Power at 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure - bar (psi)
250
(3600)
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Outlet Pressure - bar (psi)
Delivery and Efficiency at 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
200 (53)
150 (40)
100 (26)
50 (13)
0
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
Delivery -l/min (USgpm)
Input Torque - Nm (in.lb.)
Efficiency - %
Input Power - kW (hp)
Performance
Industrial
PVM098
72
70
68
66
64
62
60
58
56
54
52
78
76
74
72
70
68
66
64
62
60
58
56
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
Outlet Pressure – bar (psi)
Noise Level – dBA
Sound pressure data
equivalent to NFPA)
Typical Noise Levels at 1800 and 1200 r/min
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
1200 r/min
Min. Flow
1200 r/min
Max. Flow
1800 r/min
Min. Flow
1800 r/min
Max. Flow
Noise Level – dBA
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
Outlet Pressure – bar (psi)
Typical Noise Levels at 1500 and 1000 r/min
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
1500 r/min
Max. Flow
1000 r/min
Min. Flow
1500 r/min
Min. Flow
1000 r/min
Max. Flow
72
70
68
66
64
62
60
58
56
54
52
78
76
74
72
70
68
66
64
62
60
58
56
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
Outlet Pressure – bar (psi)
Noise Level – dBA
Sound pressure data
equivalent to NFPA)
Typical Noise Levels at 1800 and 1200 r/min
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
1200 r/min
Min. Flow
1200 r/min
Max. Flow
1800 r/min
Min. Flow
1800 r/min
Max. Flow
Noise Level – dBA
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
Outlet Pressure – bar (psi)
Typical Noise Levels at 1500 and 1000 r/min
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
1500 r/min
Max. Flow
1000 r/min
Min. Flow
1500 r/min
Min. Flow
1000 r/min
Max. Flow
57EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
100 (134)
75 (101)
50 (67)
25 (34)
0
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Input Torque and Power at 1200 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
200 (53)
150 (40)
100 (26)
50 (13)
0
550 (4867)
500 (4425)
450 (3982)
400 (3540)
350 (3097)
300 (2655)
250 (2212)
200 (1770)
150 (1327)
100 (885)
50 (442)
0
100 (134)
75 (101)
50 (67)
25 (34)
0
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Input Torque and Power at 1200 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
200 (53)
150 (40)
100 (26)
50 (13)
0
550 (4867)
500 (4425)
450 (3982)
400 (3540)
350 (3097)
300 (2655)
250 (2212)
200 (1770)
150 (1327)
100 (885)
50 (442)
0
Performance
Industrial
PVM098
550 (4867)
500 (4425)
450 (3982)
400 (3540)
350 (3097)
300 (2655)
250 (2212)
200 (1770)
150 (1327)
100 (885)
50 (442)
0
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Input Torque and Power at 1500 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
100 (134)
75 (101)
50 (67)
25 (34)
0
200 (53)
150 (40)
100 (26)
50 (13)
0
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1500 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
550 (4867)
500 (4425)
450 (3982)
400 (3540)
350 (3097)
300 (2655)
250 (2212)
200 (1770)
150 (1327)
100 (885)
50 (442)
0
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Input Torque and Power at 1500 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
100 (134)
75 (101)
50 (67)
25 (34)
0
200 (53)
150 (40)
100 (26)
50 (13)
0
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1500 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
58 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
5,5 (1.45)
5,0 (1.32)
4,5 (1.19)
4,0 (1.06)
3,5 (0.92)
3,0 (0.79)
2,5 (0.66)
2,0 (0.53)
1,5 (0.40)
1,0 (0.26)
0,5 (0.13)
0
25 (6.60)
24 (6.34)
23 (6.08)
22 (5.81)
21 (5.55)
20 (5.28)
19 (5.02)
18 (4.76)
17 (4.49)
Case Flow Versus Outlet Pressure at Full Flow, 1800 r/min
50°C (120° F) and 1.0 bar absolute (0 psi gauge) Inlet
Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min
50°C (120° F) and 1.0 bar absolute (0 psi gauge) Inlet
0
100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure - bar (psi)
Case Flow - l/min (USgpm)
Case Flow - l/min (USgpm)
250
(3600)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure - bar (psi)
250
(3600)
5,5 (1.45)
5,0 (1.32)
4,5 (1.19)
4,0 (1.06)
3,5 (0.92)
3,0 (0.79)
2,5 (0.66)
2,0 (0.53)
1,5 (0.40)
1,0 (0.26)
0,5 (0.13)
0
25 (6.60)
24 (6.34)
23 (6.08)
22 (5.81)
21 (5.55)
20 (5.28)
19 (5.02)
18 (4.76)
17 (4.49)
Case Flow Versus Outlet Pressure at Full Flow, 1800 r/min
50°C (120° F) and 1.0 bar absolute (0 psi gauge) Inlet
Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min
50°C (120° F) and 1.0 bar absolute (0 psi gauge) Inlet
0
100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure - bar (psi)
Case Flow - l/min (USgpm)
Case Flow - l/min (USgpm)
250
(3600)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure - bar (psi)
250
(3600)
Performance
Industrial
PVM098
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Input Torque and Power at 1000 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0
100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure - bar (psi)
250
(3600)
100 (134)
75 (101)
50 (67)
25 (34)
0
100
90
80
70
60
50
40
30
20
10
0
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1000 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
200 (53)
150 (40)
100 (26)
50 (13)
0
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
550 (4867)
500 (4425)
450 (3982)
400 (3540)
350 (3097)
300 (2655)
250 (2212)
200 (1770)
150 (1327)
100 (885)
50 (442)
0
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Input Torque and Power at 1000 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0
100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure - bar (psi)
250
(3600)
100 (134)
75 (101)
50 (67)
25 (34)
0
100
90
80
70
60
50
40
30
20
10
0
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1000 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
200 (53)
150 (40)
100 (26)
50 (13)
0
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
550 (4867)
500 (4425)
450 (3982)
400 (3540)
350 (3097)
300 (2655)
250 (2212)
200 (1770)
150 (1327)
100 (885)
50 (442)
0
59EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Delivery and Case Flow Versus Speed
@ 93°C (200°F), full flow and
1.0 bar absolute (0 psi) gauge Inlet
220 (58)
200 (53)
180 (48)
160 (42)
140 (37)
120 (32)
100 (26)
80 (21)
60 (16)
40 (11)
20 (5)
0
0 500 1000 1500 2000 2500
2 (0.5)
4 (1.1)
6 (1.6)
8 (2.1)
Speed – r/min
Case Flow – l/min (USgpm)
50 bar (700 psi),
Delivery
280 bar (4000 psi),
Delivery
280 bar (4000 psi),
Case flow
50 bar (700 psi),
Case flow
Delivery – l/min (USgpm)
0
600 (5310)
540 (4779)
420 (3717)
300 (2655)
240 (2124)
180 (1593)
120 (1062)
60 (531)
0
480 (4248)
360 (3186)
Input Torque – Nm (in.lb.)
500 1000 1500 2000 2500 3000
Input Torque Versus Speed
@ 93°C (200°F), full flow and
1.0 bar absolute (0 psi gauge) inlet
Speed – r/min
17 bar (250 psi)
50 bar (700 psi)
100 bar (1500 psi)
250 bar (3600 psi)
150 bar (2200 psi)
200 bar (2900 psi)
280 bar (4000 psi)
320 bar (4600 psi)
Performance
Mobile
PVM098
100 bar (1500 psi)
150 bar (2200 psi)
200 bar (2900 psi)
250 bar (3600 psi)
280 bar (4000 psi)
320 bar (4600 psi)
70
75
80
85
90
95
0
500
1000 1500 2000 2500
Speed – r/min
Overall Efficiency (%)
50 bar (700 psi)
Overall Efficiency Versus Speed
@ 93°C (200°F) and 1.0 bar absolute
(0 psi gauge) inlet
Outlet Pressure – bar (psi)
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
0
64
66
68
70
72
74
76
78
80
82
84
86
Noise Level – dBA
600 r/min
Max. flow
600 r/min
Min. flow
2000 r/min
Max. flow
2000 r/min
Min. flow
Sound pressure
data equivalent to NFP
Typical Noise Levels at 2000 and 600 r/min
with petroleum oil (10 W) @ 93°C (200°F)
and 1.0 bar absolute (0 psi gauge) inlet
100 bar (1500 psi)
150 bar (2200 psi)
200 bar (2900 psi)
250 bar (3600 psi)
280 bar (4000 psi)
320 bar (4600 psi)
70
75
80
85
90
95
0
500
1000 1500 2000 2500
Speed – r/min
Overall Efficiency (%)
50 bar (700 psi)
Overall Efficiency Versus Speed
@ 93°C (200°F) and 1.0 bar absolute
(0 psi gauge) inlet
Outlet Pressure – bar (psi)
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
0
64
66
68
70
72
74
76
78
80
82
84
86
Noise Level – dBA
600 r/min
Max. flow
600 r/min
Min. flow
2000 r/min
Max. flow
2000 r/min
Min. flow
Sound pressure
data equivalent to NFP
Typical Noise Levels at 2000 and 600 r/min
with petroleum oil (10 W) @ 93°C (200°F)
and 1.0 bar absolute (0 psi gauge) inlet
Delivery and Case Flow Versus Speed
@ 93°C (200°F), full flow and
1.0 bar absolute (0 psi) gauge Inlet
220 (58)
200 (53)
180 (48)
160 (42)
140 (37)
120 (32)
100 (26)
80 (21)
60 (16)
40 (11)
20 (5)
0
0 500 1000 1500 2000 2500
2 (0.5)
4 (1.1)
6 (1.6)
8 (2.1)
Speed – r/min
Case Flow – l/min (USgpm)
50 bar (700 psi),
Delivery
280 bar (4000 psi),
Delivery
280 bar (4000 psi),
Case flow
50 bar (700 psi),
Case flow
Delivery – l/min (USgpm)
0
600 (5310)
540 (4779)
420 (3717)
300 (2655)
240 (2124)
180 (1593)
120 (1062)
60 (531)
0
480 (4248)
360 (3186)
Input Torque – Nm (in.lb.)
500 1000 1500 2000 2500 3000
Input Torque Versus Speed
@ 93°C (200°F), full flow and
1.0 bar absolute (0 psi gauge) inlet
Speed – r/min
17 bar (250 psi)
50 bar (700 psi)
100 bar (1500 psi)
250 bar (3600 psi)
150 bar (2200 psi)
200 bar (2900 psi)
280 bar (4000 psi)
320 bar (4600 psi)
60 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Case Flow at 2200 r/min, Full Flow
93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet
16 (4.2)
14 (3.7)
12 (3.2)
10 (2.6)
8 (2.1)
6 (1.6)
4 (1.0)
2 (0.5)
0
Case Flow – l/min (USgpm)
0
100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
240 (2124)
220 (1947)
200 (1770)
180 (1593)
160 (1416)
140 (1239)
120 (1062)
100 (885)
80 (708)
60 (531)
40 (354)
20 (177)
0 500 1000 1500 2000 2500
5 (1.3)
10 (2.6)
15 (4.0)
20 (5.3)
25 (6.6)
30 (7.9)
Case Flow – l/min (USgpm)
Input Torque – Nm (lb.in.)
Speed – r/min
280 bar (4000 psi)
Input Torque
150 bar (2200 psi)
Input Torque
280 bar (4000 psi)
Case Flow
150 bar (2200 psi), Case Flow
Input Torque and Case Flow Versus Speed
@ 93°C (200°F), cut-off and
1.0 bar absolute (0 psi gauge) inlet
32 (8.4)
28 (7.4)
24 (6.3)
20 (5.3)
16 (4.2)
12 (3.2)
Case Flow at 2200 r/min, Minimum Flow
935C (2005F), 1.0 bar absolute (0 psi gauge) Inlet
Case Flow – l/min (USgpm)
0
100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
Performance
Mobile
PVM098
20 bar (300) differential
Input Torque
11 bar (160) differential
Input Torque
11 bar (160) differential
Case Flow
20 bar (300) differential
Case Flow
Speed – r/min
Input Torque – Nm (in.lb.)
Case Flow (l/min (USgpm)
7.0 (1.85)
6.5 (1.72)
6.0 (1.59)
5.5 (1.45)
10 (88)
8 (71)
6 (53)
4 (35)
2 (18)
0 500 1000 1500 2000 2500
9.0 (2.38)
8.5 (2.25)
8.0 (2.11)
7.5 (1.98)
1 (9)
3 (27)
5 (44)
7 (62)
9 (80)
11 (77)
Input Torque and Case Flow Versus Speed
@ 93°C (200°F), load sense standby
and 1.0 bar absolute (0 psi gauge) inlet
17 bar (250 psi)
50 bar (700 psi)
100 bar (1500 psi)
250 bar (3600 psi)
150 bar (2200 psi)
200 bar (2900 psi)
280 bar (4000 psi)
320 bar (4600 psi)
Speed – r/min
500 1000 1500 2000 2500
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
60 (80)
70 (94)
80 (107)
90 (121)
100 (134)
110 (148)
120 (161)
130 (174)
Input Power – KW (hp)
0
3000
Input Power Versus Speed
@93°C (200°F), full flow and
1.0 bar absolute (0 psi gauge) inlet
20 bar (300) differential
Input Torque
11 bar (160) differential
Input Torque
11 bar (160) differential
Case Flow
20 bar (300) differential
Case Flow
Speed – r/min
Input Torque – Nm (in.lb.)
Case Flow (l/min (USgpm)
7.0 (1.85)
6.5 (1.72)
6.0 (1.59)
5.5 (1.45)
10 (88)
8 (71)
6 (53)
4 (35)
2 (18)
0 500 1000 1500 2000 2500
9.0 (2.38)
8.5 (2.25)
8.0 (2.11)
7.5 (1.98)
1 (9)
3 (27)
5 (44)
7 (62)
9 (80)
11 (77)
Input Torque and Case Flow Versus Speed
@ 93°C (200°F), load sense standby
and 1.0 bar absolute (0 psi gauge) inlet
17 bar (250 psi)
50 bar (700 psi)
100 bar (1500 psi)
250 bar (3600 psi)
150 bar (2200 psi)
200 bar (2900 psi)
280 bar (4000 psi)
320 bar (4600 psi)
Speed – r/min
500 1000 1500 2000 2500
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
60 (80)
70 (94)
80 (107)
90 (121)
100 (134)
110 (148)
120 (161)
130 (174)
Input Power – KW (hp)
0
3000
Input Power Versus Speed
@93°C (200°F), full flow and
1.0 bar absolute (0 psi gauge) inlet
61EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency - %
Outlet Pressure - bar (psi)
Delivery and Efficiency at 1800 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (13)
100 (26)
0
10
20
30
40
50
60
70
80
90
100
150 (40)
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
200 (53)
250 (66)
Delivery and Efficiency at 1500 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
Delivery – l/min (USgpm)
0
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
Overall Efficiency
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure - bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1800 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Input Torque,
Cut-off
400 (3540)
450 (3982)
500 (4425)
100 (134)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1500 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,
Full Stroke
Input Torque,
Full Stroke
400 (3540)
450 (3982)
500 (4425)
100 (134)
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency - %
Outlet Pressure - bar (psi)
Delivery and Efficiency at 1800 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (13)
100 (26)
0
10
20
30
40
50
60
70
80
90
100
150 (40)
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
200 (53)
250 (66)
Delivery and Efficiency at 1500 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
Delivery – l/min (USgpm)
0
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
Overall Efficiency
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure - bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1800 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Input Torque,
Cut-off
400 (3540)
450 (3982)
500 (4425)
100 (134)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1500 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,
Full Stroke
Input Torque,
Full Stroke
400 (3540)
450 (3982)
500 (4425)
100 (134)
Performance
Industrial
PVM106
Noise Level – dBA
Typical Noise Levels at 1800 and 1200 r/min.
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
62
64
68
70
72
1200 r/min
min. flow
74
76
78
1200 r/min
max. flow
80
66
1800 r/min
max. flow
1800 r/min
min. flow
Typical Noise Levels at 1500 and 1000 r/min.
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
Noise Level – dBA
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
Sound pressure data
equivalent to NFPA.
58
60
62
64
66
68
70
72
1000 r/min
min. flow
1500 r/min
min. flow
74
76
1000 r/min
max. flow
1500 r/min
max. flow
Noise Level – dBA
Typical Noise Levels at 1800 and 1200 r/min.
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
62
64
68
70
72
1200 r/min
min. flow
74
76
78
1200 r/min
max. flow
80
66
1800 r/min
max. flow
1800 r/min
min. flow
Typical Noise Levels at 1500 and 1000 r/min.
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
Noise Level – dBA
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
Sound pressure data
equivalent to NFPA.
58
60
62
64
66
68
70
72
1000 r/min
min. flow
1500 r/min
min. flow
74
76
1000 r/min
max. flow
1500 r/min
max. flow
62 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance
Industrial
PVM106
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency - %
Outlet Pressure - bar (psi)
Delivery and Efficiency at 1800 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (13)
100 (26)
0
10
20
30
40
50
60
70
80
90
100
150 (40)
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
200 (53)
250 (66)
Delivery and Efficiency at 1500 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
Delivery – l/min (USgpm)
0
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
Overall Efficiency
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure - bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1800 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Input Torque,
Cut-off
400 (3540)
450 (3982)
500 (4425)
100 (134)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1500 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,
Full Stroke
Input Torque,
Full Stroke
400 (3540)
450 (3982)
500 (4425)
100 (134)
0
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency - %
Outlet Pressure - bar (psi)
Delivery and Efficiency at 1800 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (13)
100 (26)
0
10
20
30
40
50
60
70
80
90
100
150 (40)
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
200 (53)
250 (66)
Delivery and Efficiency at 1500 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
Delivery – l/min (USgpm)
0
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
Overall Efficiency
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure - bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1800 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Input Torque,
Cut-off
400 (3540)
450 (3982)
500 (4425)
100 (134)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1500 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,
Full Stroke
Input Torque,
Full Stroke
400 (3540)
450 (3982)
500 (4425)
100 (134)
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
Delivery and Efficiency at 1000 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
0
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1200 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Torque,
Full Stroke
400 (3540)
450 (3982)
500 (4425)
100 (134)
Input Power,
Full Stroke
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1000 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
100 (134)
Input Power,
Full Stroke
Input To rque,
Full Stroke
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
Delivery and Efficiency at 1000 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
0
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1200 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Torque,
Full Stroke
400 (3540)
450 (3982)
500 (4425)
100 (134)
Input Power,
Full Stroke
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1000 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
100 (134)
Input Power,
Full Stroke
Input To rque,
Full Stroke
63EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Case Flow l/min – (USgpm)
Outlet Pressure – bar (psi)
Case Flow versus Outlet Pressure at 1800 r/min, Full Flow,
50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
0.5 (0.13)
1.0 (0.26)
1.5 (0.4)
2.0 (0.53)
2.5 (0.66)
3.0 (0.79)
3.5 (0.92)
4.0 (1.06)
Case Flow versus Outlet Pressure at Cutoff, 1800 r/min,
50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Case Flow l/min – (USgpm)
Outlet Pressure – bar (psi)
0
11 (2.91)
12 (3.17)
14 (3.70)
15 (3.96)
17 (4.49)
18 (4.76)
13 (3.43)
16 (4.23)
19 (5.02)
20 (5.28)
21 (5.55)
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Case Flow l/min – (USgpm)
Outlet Pressure – bar (psi)
Case Flow versus Outlet Pressure at 1800 r/min, Full Flow,
50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
0.5 (0.13)
1.0 (0.26)
1.5 (0.4)
2.0 (0.53)
2.5 (0.66)
3.0 (0.79)
3.5 (0.92)
4.0 (1.06)
Case Flow versus Outlet Pressure at Cutoff, 1800 r/min,
50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Case Flow l/min – (USgpm)
Outlet Pressure – bar (psi)
0
11 (2.91)
12 (3.17)
14 (3.70)
15 (3.96)
17 (4.49)
18 (4.76)
13 (3.43)
16 (4.23)
19 (5.02)
20 (5.28)
21 (5.55)
Performance
Industrial
PVM106
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
Delivery and Efficiency at 1000 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
0
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1200 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Torque,
Full Stroke
400 (3540)
450 (3982)
500 (4425)
100 (134)
Input Power,
Full Stroke
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1000 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
100 (134)
Input Power,
Full Stroke
Input To rque,
Full Stroke
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
Delivery and Efficiency at 1000 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery – l/min (USgpm)
0
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1200 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Torque,
Full Stroke
400 (3540)
450 (3982)
500 (4425)
100 (134)
Input Power,
Full Stroke
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1000 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
100 (134)
Input Power,
Full Stroke
Input To rque,
Full Stroke
64 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance
Mobile
PVM106
Sound pressure data
equivalent to NFPA.
Noise Level – dBA
Typical Noise Levels at 2200 & 600 r/min
with Petroleum Oil (10W) at 93°C (200°F)
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
54
58
62
66
70
74
78
2200 r/min
min. flow
600 r/min
max. flow
Outlet Pressure – bar (psi)
82
Overall Efficiency (%)
Overall Efficiency versus Speed at
93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet
0 500 1000 1500 2000 2500
Speed – r/min
50
75
85
95
55
70
80
90
65
100
3000
50 bar (725 psi)
100 bar
(1450 psi)
150 bar
(2200 psi)
60
230 bar (3300 psi)
200 bar
(2900 psi)
210 bar
(3000 psi)
Delivery and Case Flow versus Speed at 93°C (200°F),
Full Flow 1.0 bar absolute (0 psi gauge) Inlet
0
Speed (r/min)
Delivery – l/min (USgpm)
40 (11)
60 (16)
80 (21)
100 (26)
120 (32)
500 1000 1500 2000 2500
140 (37)
20 (5)
4 (1.06)
2 (0.53)
0
50 bar (725
psi) Delivery
50 bar (725 psi) Case Flow
160 (42)
6 (1.59)
8 (2.11)
210 bar (3000
psi) Delivery
200 (53)
180 (48)
Case Flow
l/min
(USgpm)
210 bar (3000 psi) Case Flow
240 (63)
220 (58)
10 (2.6)
86
600 r/min
min. flow
2200 r/min
max. flow
Sound pressure data
equivalent to NFPA.
Noise Level – dBA
Typical Noise Levels at 2200 & 600 r/min
with Petroleum Oil (10W) at 93°C (200°F)
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
54
58
62
66
70
74
78
2200 r/min
min. flow
600 r/min
max. flow
Outlet Pressure – bar (psi)
82
Overall Efficiency (%)
Overall Efficiency versus Speed at
93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet
0 500 1000 1500 2000 2500
Speed – r/min
50
75
85
95
55
70
80
90
65
100
3000
50 bar (725 psi)
100 bar
(1450 psi)
150 bar
(2200 psi)
60
230 bar (3300 psi)
200 bar
(2900 psi)
210 bar
(3000 psi)
Delivery and Case Flow versus Speed at 93°C (200°F),
Full Flow 1.0 bar absolute (0 psi gauge) Inlet
0
Speed (r/min)
Delivery – l/min (USgpm)
40 (11)
60 (16)
80 (21)
100 (26)
120 (32)
500 1000 1500 2000 2500
140 (37)
20 (5)
4 (1.06)
2 (0.53)
0
50 bar (725
psi) Delivery
50 bar (725 psi) Case Flow
160 (42)
6 (1.59)
8 (2.11)
210 bar (3000
psi) Delivery
200 (53)
180 (48)
Case Flow
l/min
(USgpm)
210 bar (3000 psi) Case Flow
240 (63)
220 (58)
10 (2.6)
86
600 r/min
min. flow
2200 r/min
max. flow
Sound pressure data
equivalent to NFPA.
Noise Level – dBA
Typical Noise Levels at 2200 & 600 r/min
with Petroleum Oil (10W) at 93°C (200°F)
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
54
58
62
66
70
74
78
2200 r/min
min. flow
600 r/min
max. flow
Outlet Pressure – bar (psi)
82
Overall Efficiency (%)
Overall Efficiency versus Speed at
93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet
0 500 1000 1500 2000 2500
Speed – r/min
50
75
85
95
55
70
80
90
65
100
3000
50 bar (725 psi)
100 bar
(1450 psi)
150 bar
(2200 psi)
60
230 bar (3300 psi)
200 bar
(2900 psi)
210 bar
(3000 psi)
Delivery and Case Flow versus Speed at 93°C (200°F),
Full Flow 1.0 bar absolute (0 psi gauge) Inlet
0
Speed (r/min)
Delivery – l/min (USgpm)
40 (11)
60 (16)
80 (21)
100 (26)
120 (32)
500 1000 1500 2000 2500
140 (37)
20 (5)
4 (1.06)
2 (0.53)
0
50 bar (725
psi) Delivery
50 bar (725 psi) Case Flow
160 (42)
6 (1.59)
8 (2.11)
210 bar (3000
psi) Delivery
200 (53)
180 (48)
Case Flow
l/min
(USgpm)
210 bar (3000 psi) Case Flow
240 (63)
220 (58)
10 (2.6)
86
600 r/min
min. flow
2200 r/min
max. flow
65EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance
Mobile
PVM106
0 1000500 20001500
Speed (r/min)
2500
Input Torque – Nm (in.lb.)
Input Torque versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
3000
210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
17 bar (250 psi)
50 bar (725 psi)
350 (3097)
230 bar (3300 psi)
400 (3540)
450 (3982)
200 bar (2900 psi)
01000500 20001500
Speed (r/min)
2500
Input Power – kW (hp)
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
90 (121)
Input Power versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
60 (80)
70 (94)
80 (107)
100 (134)
210 bar (3000 psi)
230 bar (3300 psi)
150 bar (2200 psi)
100 bar (1500 psi)
50 bar (725 psi)
17 bar (250 psi)
Input Torque and Case Flow versus Speed at 93°C
(200°F), Load Sense Standby and 1.0 bar absolute
(0 psi gauge) Inlet
0
Speed (r/min)
Input Torque – Nm (in.lb.)
2 (18)
3 (27)
4 (35)
5 (44)
6 (53)
500 1000 1500 2000 2500
1 (9)
6.5 (1.72)
7.0 (1.85)
7 (62)
8 (71)
7.5 (1.98)
8.0 (2.11)
20 bar (300 psi)
diff. Case Flow
9 (80)
6.0 (1.59)
Case
Flow l/min
(USgpm)
12 (106)
10 (88)
11 (97)
8.5 (2.25)
9.0 (2.38)
20 bar (300 psi)
diff. Input Torque
11 bar (160 psi) diff.
Input Torque
11 bar (160 psi) diff.
Case Flow
0
Input Torque and Case Flow versus Speed at 93°C
(200°F), Pressure Limit Cut-off and 1.0 bar absolute
(0 psi gauge) Inlet
10 (88)
20 (177)
30 (265)
40 (354)
500 1000 1500 2000 2500
(Input Torque – Nm (in.lb.)
50 (442)
60 (531)
210 bar (3000 psi) Input Torque
Speed (r/min)
5 (1.3)
150 bar (2200 psi)
Case Flow
70 (619)
80 (708)
10 (2.6)
15 (4.0)
30 (7.9)
150 bar (2200 psi)
Input Torque
Case
Flow l/min
(USgpm)
90 (796)
100 (885)
110 (973)
120 (1062)
130 (1150)
140 (1239)
210 bar (3000 psi) Case Flow
25 (6.6)
20 (5.3)
0 1000500 20001500
Speed (r/min)
2500
Input Torque – Nm (in.lb.)
Input Torque versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
3000
210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
17 bar (250 psi)
50 bar (725 psi)
350 (3097)
230 bar (3300 psi)
400 (3540)
450 (3982)
200 bar (2900 psi)
01000500 20001500
Speed (r/min)
2500
Input Power – kW (hp)
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
90 (121)
Input Power versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
60 (80)
70 (94)
80 (107)
100 (134)
210 bar (3000 psi)
230 bar (3300 psi)
150 bar (2200 psi)
100 bar (1500 psi)
50 bar (725 psi)
17 bar (250 psi)
Input Torque and Case Flow versus Speed at 93°C
(200°F), Load Sense Standby and 1.0 bar absolute
(0 psi gauge) Inlet
0
Speed (r/min)
Input Torque – Nm (in.lb.)
2 (18)
3 (27)
4 (35)
5 (44)
6 (53)
500 1000 1500 2000 2500
1 (9)
6.5 (1.72)
7.0 (1.85)
7 (62)
8 (71)
7.5 (1.98)
8.0 (2.11)
20 bar (300 psi)
diff. Case Flow
9 (80)
6.0 (1.59)
Case
Flow l/min
(USgpm)
12 (106)
10 (88)
11 (97)
8.5 (2.25)
9.0 (2.38)
20 bar (300 psi)
diff. Input Torque
11 bar (160 psi) diff.
Input Torque
11 bar (160 psi) diff.
Case Flow
0
Input Torque and Case Flow versus Speed at 93°C
(200°F), Pressure Limit Cut-off and 1.0 bar absolute
(0 psi gauge) Inlet
10 (88)
20 (177)
30 (265)
40 (354)
500 1000 1500 2000 2500
(Input Torque – Nm (in.lb.)
50 (442)
60 (531)
210 bar (3000 psi) Input Torque
Speed (r/min)
5 (1.3)
150 bar (2200 psi)
Case Flow
70 (619)
80 (708)
10 (2.6)
15 (4.0)
30 (7.9)
150 bar (2200 psi)
Input Torque
Case
Flow l/min
(USgpm)
90 (796)
100 (885)
110 (973)
120 (1062)
130 (1150)
140 (1239)
210 bar (3000 psi) Case Flow
25 (6.6)
20 (5.3)
0 1000500 20001500
Speed (r/min)
2500
Input Torque – Nm (in.lb.)
Input Torque versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
3000
210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
17 bar (250 psi)
50 bar (725 psi)
350 (3097)
230 bar (3300 psi)
400 (3540)
450 (3982)
200 bar (2900 psi)
01000500 20001500
Speed (r/min)
2500
Input Power – kW (hp)
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
90 (121)
Input Power versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
60 (80)
70 (94)
80 (107)
100 (134)
210 bar (3000 psi)
230 bar (3300 psi)
150 bar (2200 psi)
100 bar (1500 psi)
50 bar (725 psi)
17 bar (250 psi)
Input Torque and Case Flow versus Speed at 93°C
(200°F), Load Sense Standby and 1.0 bar absolute
(0 psi gauge) Inlet
0
Speed (r/min)
Input Torque – Nm (in.lb.)
2 (18)
3 (27)
4 (35)
5 (44)
6 (53)
500 1000 1500 2000 2500
1 (9)
6.5 (1.72)
7.0 (1.85)
7 (62)
8 (71)
7.5 (1.98)
8.0 (2.11)
20 bar (300 psi)
diff. Case Flow
9 (80)
6.0 (1.59)
Case
Flow l/min
(USgpm)
12 (106)
10 (88)
11 (97)
8.5 (2.25)
9.0 (2.38)
20 bar (300 psi)
diff. Input Torque
11 bar (160 psi) diff.
Input Torque
11 bar (160 psi) diff.
Case Flow
0
Input Torque and Case Flow versus Speed at 93°C
(200°F), Pressure Limit Cut-off and 1.0 bar absolute
(0 psi gauge) Inlet
10 (88)
20 (177)
30 (265)
40 (354)
500 1000 1500 2000 2500
(Input Torque – Nm (in.lb.)
50 (442)
60 (531)
210 bar (3000 psi) Input Torque
Speed (r/min)
5 (1.3)
150 bar (2200 psi)
Case Flow
70 (619)
80 (708)
10 (2.6)
15 (4.0)
30 (7.9)
150 bar (2200 psi)
Input Torque
Case
Flow l/min
(USgpm)
90 (796)
100 (885)
110 (973)
120 (1062)
130 (1150)
140 (1239)
210 bar (3000 psi) Case Flow
25 (6.6)
20 (5.3)
0 1000500 20001500
Speed (r/min)
2500
Input Torque – Nm (in.lb.)
Input Torque versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
3000
210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
17 bar (250 psi)
50 bar (725 psi)
350 (3097)
230 bar (3300 psi)
400 (3540)
450 (3982)
200 bar (2900 psi)
01000500 20001500
Speed (r/min)
2500
Input Power – kW (hp)
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
90 (121)
Input Power versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
60 (80)
70 (94)
80 (107)
100 (134)
210 bar (3000 psi)
230 bar (3300 psi)
150 bar (2200 psi)
100 bar (1500 psi)
50 bar (725 psi)
17 bar (250 psi)
Input Torque and Case Flow versus Speed at 93°C
(200°F), Load Sense Standby and 1.0 bar absolute
(0 psi gauge) Inlet
0
Speed (r/min)
Input Torque – Nm (in.lb.)
2 (18)
3 (27)
4 (35)
5 (44)
6 (53)
500 1000 1500 2000 2500
1 (9)
6.5 (1.72)
7.0 (1.85)
7 (62)
8 (71)
7.5 (1.98)
8.0 (2.11)
20 bar (300 psi)
diff. Case Flow
9 (80)
6.0 (1.59)
Case
Flow l/min
(USgpm)
12 (106)
10 (88)
11 (97)
8.5 (2.25)
9.0 (2.38)
20 bar (300 psi)
diff. Input Torque
11 bar (160 psi) diff.
Input Torque
11 bar (160 psi) diff.
Case Flow
0
Input Torque and Case Flow versus Speed at 93°C
(200°F), Pressure Limit Cut-off and 1.0 bar absolute
(0 psi gauge) Inlet
10 (88)
20 (177)
30 (265)
40 (354)
500 1000 1500 2000 2500
(Input Torque – Nm (in.lb.)
50 (442)
60 (531)
210 bar (3000 psi) Input Torque
Speed (r/min)
5 (1.3)
150 bar (2200 psi)
Case Flow
70 (619)
80 (708)
10 (2.6)
15 (4.0)
30 (7.9)
150 bar (2200 psi)
Input Torque
Case
Flow l/min
(USgpm)
90 (796)
100 (885)
110 (973)
120 (1062)
130 (1150)
140 (1239)
210 bar (3000 psi) Case Flow
25 (6.6)
20 (5.3)
66 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
720 (6372)
660 (5841)
600 (5310)
540 (4779)
480 (4248)
420 (3717)
360 (3186)
300 (2655)
240 (2124)
180 (1593)
120 (1062)
60 (531)
0
Input Torque – Nm (in.lb.)
140 (188)
120 (161)
100 (134)
80 (107)
60 (81)
40 (54)
20 (27)
0
Input Power – kW (hp)
Input Torque
Input Power,
Full Stroke
Input Torque,
Cut-off
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque and Power at 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
240 (63)
200 (53)
160 (42)
120 (32)
80 (21)
40 (11)
0
Delivery – l/min (USgpm)
Volumetric
Efficiency
Overall Efficiency
Delivery (effective flow)
720 (6372)
660 (5841)
600 (5310)
540 (4779)
480 (4248)
420 (3717)
360 (3186)
300 (2655)
240 (2124)
180 (1593)
120 (1062)
60 (531)
0
Input Torque – Nm (in.lb.)
140 (188)
120 (161)
100 (134)
80 (107)
60 (81)
40 (54)
20 (27)
0
Input Power – kW (hp)
Input Torque
Input Power,
Full Stroke
Input Torque,
Cut-off
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque and Power at 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
240 (63)
200 (53)
160 (42)
120 (32)
80 (21)
40 (11)
0
Delivery – l/min (USgpm)
Volumetric
Efficiency
Overall Efficiency
Delivery (effective flow)
Performance
Industrial
PVM131
Typical Noise Levels at 1500 and 1000 r/min
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
76
74
72
70
68
66
64
62
60
58
56
Noise Level – dBA
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
Outlet Pressure – bar (psi)
1500 r/min
Max. Flow
1500 r/min
Min. Flow
1000 r/min
Max. Flow
1000 r/min
Min. Flow
82
80
78
76
74
72
70
68
66
64
62
60
Noise Level – dBA
Typical Noise Levels at 1800 and 1200 r/min
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
Sound pressure data
equivalent to NFPA
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
Outlet Pressure – bar (psi)
1800 r/min
Max. Flow
1800 r/min
Min. Flow
1200 r/min
Max. Flow
1200 r/min
Min. Flow
Typical Noise Levels at 1500 and 1000 r/min
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
76
74
72
70
68
66
64
62
60
58
56
Noise Level – dBA
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
Outlet Pressure – bar (psi)
1500 r/min
Max. Flow
1500 r/min
Min. Flow
1000 r/min
Max. Flow
1000 r/min
Min. Flow
82
80
78
76
74
72
70
68
66
64
62
60
Noise Level – dBA
Typical Noise Levels at 1800 and 1200 r/min
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
Sound pressure data
equivalent to NFPA
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
Outlet Pressure – bar (psi)
1800 r/min
Max. Flow
1800 r/min
Min. Flow
1200 r/min
Max. Flow
1200 r/min
Min. Flow
67EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
100 (134)
80 (107)
60 (81)
40 (54)
20 (27)
0
240 (63)
200 (53)
160 (42)
120 (32)
80 (21)
40 (11)
0
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric
Efficiency
Overall Efficiency
Delivery (effective flow)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque
Input Power,
Full Stroke
Input Torque and Power at 1200 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
660 (5841)
600 (5310)
540 (4779)
480 (4248)
420 (3717)
360 (3186)
300 (2655)
240 (2124)
180 (1593)
120 (1062)
60 (531)
0
100 (134)
80 (107)
60 (81)
40 (54)
20 (27)
0
240 (63)
200 (53)
160 (42)
120 (32)
80 (21)
40 (11)
0
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric
Efficiency
Overall Efficiency
Delivery (effective flow)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque
Input Power,
Full Stroke
Input Torque and Power at 1200 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
660 (5841)
600 (5310)
540 (4779)
480 (4248)
420 (3717)
360 (3186)
300 (2655)
240 (2124)
180 (1593)
120 (1062)
60 (531)
0
Performance
Industrial
PVM131
240 (63)
200 (53)
160 (42)
120 (32)
80 (21)
40 (11)
0
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1500 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric
Efficiency
Overall Efficiency
Delivery (effective flow)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque
Input Power,
Full Stroke
Input Torque and Power at 1500 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
120 (161)
100 (134)
80 (107)
60 (81)
40 (54)
20 (27)
0
720 (6372)
660 (5841)
600 (5310)
540 (4779)
480 (4248)
420 (3717)
360 (3186)
300 (2655)
240 (2124)
180 (1593)
120 (1062)
60 (531)
0
240 (63)
200 (53)
160 (42)
120 (32)
80 (21)
40 (11)
0
100
90
80
70
60
50
40
30
20
10
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1500 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric
Efficiency
Overall Efficiency
Delivery (effective flow)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque
Input Power,
Full Stroke
Input Torque and Power at 1500 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
120 (161)
100 (134)
80 (107)
60 (81)
40 (54)
20 (27)
0
720 (6372)
660 (5841)
600 (5310)
540 (4779)
480 (4248)
420 (3717)
360 (3186)
300 (2655)
240 (2124)
180 (1593)
120 (1062)
60 (531)
0
68 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
8 (2.1)
7 (1.8)
6 (1.6)
5 (1.3)
4 (1.1)
3 (0.8)
2 (0.5)
1 (0.3)
0
Case Flow – l/min (USgpm)
Case Flow Versus Outlet Pressure at Full Flow, 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
24 (6.3)
20 (5.3)
16 (4.2)
12 (3.2)
8 (2.1)
4 (1.1)
0
Case Flow – l/min (USgpm)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
8 (2.1)
7 (1.8)
6 (1.6)
5 (1.3)
4 (1.1)
3 (0.8)
2 (0.5)
1 (0.3)
0
Case Flow – l/min (USgpm)
Case Flow Versus Outlet Pressure at Full Flow, 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
24 (6.3)
20 (5.3)
16 (4.2)
12 (3.2)
8 (2.1)
4 (1.1)
0
Case Flow – l/min (USgpm)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
Performance
Industrial
PVM131
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1000 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric
Efficiency
Overall Efficiency
Delivery (effective flow)
200 (53)
160 (42)
120 (32)
80 (21)
40 (11)
0
100
90
80
70
60
50
40
30
20
10
0
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque
Input Power,
Full Stroke
Input Torque and Power at 1000 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
660 (5841)
600 (5310)
540 (4779)
480 (4248)
420 (3717)
360 (3186)
300 (2655)
240 (2124)
180 (1593)
120 (1062)
60 (531)
0
100 (134)
80 (107)
60 (81)
40 (54)
20 (27)
0
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
350
(5000)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1000 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric
Efficiency
Overall Efficiency
Delivery (effective flow)
200 (53)
160 (42)
120 (32)
80 (21)
40 (11)
0
100
90
80
70
60
50
40
30
20
10
0
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque
Input Power,
Full Stroke
Input Torque and Power at 1000 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
660 (5841)
600 (5310)
540 (4779)
480 (4248)
420 (3717)
360 (3186)
300 (2655)
240 (2124)
180 (1593)
120 (1062)
60 (531)
0
100 (134)
80 (107)
60 (81)
40 (54)
20 (27)
0
69EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Delivery and Case Flow Versus Speed
@ 93°C (200°F), full flow and
1.0 bar absolute (0 psi) gauge Inlet
260 (69)
240 (63)
220 (58)
200 (53)
180 (48)
160 (42)
140 (37)
120 (32)
100 (26)
80 (21)
60 (16)
40 (11)
20 (5)
00
0 500 1000 1500 2000 2500
4 (1.1)
6 (2.1)
12 (3.2)
16 (4.2)
20 (5.3)
Speed – r/min
50 bar (700 psi),
Delivery
280 bar (4000 psi),
Delivery
280 bar (4000 psi),
Case flow
50 bar (700 psi), Case flow
Delivery – l/min (USgpm)
Input Torque – Nm (in.lb.)
Case Flow – l/min (USgpm)
800 (7080)
700 (6195)
600 (5310)
500 (4425)
400 (3540)
300 (2655)
200 (1770)
100 (885)
0
Speed – r/min
0
500 1000 1500 2000 2500
17 bar (250 psi)
50 bar (700 psi)
100 bar (1500 psi)
250 bar (3600 psi)
150 bar (2200 psi)
200 bar (2900 psi)
280 bar (4000 psi)
320 bar (4600 psi)
Input Torque Versus Speed
@ 93°C (200°F), full flow and
1.0 bar absolute (0 psi gauge) inlet
Performance
Mobile
PVM131
Outlet Pressure – bar (psi)
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
0
58
60
62
64
66
68
70
72
74
76
78
80
82
84
Noise Level – dBA
600 r/min
Max. flow
600 r/min
Min. flow
2000 r/min
Max. flow
2000 r/min
Min. flow
Sound pressure data
equivalent to NFPA
Typical Noise Levels at 2000 and 600 r/min
with petroleum oil (10 W) @ 93°C (200°F)
and 1.0 bar absolute (0 psi gauge) inlet
65
70
75
80
85
90
95
Overall Efficiency (%)
Overall Efficiency Versus Speed
@ 93°C (200°F) and 1.0 bar absolute
(0 psi gauge) inlet
0
500
1000 1500 2000 2500
Speed – r/min
100 bar
(1500 psi)
200 bar
(2900 psi)
250 bar
(3600 psi)
280 bar
(4000 psi)
320 bar
(4600 psi)
50 bar (700 psi)
150 bar
(2200 psi)
Outlet Pressure – bar (psi)
50
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
300
(4400)
0
58
60
62
64
66
68
70
72
74
76
78
80
82
84
Noise Level – dBA
600 r/min
Max. flow
600 r/min
Min. flow
2000 r/min
Max. flow
2000 r/min
Min. flow
Sound pressure data
equivalent to NFPA
Typical Noise Levels at 2000 and 600 r/min
with petroleum oil (10 W) @ 93°C (200°F)
and 1.0 bar absolute (0 psi gauge) inlet
65
70
75
80
85
90
95
Overall Efficiency (%)
Overall Efficiency Versus Speed
@ 93°C (200°F) and 1.0 bar absolute
(0 psi gauge) inlet
0
500
1000 1500 2000 2500
Speed – r/min
100 bar
(1500 psi)
200 bar
(2900 psi)
250 bar
(3600 psi)
280 bar
(4000 psi)
320 bar
(4600 psi)
50 bar (700 psi)
150 bar
(2200 psi)
Delivery and Case Flow Versus Speed
@ 93°C (200°F), full flow and
1.0 bar absolute (0 psi) gauge Inlet
260 (69)
240 (63)
220 (58)
200 (53)
180 (48)
160 (42)
140 (37)
120 (32)
100 (26)
80 (21)
60 (16)
40 (11)
20 (5)
00
0 500 1000 1500 2000 2500
4 (1.1)
6 (2.1)
12 (3.2)
16 (4.2)
20 (5.3)
Speed – r/min
50 bar (700 psi),
Delivery
280 bar (4000 psi),
Delivery
280 bar (4000 psi),
Case flow
50 bar (700 psi), Case flow
Delivery – l/min (USgpm)
Input Torque – Nm (in.lb.)
Case Flow – l/min (USgpm)
800 (7080)
700 (6195)
600 (5310)
500 (4425)
400 (3540)
300 (2655)
200 (1770)
100 (885)
0
Speed – r/min
0
500 1000 1500 2000 2500
17 bar (250 psi)
50 bar (700 psi)
100 bar (1500 psi)
250 bar (3600 psi)
150 bar (2200 psi)
200 bar (2900 psi)
280 bar (4000 psi)
320 bar (4600 psi)
Input Torque Versus Speed
@ 93°C (200°F), full flow and
1.0 bar absolute (0 psi gauge) inlet
70 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance
Mobile
PVM131
17 bar (250 psi)
50 bar (700 psi)
100 bar (1500 psi)
250 bar (3600 psi)
150 bar (2200 psi)
200 bar (2900 psi)
280 bar (4000 psi)
320 bar (4600 psi)
Speed – r/min
0 500 1000 1500 2000 2500
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
60 (80)
70 (94)
80 (107)
90 (121)
100 (134)
110 (148)
120 (161)
130 (174)
140 (188)
Input Power – kW (hp)
0
Input Power Versus Speed
@93°C (200°F), full flow and
1.0 bar absolute (0 psi gauge) inlet
20 bar (300 psi)
differential,
Input Torque
11 bar (160 psi)
differential,
Input Torque
11 bar (160 psi) differential
Case Flow
20 bar (300 psi) differential
Case Flow
Speed – r/min
Input Torque – Nm (in.lb.)
Case Flow (l/min (USgpm)
7 (1.85)
6 (1.58)
5 (1.32)
3 (0.79)
4 (1.06)
18 (159)
16 (142)
14 (124)
12 (106)
10 (88)
8 (71)
6 (53)
4 (35)
2 (18)
0
0 500 1000 1500 2000 2500
Input Torque and Case Flow Versus Speed
@ 93°C (200°F), load sense standby
and 1.0 bar absolute (0 psi gauge) inlet
17 bar (250 psi)
50 bar (700 psi)
100 bar (1500 psi)
250 bar (3600 psi)
150 bar (2200 psi)
200 bar (2900 psi)
280 bar (4000 psi)
320 bar (4600 psi)
Speed – r/min
0 500 1000 1500 2000 2500
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
60 (80)
70 (94)
80 (107)
90 (121)
100 (134)
110 (148)
120 (161)
130 (174)
140 (188)
Input Power – kW (hp)
0
Input Power Versus Speed
@93°C (200°F), full flow and
1.0 bar absolute (0 psi gauge) inlet
20 bar (300 psi)
differential,
Input Torque
11 bar (160 psi)
differential,
Input Torque
11 bar (160 psi) differential
Case Flow
20 bar (300 psi) differential
Case Flow
Speed – r/min
Input Torque – Nm (in.lb.)
Case Flow (l/min (USgpm)
7 (1.85)
6 (1.58)
5 (1.32)
3 (0.79)
4 (1.06)
18 (159)
16 (142)
14 (124)
12 (106)
10 (88)
8 (71)
6 (53)
4 (35)
2 (18)
0
0 500 1000 1500 2000 2500
Input Torque and Case Flow Versus Speed
@ 93°C (200°F), load sense standby
and 1.0 bar absolute (0 psi gauge) inlet
260 (2301)
240 (2124)
220 (1947)
200 (1770)
180 (1593)
160 (1416)
140 (1239)
120 (1062)
100 (885)
80 (708)
60 (531)
40 (354)
20 (177)
0 500 1000 1500 2000 2500
8 (2.1)
16 (4.2)
24 (6.3)
32 (8.5)
40 (10.6)
48 (12.7)
56 (14.8)
Case Flow – l/min (USgpm)
Input Torque – Nm (in.lb.)
Speed – r/min
280 bar (4000 psi)
Input Torque
150 bar (2200 psi)
Input Torque
150 bar (2200 psi), Case Flow
280 bar (4000 psi), Case Flow
Input Torque and Case Flow Versus Speed
@ 93°C (200°F), cut-off and
1.0 bar absolute (0 psi gauge) inlet
18 (4.7)
16 (4.2)
14 (3.7)
12 (3.2)
10 (2.6)
8 (2.1)
6 (1.6)
4 (1.0)
2 (0.5)
Case Flow – l/min (USgpm)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
Case Flow at 2000 r/min, Full Flow
93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet
28 (7.4)
24 (6.3)
20 (5.3)
16 (4.2)
12 (3.2)
8 (2.1)
4 (1.0)
Case Flow at 2000 r/min, Minimum Flow
93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet
Case Flow l/min (USgpm)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure – bar (psi)
250
(3600)
71EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
300 (79)
0
10
20
30
40
50
60
70
80
90
100
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1500 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
300 (79)
0
10
20
30
40
50
60
70
80
90
100
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1800 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
100 (134)
125 (168)
150 (201)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Input Torque,
Cut-off
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1500 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
100 (134)
125 (168)
150 (201)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
Input Torque,
Full Stroke
Input Power,
Full Stroke
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
300 (79)
0
10
20
30
40
50
60
70
80
90
100
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1500 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
300 (79)
0
10
20
30
40
50
60
70
80
90
100
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1800 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
100 (134)
125 (168)
150 (201)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Input Torque,
Cut-off
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1500 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
100 (134)
125 (168)
150 (201)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
Input Torque,
Full Stroke
Input Power,
Full Stroke
Performance
Industrial
PVM141
Noise Level – dBA
Typical Noise Levels at 1800 and 1200 r/min
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
60
62
64
66
68
70
72
74
1200 r/min
max. flow
76
78
80
82
84
1800 r/min
max. flow
1800 r/min
min. flow
1200 r/min
min. flow
Sound pressure data
equivalent to NFPA.
Noise Level – dBA
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
54
56
58
60
62
64
66
68
70
72
74
76
78
1500 r/min
max. flow
1000 r/min
min. flow
1000 r/min
max. flow
Typical Noise Levels 1500 and 1000 r/min
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
1500 r/min
min. flow
Noise Level – dBA
Typical Noise Levels at 1800 and 1200 r/min
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
60
62
64
66
68
70
72
74
1200 r/min
max. flow
76
78
80
82
84
1800 r/min
max. flow
1800 r/min
min. flow
1200 r/min
min. flow
Sound pressure data
equivalent to NFPA.
Noise Level – dBA
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
54
56
58
60
62
64
66
68
70
72
74
76
78
1500 r/min
max. flow
1000 r/min
min. flow
1000 r/min
max. flow
Typical Noise Levels 1500 and 1000 r/min
with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
1500 r/min
min. flow
72 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance
Industrial
PVM141
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
300 (79)
0
10
20
30
40
50
60
70
80
90
100
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1500 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
300 (79)
0
10
20
30
40
50
60
70
80
90
100
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1800 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
100 (134)
125 (168)
150 (201)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Input Torque,
Cut-off
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1500 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
100 (134)
125 (168)
150 (201)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
Input Torque,
Full Stroke
Input Power,
Full Stroke
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
300 (79)
0
10
20
30
40
50
60
70
80
90
100
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1500 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
300 (79)
0
10
20
30
40
50
60
70
80
90
100
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1800 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
100 (134)
125 (168)
150 (201)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Input Torque,
Cut-off
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1500 r/min, 50ϒC (120ϒF),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
100 (134)
125 (168)
150 (201)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
Input Torque,
Full Stroke
Input Power,
Full Stroke
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
300 (79)
0
10
20
30
40
50
60
70
80
90
100
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1000 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
300 (79)
0
10
20
30
40
50
60
70
80
90
100
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1200 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
100 (134)
125 (168)
150 (201)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Outlet Pressure – bar (psi)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1000 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
100 (134)
125 (168)
150 (201)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
Input Torque,
Full Stroke
Input Power,
Full Stroke
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
300 (79)
0
10
20
30
40
50
60
70
80
90
100
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1000 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
300 (79)
0
10
20
30
40
50
60
70
80
90
100
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1200 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
100 (134)
125 (168)
150 (201)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Outlet Pressure – bar (psi)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1000 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
100 (134)
125 (168)
150 (201)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
Input Torque,
Full Stroke
Input Power,
Full Stroke
73EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
7,6 (2.0)
6,6 (1.75)
5,7 (1.5)
4,7 (1.25)
3,8 (1.0)
2,8 (0.75)
1,9 (0.5)
0,9 (0.25)
0
Case Flow - l/min (USgpm)
Case Flow Versus Outlet Pressure at Full Flow, 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure - bar (psi)
250
(3600)
Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min
50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
22,7 (6)
18,9 (5)
15,1 (4)
11,4 (3)
7,6 (2)
3.8 (1)
0
Case Flow - l/min (USgpm)
0
100
(1500)
50
(700)
200
(2900)
150
(2200)
300
(4400)
350
(5000)
Outlet Pressure - bar (psi)
250
(3600)
Performance
Industrial
PVM141
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
300 (79)
0
10
20
30
40
50
60
70
80
90
100
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1000 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
300 (79)
0
10
20
30
40
50
60
70
80
90
100
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1200 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
100 (134)
125 (168)
150 (201)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Outlet Pressure – bar (psi)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1000 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
100 (134)
125 (168)
150 (201)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
Input Torque,
Full Stroke
Input Power,
Full Stroke
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
300 (79)
0
10
20
30
40
50
60
70
80
90
100
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Efficiency – %
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1000 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
Delivery – l/min (USgpm)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
300 (79)
0
10
20
30
40
50
60
70
80
90
100
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1200 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
100 (134)
125 (168)
150 (201)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
Input Power,
Full Stroke
Input Torque,
Full Stroke
Outlet Pressure – bar (psi)
0 100
(1500)
50
(700)
200
(2900)
150
(2200)
Outlet Pressure – bar (psi)
250
(3600)
Input Torque – Nm (in.lb.)
Input Power – kW (hp)
Input Torque and Power at 1000 r/min, 50°C (120°F),
and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
100 (134)
125 (168)
150 (201)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
Input Torque,
Full Stroke
Input Power,
Full Stroke
74 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance
Mobile
PVM141
Noise Level – dBA
Typical Noise Levels at 2000 and 1000 r/min
with Petroleum Oil (10W) at 93°C (200°F), and
1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
64
66
68
70
72
74
76
78
80
82
84
86
88
2000 r/min
min. flow
2000 r/min
max. flow
1000 r/min
min. flow
1000 r/min
max. flow
Sound pressure data
equivalent to NFPA.
0
Speed (r/min)
Overall Efficiency (%)
Overall Efficiency versus Speed at 93°C (200°F),
and 1.0 bar absolute (0 psi gauge) Inlet
55
65
75
85
95
500 1000 1500 2000 2500
50
60
70
80
100
100 bar (1500 psi)
150 bar (2200 psi)
50 bar
(700 psi)
210 bar (3000 psi)
230 bar (3300 psi)
90
Delivery and Case Flow versus Speed at
93°C (200°F), Full Flow and 1.0 bar absolute
(0 psi gauge) Inlet
0
Speed (r/min)
80 (21)
120 (32)
160 (42)
200 (53)
240 (63)
500 1000 1500 2000 2500
60 (16)
100 (26)
140 (37)
180 (48)
220 (58)
260 (69)
280 (74)
40 (11)
20 (5)
0
8 (2.1)
6 (1.6)
10 (2.6)
4 (1.1)
2 (0.5)
Delivery – l/min (USgpm)
Case
Flow
l/min
(USgpm)
100 bar
(1500 psi)
Delivery
210 bar (3000
psi) Case Flow
210 bar (3000
psi) Delivery
100 bar (1500 psi) Case Flow
Noise Level – dBA
Typical Noise Levels at 2000 and 1000 r/min
with Petroleum Oil (10W) at 93°C (200°F), and
1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
64
66
68
70
72
74
76
78
80
82
84
86
88
2000 r/min
min. flow
2000 r/min
max. flow
1000 r/min
min. flow
1000 r/min
max. flow
Sound pressure data
equivalent to NFPA.
0
Speed (r/min)
Overall Efficiency (%)
Overall Efficiency versus Speed at 93°C (200°F),
and 1.0 bar absolute (0 psi gauge) Inlet
55
65
75
85
95
500 1000 1500 2000 2500
50
60
70
80
100
100 bar (1500 psi)
150 bar (2200 psi)
50 bar
(700 psi)
210 bar (3000 psi)
230 bar (3300 psi)
90
Delivery and Case Flow versus Speed at
93°C (200°F), Full Flow and 1.0 bar absolute
(0 psi gauge) Inlet
0
Speed (r/min)
80 (21)
120 (32)
160 (42)
200 (53)
240 (63)
500 1000 1500 2000 2500
60 (16)
100 (26)
140 (37)
180 (48)
220 (58)
260 (69)
280 (74)
40 (11)
20 (5)
0
8 (2.1)
6 (1.6)
10 (2.6)
4 (1.1)
2 (0.5)
Delivery – l/min (USgpm)
Case
Flow
l/min
(USgpm)
100 bar
(1500 psi)
Delivery
210 bar (3000
psi) Case Flow
210 bar (3000
psi) Delivery
100 bar (1500 psi) Case Flow
Noise Level – dBA
Typical Noise Levels at 2000 and 1000 r/min
with Petroleum Oil (10W) at 93°C (200°F), and
1.0 bar absolute (0 psi gauge) Inlet
050
(700)
100
(1500)
150
(2200)
200
(2900)
250
(3600)
Outlet Pressure – bar (psi)
64
66
68
70
72
74
76
78
80
82
84
86
88
2000 r/min
min. flow
2000 r/min
max. flow
1000 r/min
min. flow
1000 r/min
max. flow
Sound pressure data
equivalent to NFPA.
0
Speed (r/min)
Overall Efficiency (%)
Overall Efficiency versus Speed at 93°C (200°F),
and 1.0 bar absolute (0 psi gauge) Inlet
55
65
75
85
95
500 1000 1500 2000 2500
50
60
70
80
100
100 bar (1500 psi)
150 bar (2200 psi)
50 bar
(700 psi)
210 bar (3000 psi)
230 bar (3300 psi)
90
Delivery and Case Flow versus Speed at
93°C (200°F), Full Flow and 1.0 bar absolute
(0 psi gauge) Inlet
0
Speed (r/min)
80 (21)
120 (32)
160 (42)
200 (53)
240 (63)
500 1000 1500 2000 2500
60 (16)
100 (26)
140 (37)
180 (48)
220 (58)
260 (69)
280 (74)
40 (11)
20 (5)
0
8 (2.1)
6 (1.6)
10 (2.6)
4 (1.1)
2 (0.5)
Delivery – l/min (USgpm)
Case
Flow
l/min
(USgpm)
100 bar
(1500 psi)
Delivery
210 bar (3000
psi) Case Flow
210 bar (3000
psi) Delivery
100 bar (1500 psi) Case Flow
75EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Performance
Mobile
PVM141
Input Torque and Case Flow versus Speed at 93°C
(200°F), Load Sense Standby and 1.0 bar absolute
(0 psi gauge) Inlet
0
Speed (r/min)
Input Torque – Nm (in.lb.)
4 (35)
6 (53)
8 (71)
10 (89)
12 (106)
500 1000 1500 2000 2500
3 (27)
5 (44)
7 (62)
9 (80)
11 (97)
13 (115)
14 (124)
2 (18)
1 (9)
5.0 (1.32)
4.5 (1.19)
5.5 (1.45)
4.0 (1.06)
3.5 (0.92)
3.0 (0.79)
6.0 (1.58)
6.5 (1.72)
11 bar (160 psi)
diff. Case Flow
20 bar (290 psi)
diff. Input Torque
Case
Flow l/min
(USgpm)
20 bar (290 psi)
diff. Case Flow
11 bar (160 psi)
diff. Input Torque
0
Speed (r/min)
Input Power – kW (hp)
Input Power versus Speed, 93°C (200°F),
and 1.0 bar absolute (0 psi gauge) Inlet
20 (27)
40 (54)
60 (80)
80 (107)
100 (134)
500 1000 1500 2000 2500
10 (13)
30 (40)
50 (67)
70 (94)
90 (121)
110 (148)
120 (161)
50 bar
(700 psi)
17 bar
(250 psi)
150 bar
(2200 psi)
100 bar
(1500 psi)
210 bar
(3000 psi)
230 bar
(3300 psi)
0 1000500 20001500
Speed (r/min)
2500
Input Torque – Nm (in.lb.)
Input Torque versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
3000
150 bar (2200 psi)
100 bar (1500 psi)
50 bar (725 psi)
350 (2655)
230 bar (3300 psi)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
17 bar (250 psi)
210 bar (3000 psi)
0
Speed (r/min)
Input Torque – Nm (in.lb.)
Input Torque and Case Flow versus Speed
at 93°C (200°F), Pressure Limit Cut-Off and
1.0 bar absolute (0 psi gauge) Inlet
20 (177)
40 (354)
60 (531)
80 (708)
110 (973)
500 1000 1500 2000 2500
10 (88)
30 (265)
50 (442)
70 (619)
90 (796)
100 (885)
0
20 (5.3)
15 (2.6)
10 (4.0)
5 (1.3)
210 bar (3000 psi)
Case Flow
150 bar (2200 psi)
Input Torque
Case Flow
l/min
(USgpm)
150 bar (2200 psi)
Case Flow
210 bar (3000 psi)
Input Torque
Input Torque and Case Flow versus Speed at 93°C
(200°F), Load Sense Standby and 1.0 bar absolute
(0 psi gauge) Inlet
0
Speed (r/min)
Input Torque – Nm (in.lb.)
4 (35)
6 (53)
8 (71)
10 (89)
12 (106)
500 1000 1500 2000 2500
3 (27)
5 (44)
7 (62)
9 (80)
11 (97)
13 (115)
14 (124)
2 (18)
1 (9)
5.0 (1.32)
4.5 (1.19)
5.5 (1.45)
4.0 (1.06)
3.5 (0.92)
3.0 (0.79)
6.0 (1.58)
6.5 (1.72)
11 bar (160 psi)
diff. Case Flow
20 bar (290 psi)
diff. Input Torque
Case
Flow l/min
(USgpm)
20 bar (290 psi)
diff. Case Flow
11 bar (160 psi)
diff. Input Torque
0
Speed (r/min)
Input Power – kW (hp)
Input Power versus Speed, 93°C (200°F),
and 1.0 bar absolute (0 psi gauge) Inlet
20 (27)
40 (54)
60 (80)
80 (107)
100 (134)
500 1000 1500 2000 2500
10 (13)
30 (40)
50 (67)
70 (94)
90 (121)
110 (148)
120 (161)
50 bar
(700 psi)
17 bar
(250 psi)
150 bar
(2200 psi)
100 bar
(1500 psi)
210 bar
(3000 psi)
230 bar
(3300 psi)
0 1000500 20001500
Speed (r/min)
2500
Input Torque – Nm (in.lb.)
Input Torque versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
3000
150 bar (2200 psi)
100 bar (1500 psi)
50 bar (725 psi)
350 (2655)
230 bar (3300 psi)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
17 bar (250 psi)
210 bar (3000 psi)
0
Speed (r/min)
Input Torque – Nm (in.lb.)
Input Torque and Case Flow versus Speed
at 93°C (200°F), Pressure Limit Cut-Off and
1.0 bar absolute (0 psi gauge) Inlet
20 (177)
40 (354)
60 (531)
80 (708)
110 (973)
500 1000 1500 2000 2500
10 (88)
30 (265)
50 (442)
70 (619)
90 (796)
100 (885)
0
20 (5.3)
15 (2.6)
10 (4.0)
5 (1.3)
210 bar (3000 psi)
Case Flow
150 bar (2200 psi)
Input Torque
Case Flow
l/min
(USgpm)
150 bar (2200 psi)
Case Flow
210 bar (3000 psi)
Input Torque
Input Torque and Case Flow versus Speed at 93°C
(200°F), Load Sense Standby and 1.0 bar absolute
(0 psi gauge) Inlet
0
Speed (r/min)
Input Torque – Nm (in.lb.)
4 (35)
6 (53)
8 (71)
10 (89)
12 (106)
500 1000 1500 2000 2500
3 (27)
5 (44)
7 (62)
9 (80)
11 (97)
13 (115)
14 (124)
2 (18)
1 (9)
5.0 (1.32)
4.5 (1.19)
5.5 (1.45)
4.0 (1.06)
3.5 (0.92)
3.0 (0.79)
6.0 (1.58)
6.5 (1.72)
11 bar (160 psi)
diff. Case Flow
20 bar (290 psi)
diff. Input Torque
Case
Flow l/min
(USgpm)
20 bar (290 psi)
diff. Case Flow
11 bar (160 psi)
diff. Input Torque
0
Speed (r/min)
Input Power – kW (hp)
Input Power versus Speed, 93°C (200°F),
and 1.0 bar absolute (0 psi gauge) Inlet
20 (27)
40 (54)
60 (80)
80 (107)
100 (134)
500 1000 1500 2000 2500
10 (13)
30 (40)
50 (67)
70 (94)
90 (121)
110 (148)
120 (161)
50 bar
(700 psi)
17 bar
(250 psi)
150 bar
(2200 psi)
100 bar
(1500 psi)
210 bar
(3000 psi)
230 bar
(3300 psi)
0 1000500 20001500
Speed (r/min)
2500
Input Torque – Nm (in.lb.)
Input Torque versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
3000
150 bar (2200 psi)
100 bar (1500 psi)
50 bar (725 psi)
350 (2655)
230 bar (3300 psi)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
17 bar (250 psi)
210 bar (3000 psi)
0
Speed (r/min)
Input Torque – Nm (in.lb.)
Input Torque and Case Flow versus Speed
at 93°C (200°F), Pressure Limit Cut-Off and
1.0 bar absolute (0 psi gauge) Inlet
20 (177)
40 (354)
60 (531)
80 (708)
110 (973)
500 1000 1500 2000 2500
10 (88)
30 (265)
50 (442)
70 (619)
90 (796)
100 (885)
0
20 (5.3)
15 (2.6)
10 (4.0)
5 (1.3)
210 bar (3000 psi)
Case Flow
150 bar (2200 psi)
Input Torque
Case Flow
l/min
(USgpm)
150 bar (2200 psi)
Case Flow
210 bar (3000 psi)
Input Torque
Input Torque and Case Flow versus Speed at 93°C
(200°F), Load Sense Standby and 1.0 bar absolute
(0 psi gauge) Inlet
0
Speed (r/min)
Input Torque – Nm (in.lb.)
4 (35)
6 (53)
8 (71)
10 (89)
12 (106)
500 1000 1500 2000 2500
3 (27)
5 (44)
7 (62)
9 (80)
11 (97)
13 (115)
14 (124)
2 (18)
1 (9)
5.0 (1.32)
4.5 (1.19)
5.5 (1.45)
4.0 (1.06)
3.5 (0.92)
3.0 (0.79)
6.0 (1.58)
6.5 (1.72)
11 bar (160 psi)
diff. Case Flow
20 bar (290 psi)
diff. Input Torque
Case
Flow l/min
(USgpm)
20 bar (290 psi)
diff. Case Flow
11 bar (160 psi)
diff. Input Torque
0
Speed (r/min)
Input Power – kW (hp)
Input Power versus Speed, 93°C (200°F),
and 1.0 bar absolute (0 psi gauge) Inlet
20 (27)
40 (54)
60 (80)
80 (107)
100 (134)
500 1000 1500 2000 2500
10 (13)
30 (40)
50 (67)
70 (94)
90 (121)
110 (148)
120 (161)
50 bar
(700 psi)
17 bar
(250 psi)
150 bar
(2200 psi)
100 bar
(1500 psi)
210 bar
(3000 psi)
230 bar
(3300 psi)
0 1000500 20001500
Speed (r/min)
2500
Input Torque – Nm (in.lb.)
Input Torque versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
3000
150 bar (2200 psi)
100 bar (1500 psi)
50 bar (725 psi)
350 (2655)
230 bar (3300 psi)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
17 bar (250 psi)
210 bar (3000 psi)
0
Speed (r/min)
Input Torque – Nm (in.lb.)
Input Torque and Case Flow versus Speed
at 93°C (200°F), Pressure Limit Cut-Off and
1.0 bar absolute (0 psi gauge) Inlet
20 (177)
40 (354)
60 (531)
80 (708)
110 (973)
500 1000 1500 2000 2500
10 (88)
30 (265)
50 (442)
70 (619)
90 (796)
100 (885)
0
20 (5.3)
15 (2.6)
10 (4.0)
5 (1.3)
210 bar (3000 psi)
Case Flow
150 bar (2200 psi)
Input Torque
Case Flow
l/min
(USgpm)
150 bar (2200 psi)
Case Flow
210 bar (3000 psi)
Input Torque
76 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
End-ported
Models
PVM018/020
Dimensions in millimeters (inches)
B
Control position for right hand
(cloc kwise) shaft rotation, as
viewed from shaft end. Position
for left hand rotation is shown on
following page.
165,7
(6.52)
85,1
(3.35)
55,2
(2.17)
MM
C
D
G (with adj. max. stop)
Adjustable maximum displacement
stop (1 turn = 1.1 cm
3
/rev). CCW
reduces displacement.
L
K
J
23,0
(.91)
Inlet gauge
port “K.”
See options
on page 107.
34,0
(1.34)
34,5
(1.36)
Outlet port “C.”
See options on page 106.
37,4
(1.47)
Drain port
F.” See
options on
page 107.
A
H (without adj. max. stop)
Inlet port “B.”
See options
on page 106.
Alt. drain port “F.” (See options on page 107.)
Load sense port “J.” (See options on page 107.)
Drain port “F” (See options on page 107.)
See shaft options starting on page 102.
58,0
(2.28)
76,0
(2.99)
73,0
(2.87)
72,0
(2.83)
72,0
(2.83)
58,0
(2.28)
F
E
77EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
End-ported
Models
PVM018/020
Control position for left hand
rotation (Pressure compensated
control shown)
Inlet position for right hand rotation (Position
for left hand rotation shown below).
Adjustable maximum displacement
stop (1 turn = 1.1 cm
3
/rev). CCW
reduces displacement.
Dimensions in millimeters (inches)
Control position for right hand
rotation (Load sensing control
shown)
Inlet position for left hand
rotation (Position for right
hand rotation shown above)
Outlet
Outlet
Inlet/Outlet Ports and Control
Positioned for Left Hand Rotation
Inlet/Outlet Ports and Control
Positioned for Ri gh t Hand Rotation
37,4
(1.47)
34,0
(1.34)
34,5
(1.36)
37,5
(1.48)
140,5
(5.53)
126,3
(4.97)
165,7
(6.52)
Control position for left hand
rotation (Pressure compensated
control shown)
Inlet position for right hand rotation (Position
for left hand rotation shown below).
Adjustable maximum displacement
stop (1 turn = 1.1 cm
3
/rev). CCW
reduces displacement.
Dimensions in millimeters (inches)
Control position for right hand
rotation (Load sensing control
shown)
Inlet position for left hand
rotation (Position for right
hand rotation shown above)
Outlet
Outlet
Inlet/Outlet Ports and Control
Positioned for Left Hand Rotation
Inlet/Outlet Ports and Control
Positioned for Ri gh t Hand Rotation
37,4
(1.47)
34,0
(1.34)
34,5
(1.36)
37,5
(1.48)
140,5
(5.53)
126,3
(4.97)
165,7
(6.52)
78 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Side-ported
Models
PVM018/020
Alt. drain
port “F.” See
options on
page 107.
Outlet port “C” (above).
See options on page 106.
Dimensions in millimeters (inches)
M
E
Load sense port “J”
(See options on page 107)
See shaft options starting
on page 102.
Drain port “F”
(See options on page 107)
72,0
(2.83)
72,0
(2.83)
58,0
(2.28)
F
Alt. drain port “F”
(See options on page 107)
108,8
(4.28)
85,1
(3.35)
55,2
(2.17)
C
D
MM
A
B
G (with adj. max. stop)
H (without adj. max. stop)
23,0
(.91)
Adjustable maximum displacement
stop (1 turn = 1.1 cm
3
/rev). CCW
reduces displacement.
J
K
L
Inlet port “B.”
See options on page 106.
62,9
(2.48)
62,9
(2.48)
21,9
(.86)
21,6
(.85)
Inlet gauge
port “K.”
See options
on page 107.
Outlet
gauge
port “K.”
See
options
on page 107.
Control position for right hand
(clockwise) shaft rotation , as viewed
from shaft end. Position for left hand
rotation is shown on following page.
114,7
(4.52)
Outlet port “C.”
See options on page 106.
M
N
To pilot
mtg. flg.
outlet
port “C.”
C
L
79EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Side-ported
Models
PVM018/020
Inlet gauge port “K.” See
options on page
107.
Adjustable maximum displacement
stop (1 turn = 1.1 cm
3
/rev). CCW
reduces displacement.
Dimensions in millimeters (inches)
Control position for right hand
rotation (Load sensing control
shown)
Control position for left hand r otation
(Pressure compensated control shown)
Inlet position for left hand
rotation (Position for right
hand rotation shown above)
Outlet
Inlet position for right hand r otation (Position
for left hand rotation shown below)
Outlet
Inlet/Outlet Ports and Control
Positioned for Left Hand Rotation
Inlet/Outlet Ports and Control
Positioned for Ri gh t Hand Rotation
62,9
(2.48)
21,9
(.86)
86,5
(3.41)
21,6
(.85)
62,9
(2.48)
Outlet gauge port “K.”
See options on page
107.
72,3
(2.85)
Outlet gauge port “K.” See
options on page
107.
Inlet gauge port “K.”
Seep options on page
107.
114,7
(4.52)
Inlet gauge port “K.” See
options on page
107.
Adjustable maximum displacement
stop (1 turn = 1.1 cm
3
/rev). CCW
reduces displacement.
Dimensions in millimeters (inches)
Control position for right hand
rotation (Load sensing control
shown)
Control position for left hand r otation
(Pressure compensated control shown)
Inlet position for left hand
rotation (Position for right
hand rotation shown above)
Outlet
Inlet position for right hand r otation (Position
for left hand rotation shown below)
Outlet
Inlet/Outlet Ports and Control
Positioned for Left Hand Rotation
Inlet/Outlet Ports and Control
Positioned for Ri gh t Hand Rotation
62,9
(2.48)
21,9
(.86)
86,5
(3.41)
21,6
(.85)
62,9
(2.48)
Outlet gauge port “K.”
See options on page
107.
72,3
(2.85)
Outlet gauge port “K.” See
options on page
107.
Inlet gauge port “K.”
Seep options on page
107.
114,7
(4.52)
80 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Thru-drive
Models
PVM018/020
Dimensions in millimeters (inches)
164,2
(6.46)
124,0
(4.88)
Load sense port “J”
(See options on page 107)
Drain port “F”
(See options on page 107)
72,0
(2.83)
72,0
(2.83)
58,0
(2.28)
26,1
(1.03)
Alt. drain port “F”
(See options on page 107)
108,1
(4.14)
85,1
(3.35)
60,0
(2.36)
C
D
M
A
B
221,4 (8.72)
with adj. max. stop
212,3 (8.36)
without adj. max. stop
23,0
(.91)
Adjustable maximum displacement
stop (1 turn = 1.1 cm
3
/rev). CCW
reduces displacement.
99,0
(3.90)
167,7
(6.60)
223,2
(8.79)
Inlet port “B.”
See options
on page 106.
Alt. drain port “F.
See options on page 107.
114,7
(4.52)
62,9
(2.48)
64,2
(2.53)
Control position for right hand
(clockwise) shaft rotation, as viewed
from shaft end. Position for left hand
rotation is shown on following page.
Centerline of
outlet port
M
Outlet port “C.”
See options on page 106
164,2
(6.46)
to pilot
mtg. flg.
See shaft options starting
on page 107.
81EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Thru-drive
Models
PVM018/020
Adjustable maximum displacement stop
(1 turn = 1.1 cm
3
/rev). CCW reduces
displacement.
Dimensions in millimeters (inches)
Control position for right hand
rotation (Load sensing control
shown)
Control position for left hand rotation
(Pressure compensator control shown)
Inlet position for left hand
rotation (Position for right
hand rotation shown above)
Outlet
Inlet position for right hand
rotation (Position for left hand
rotation shown below)
Outlet
114,7
(4.52)
62,9
(2.48)
64,2
(2.53)
Inlet/Outlet Ports and Control
Positioned for
L
e
ft
H
a
nd
R
o
t
a
t
ion
Inlet/Outlet Ports and Control
Positioned for
R
igh
t
H
a
nd
R
o
t
a
t
ion
86,5
(3.41)
72,3
(2.85)
79,4
(3.13)
20,0
(0.79)
20,0
(0.79)
HH
K (2 places)
N (2 places)
159,2
(6.27)
57,49
(2.26)
40,46
(1.59)
12,25
(0.48)
53,5
(2.11)
8,50
(0.33)
2,00 (0.079)
1,90 (0.075)
89,70 (3.531)
89,60 (3.527)
G
27,00
(1.06)
Output shaft 21T, 32/64 DP,
30° PA involute spline.
Model Code Position 25 ØG H K N
A,B 82,625 (3.253)
53,2 (2.09)
375-16 UNC-2B thd. 375-16 UNC-2B thd.
82,575 (3.251) 0.75 deep min 0.62 deep min.
G,H 80,046 (3.151)
54,5 (2.15)
M10 x 1,50 thd. M10 x 1,50 thd.
80,002 (3.150) 19,05 deep min 15,88 deep min.
Model Code Position 25
Description
A For SAE “A” pad with a 9T, 16/32 DP, 30° pressure angle,
involute spline
B For SAE “A” pad with a 11T, 16/32 DP, 30° pressure angle,
involute spline
G For ISO 80 A2HW pad with a 9T SAE spline
H For ISO 80 A2HW pad with a 11T SAE spline
82 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Flange
Designations
PVM018/020
“A” Pilot Flange
Designation ØA B C D E F G H J K L M
SAE J744-82-2 82,55 11,35/10,97 106,4 53,2
Model Code A (3.25) (.447/.432) (4.19) (2.09)
131,5 33,6 228,9 219,8 106,5 166,7 200,7 65,2
ISO 3019/2-80A2HW 80,00 11,27/11,00 109,0 54,5
(5.18) (1.32) (9.00) (8.65) (4.19) (6.56) (7.90) (2.57)
Model Code B (3.15) (.444/.433) (4.29) (2.15)
“B” Pilot Flange
Designation
SAE J744-101-2 101,60 14,55/14,17 146,0 73,0
Model Code C (4.00) (.572/.557) (5.750) (2.875)
124,0 26,1 221,4 212,3 99,0 159,2 193,9 87,0
ISO 3019/2-100A2HW 100,00 14,27/14,00 140,0 70,0
(4.88) (1.03) (8.72) (8.36) (3.90) (6.27) (7.63) (3.43)
Model Code D (3.937) (.562/.551) (5.512) (2.756)
Pilot Flange Designation ØA B C D
SAE J744-127-2 Model Code C 101,60 (4.00) 14,55/14,17 (.572/.558) 146,0 (5.75) 73,0 (2.87)
ISO 3019/2-100 A2HW Model Code D 100,00 (3.94) 14,27/14,00 (.562/.551) 140,0 (5.51) 70,0 (2.76)
83EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
End-ported
Models
PVM045/050
80,0
(3.20)
135,4 (5.33)
175,0 (6.89)
75,1
(2.96)
87,1
(3.43)
174,0 (6.85)
178,6 (7.03)
B
Load sense port “J.” See
options on page
107.
212,0 (8.350)
Outlet gauge port “K.” See
options on page
107.
Alternate
drain
port “F”
19,1
(0.75)
Alternate load
sense port “J”
42,0
(1.65)
Inlet port “B.” See
options on page 106.
47,8 (1.88)
53,0
(2.09)
44,6 (1.75)
130,6
(5.14)
D
87,0
(3.425)
C
E
A
80,0
(3.15)
80,0
(3.20)
134,3 (5.29) max.
28,0 (1.10)
36,9 (1.45)
Drain port “F.” See
options on page
107
.
80,0
(3.15)
Adjustable maximum
displacement stop
(1 turn = 2 cm
3
/rev).
Control position for left hand (countercloc kwise)
shaft rotation , as viewed from shaft end.
Position for right hand rotation is shown on
following page.
Alternate drain port “F”
257,0 (10.12) max.
247,0 (9.72)
Inlet gauge port “K”
Outlet port “C.” See
options on page 106.
Dimensions in millimeters (inches)
Load sensing control
(See pressure compensated
control on following page.)
See shaft options starting
on page 102.
84 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
End-ported
Models
PVM045/050
Dimensions in millimeters (inches)
Non-maximum adjustment
stop control cap. See
preceding page for adjustable
maximum displacement stop
138,5
(5.45)
Control position for
left hand rotation
98,9 (3.89)
121,8 (4.80) max.
34,4 (1.35)
4,0 (0.16)
Control position for right hand
rotation (Pressure compensated
control shown)
Control position for
right hand rotation
Control position for left
hand rotation (Load
sensing control shown)
75,1
(2.96)
87,1
(3.43)
47,8 (1.88)
53,0
(2.09)
Inlet position for left hand
rotation (Position for right
hand rotation shown above)
Outlet
Inlet position for right hand
rotation (Position for left
hand rotation shown below)
Outlet
Inlet/Outlet Ports and Control Positioned
for Left Hand Rotation
Dimensions shown on preceding page.
Inlet/Outlet Ports and Control Positioned
for Ri ght Hand Rotation
Dimensions in millimeters (inches)
Non-maximum adjustment
stop control cap. See
preceding page for adjustable
maximum displacement stop
138,5
(5.45)
Control position for
left hand rotation
98,9 (3.89)
121,8 (4.80) max.
34,4 (1.35)
4,0 (0.16)
Control position for right hand
rotation (Pressure compensated
control shown)
Control position for
right hand rotation
Control position for left
hand rotation (Load
sensing control shown)
75,1
(2.96)
87,1
(3.43)
47,8 (1.88)
53,0
(2.09)
Inlet position for left hand
rotation (Position for right
hand rotation shown above)
Outlet
Inlet position for right hand
rotation (Position for left
hand rotation shown below)
Outlet
Inlet/Outlet Ports and Control Positioned
for Left Hand Rotation
Dimensions shown on preceding page.
Inlet/Outlet Ports and Control Positioned
for Ri ght Hand Rotation
85EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Side-ported
Models
PVM045/050
134.3
(5.29)
max.
135,4
(5.33)
87,0
(3.425)
174,0 (6.850)
78,0
(3.07)
109,1
(4.30)
191,6 (7.54)
75,5 (2.97)
Control position for right hand
(cloc kwise) shaft rotation, as viewed
from shaft end. Position for left hand
rotation is shown on following page.
Drain port “F.” See
options on page 107.
Load sense port
“J.” See options
on page 107.
Alternate drain port “F”
Inlet port “B.” See
options on page 106.
257,0
(10.12)
max.
178,6
(7.03)
36,9
(1.45)
42.0
(1.65)
42.0
(1.65)
168,2
(6.62)
230,0
(9.06)
183,0
(7.20)
208,0 (8.19)
Outlet port “C.”
See options
on page 106.
72,1
(2.84)
Alternate drain
port “F”
130,6
(5.14)
19,1 (0.75)
44,6 (1.75)
E
A
81,3
(3.20)
81,3
(3.20)
Adjustable max.
displacement
stop (1 turn = 2
cm
3
/rev)
Alternate load sense port “J”
B
Dimensions in millimeters (inches)
247,0 (9.72)
D
C
Z
Z
View Z-Z
72,5 (2.85)
69,0 (2.72)
Outlet gauge
port “K.”
See option
on page
107.
Inlet gauge
port “K”
57,50 (2.26)
50,0 (1.97)
Load sensing control (See pressure compensated
control on following page.)
See shaft
options starting
on page 102.
117,6
(4.63)
86 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Side-ported
Models
PVM045/050
Control position for left hand rotation
(Inlet/outlet port positions for left hand
rotation are the opposite of those
shown for right hand rotation on
preceding page.)
Dimensions in millimeters (inches)
72,5 (2.85)
69,0 (2.72)
Outlet gauge port
“K.” See options
on page
107
.
Inlet gauge
port “K”
57,50 (2.26)
50,0 (1.97)
Non-maximum adjustment stop control
cap. See preceding page for adjustable
maximum displacement stop.
138,5
(5.45)
Control position for left hand
rotation (Pressure compensated
control shown). Inlet/outlet port
positions for left hand rotation
are the opposite of those shown
for right hand rotation on
preceding page.
98,9 (3.89)
121,8 (4.80) max. 34,4 (1.35)
4,0 (0.16)
Control position for right hand rotation
(Inlet/outlet port positions for right hand
rotation are shown on preceding page.)
Outlet gauge port “K.” See
options on page
107.
Inlet gauge
port “K”
Control position for right hand rotation
(Load sensing control shown). Inlet/outlet
port positions for right hand rotation are
shown on preceding page.
Inlet/Outlet Ports and Control Positioned
for Right Hand Rotation
Dimensions shown on preceding page.
Inlet/Outlet Ports and Control Positioned
for Lef t Hand Rotation
Control position for left hand rotation
(Inlet/outlet port positions for left hand
rotation are the opposite of those
shown for right hand rotation on
preceding page.)
Dimensions in millimeters (inches)
72,5 (2.85)
69,0 (2.72)
Outlet gauge port
“K.” See options
on page
107.
Inlet gauge
port “K”
57,50 (2.26)
50,0 (1.97)
Non-maximum adjustment stop control
cap. See preceding page for adjustable
maximum displacement stop.
138,5
(5.45)
Control position for left hand
rotation (Pressure compensated
control shown). Inlet/outlet port
positions for left hand rotation
are the opposite of those shown
for right hand rotation on
preceding page.
98,9 (3.89)
121,8 (4.80) max. 34,4 (1.35)
4,0 (0.16)
Control position for right hand rotation
(Inlet/outlet port positions for right hand
rotation are shown on preceding page.)
Outlet gauge port “K.” See
options on page
107.
Inlet gauge
port “K”
Control position for right hand rotation
(Load sensing control shown). Inlet/outlet
port positions for right hand rotation are
shown on preceding page.
Inlet/Outlet Ports and Control Positioned
for Right Hand Rotation
Dimensions shown on preceding page.
Inlet/Outlet Ports and Control Positioned
for Lef t Hand Rotation
87EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Thru-drive
Models
PVM045/050
B
Dimensions in millimeters (inches)
View “A-A”
Outlet
port “C.”
See
options
on
page 106.
183,0
(7.20)
208,0
(8.19)
197,7
(7.78)
135,8
(5.35)
81,3
(3.20)
81,3
(3.20)
Alt. drain port
F.” See options
on page 107.
Drain port “F.” See options
on page 107.
36,9
(1.45)
68,8
(2.71)
72,3
(2.85)
Left Hand Rotation
121,8
(4.80)
34,4
(1.35)
98,9
(3.89)
Control position
for R.H. rotation
Control position
for L.H. rotation
138,5
(5.45)
133,3
(5.25)
110,8
(4.36)
44,6
(1.76)
34,1
(1.34)
Load sense port “J.”
See options on
page 107.
130,6
(5.14)
78,6
(3.09)
87,0
(3.43)
87,0
(3.43)
C
D
168,2
(6.62)
249,0
(9.80)
178,6
(7.03)
A
251,0
(9.88)
191,6
(7.54)
Drain port “F.
See options on
page 107.
11,0
(0.43)
42,0 (1.65)
117,6
(4.63)
Adjustable maximum displacement stop
(1 turn = 2.1 cm
3
/rev)
Load sense
control position
for R.H. rotation
Load sense
control position
for L.H. rotation
Ri ght Han d Rotation
Inlet port “B.”
See options on
page 106.
5,4
(0.21)
35,0
(1.38)
36,0
(1.42)
Inlet gauge port “K.”
See options on page 107.
Outlet gauge
port “K”
42,0
(1.65)
A
A
Ri gh t Hand Rotation with Load Sensing Control and Tube Ports
See shaft options starting
on page 102.
Flange
dependent
88 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Thru-drive
Models
PVM045/050
263,5
(10.37)
276,0
(10.87)
86,49
(3.41)
10,28
(0.40)
107,90 (4.248)
107,82 (4.244)
G
35,30
(1.39)
L (4 places)
77,47
(3.05)
11,75
(0.46)
2,00 (0.079)
1,90 (0.075)
86,0
(3.39)
2 plcs
86,0
(3.39)
2 plcs
H
H
K (2 places)
J (2 places)
J (2 places)
K (2 places)
M (4 places)
N (2 places)
Output shaft 26T, 32/64 DP,
30° PA involute spline.
53,0
(2.09)
53,0
(2.09)
N (2 places)
Output shaft 26T, 32/64 DP,
30° PA involute spline.
Dimensions in millimeters (inches)
HH
61,74
(2.43)
40,4
(1.59)
12,24
(0.482)
G
31,75
(1.25)
89,70 (3.531)
89,60 (3.527)
“A” Pad
“B” Pad
Model Code Position 25 ØG H J K L M N
A,B 82,58 (3.251) 53.2
.375-16 UNC-2B
82,52 (3.249) (2.09) thd. 0.60 deep min.
G,H
80,046 (3.15) 54,5
M10 thd. x 1,50
80,002 (3.149) (2.15) 15,0 deep min.
101,65 (4.002) 73,0 44,9 89,8
.500-13 UNC-2B thd. .500-13 UNC-2B .500-13 UNC-2B
C,D 24.9 deep min. M12 x thd. thru M10 x thd. thru
101,60 (4.00) (2.87) (1.77) (3.54)
1,50 thd. 24,9 deep min. 1,50 thd. thru M12 x 1,50 thd. thru
J,K
100,0 (3.937) 70,0 44,2 88,38 M12 thd. x 1,50 thd. M10 x 1,50 thd. M12 x 1,50 thd.
99,946 (3.935) (2.76) (1.74) (3.48) 24,9 deep min. thru thru
Model Code Position 25
Description
A For SAE “A” pad with a 9T,
16/32 DP, 30° pressure
angle, involute spline
B For SAE “A” pad with a 11T,
16/32 DP, 30° pressure
angle, involute spline
C For SAE “B” pad with a 13T,
16/32 DP, 30° pressure
angle, involute spline
D For SAE “B” pad with a 15T,
16/32 DP, 30° pressure
angle, involute spline
G For ISO 80-A2HW pad
with a 9T SAE spline
H For ISO 80-A2HW pad
with a 11T SAE spline
J For ISO 100-A2/B4HW pad
with a 13T SAE spline
89EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Flange
Designations
PVM045/050
Pilot Flange Designation ØA B C D E
SAE J744-101-2
101,60/101,55 9,70/9,19
146,0 (5.750) 73,0 (2.875)
14,55/14,17
(4.000/3.998) (.382/.362) (.572/.557)
ISO 3019/2-100A2HW
100,00/99,95 9,50/9,00
140,0 (5.512) 70,0 (2.756)
14,27/14,00
(3.937/3.935) (.374/.354) (.562/.551)
Pilot Flange Designation ØA B C D
SAE 2-bolt mount 101,60/101,55 (4.000/3.998) 73,0 (2.87) 146,0 (5.750) 14,55/14,17 (.572/.557)
ISO 100 2-bolt mount 100,00/99,95 (3.937/3.935) 70,0 (2.76) 140,0 (5.512) 14,27/14,00 (.562/.551)
90 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
End-ported
Models
PVM057/063
Drain port “F.”
Alternate drain port “F” on
opposite side. See options on page 107.
Dimensions in millimeters (inches)
Left Hand Rotation, Tube Port
with Pressure Compensator
Inlet port “B.”
See options on
Outlet port “C.” See
options on page 106.
206,2
(8.12)
116,0
(4.57)
Ri gh t Hand Rotation ,
Flange Port with Load Sensing Control
254,3
(10,0)
199,3
(7.85)
121,8
(4.80)
77,5
(3.05)
38,89
(1.53)
77,78
(3.06)
SAE .500-13
UNC-2B thd. 1.06
deep min.
ISO M12 x 1,75 thd.
29.0 deep min.
SAE .375-16
UNC-2B thd. .88
deep min. ISO M10 x 1,5 thd.
23.0 deep min.
52,38
(2.06)
26,19
(1.03)
165,6
(6.52)
42,88
(1.69)
88,7
(3.49)
75,7
(2.98)
21,44
(.84)
26,18
(1.03)
13,1
(.51)
292,2
(11.50)
87,0
(3.43)
245,4
(9.66)
201,4
(7.93)
102,8
(4.05)
Load sense port “J.”
See options on
page 107.
Outlet gauge port “K.”
Inlet gauge port “K” on
opposite side. See
options on page 107.
39,0
(1.54)
274,8
(10.82)
168,2
(6.62)
32,9
(1.30)
157,0
(6.18)
269,7
(10.62)
w/o adj. max. stop
w/adj. max. stop
See mounting flange options on page 101.
See shaft options starting on page 102.
Outlet port
“C.” See
options on
page 106.
Inlet port “B.” See options
on page 106.
82,3
(3.24)
82,3
(3.24)
page 106.
91EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Side-ported
Models
PVM057/063
Dimensions in millimeters (inches)
198,1
(7.80)
Left Hand Rotation with
Pressure Compensator
116,0
(4.57)
Ri gh t Hand Rotation with
Load Sensing Control
269,7
(10.62)
w/o adj. max. stop
274,8
(10.82)
168,2
(6.62)
32,9
(1.30)
157,0
(6.18)
224,4
(8.83)
To mounting face
42,88
(1.69)
21,44
(.84)
38,89
(1.53)
77,78
(3.06)
Adjustable maximum
displacement stop
1 turn = 2.98 l/min
(0.79 USgpm)
199,3
(7.85)
121,8
(4.80)
77,5
(3.05)
247,9
(9.76)
165,6
(6.52)
75,0
(2.95)
75,0
(2.95)
57,0
(2.24)
61,5
(2.42)
Inlet port “B.”
See options on
page 106.
SAE .500-13
UNC-2B thd.
1.06 deep min.
ISO M12 1,75
thd. 29.0 deep
min.
Outlet gauge port
“K.” See options
on page 107.
Drain port “F.Alternate drain port “F” on
opposite side. See options on page 107.
Inlet gauge port “K.”
See options
on page 107.
102,8
(4.05)
39,0
(1.54)
87,0
(3.43)
52,37
(2.06)
26,2
(1.03)
292,2
(11.50)
266,5
(10.49)
241,5
(9.51)
213,4
(8.40)
Load sense port “J.” See
options on page 107.
SAE .375-16
UNC-2B thd. .88
deep min.
ISO M10 x 1,5 thd.
23.0 deep min.
Outlet port
“C.” See
options on
page 106.
26,19
(1.03)
13,1
(.51)
See mounting flange options on page 101.
See shaft options starting on page 102.
82,3
(3.24)
82,3
(3.24)
w/adj. max. stop
92 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Thru-drive
Models
PVM057/063
89,0
(3.50)
Dimensions in millimeters (inches)
205,0
(8.07)
Left Hand Rotation with Pressure Compensator
and SAE 2-bolt “A” Flange (no adapter)
116,0
(4.57)
Outlet gauge port
“K.” See options
on page 107.
Inlet gauge port
“K.” See options
on page 107.
Inlet port “B.”
See options
on page 106.
M12 thd. 21,0 deep
(4 places)
R
T1 (2 places)
224,4
(8.83)
To mounting face
42,88
(1.69)
21,44
(.84)
SAE .500-13
UNC-2B thd.
1.06 deep min.
ISO M12 x 1,75 thd.
29.0 deep min.
38,89
(1.53)
77,78
(3.06)
199,3
(7.85)
121,8
(4.80)
77,5
(3.05)
254,6
(10,0)
165,6
(6.52)
12,0
(.47)
92,0
(3.62)
14,0
(.55)
Ri gh t Hand Rotation with Load Sensing Control
and SAE 2-bolt “A” Flange (no adapter)
80,1
(3.15)
44,8
(1.76)
S (See table
next page)
157,0
(6.18)
32,9
(1.30)
168,2
(6.62)
292,2
(11.5)
284,4
(11.2)
213,4
(8.40)
39,0
(1.54)
102,8
(4.05)
87,0
(3.43)
52,37
(2.06)
26,18
(1.03)
Drain port “F.Alternate drain
port “F” on opposite side.
See options on page 107.
Alternate drain port “F”
Load sense port “J.” See
options on page 107.
Outlet
port “C.”
See options
on page 106.
SAE .375-16
UNC-2B thd. .88
deep min.
ISO M10 x 1,5 thd.
23.0 deep min.
13,1
(.52)
26,2
(1.03)
See pilot flange options on page 101.
See shaft options starting on page 102.
82,3
(3.24)
82,3
(3.24)
93EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Thru-drive
Models
PVM057/063
Dimensions in millimeters (inches)
To mounting face
To mounting face
Right hand rotation with Load Sensing Control and
SAE 2-/4-bolt “B” adapter flange
“B” Adapter Flange
68,7
(2.70)
Coupling length
(see table)
Coupling (see table)
“R”
“V” Support
mounting point
(4 plcs)
35,0
(1.38)
(4 plcs)
“T2”
“T1”
92,0
(3.62)
309,9
(12.20)
297,4
(11.70)
“S”
Model Code Position 25
Description
A SAE “A,” 9T, 16/32 DP,
30° pressure angle,
involute spline
C SAE “B,” 13T, 16/32 DP,
30° pressure angle,
involute spline
D SAE “B-B,15T, 16/32 DP,
30° pressure angle,
involute spline
E SAE “C,14T, 12/24 DP,
30° pressure angle,
involute spline
G For ISO 80-A2HW pad
with a 9T SAE spline
J For ISO 100-A2/B4HW pad
with a 13T SAE spline
K For ISO 100-A2/B4HW pad
with a 15T SAE spline
L For ISO 125-A2/B4HW pad
with a 14T SAE spline
Coupling Length Code
SAE “A,” 9T 62,5 (2.46) A,G
SAE “B,” 13T 93,0 (3.66) C,J
SAE “B-B,” 15T 93,0 (3.66) D,K
SAE “C,” 14T 93,0 (3.66) E,L
Support
Model Code Position 25 Pilot Dia. Pilot Depth 2-bolt 4-bolt Mounting Points
Flange Bolt “R” “S” “T1” “T2” “V”
A,B SAE “A” 2-bolt SAE Ø82,65 (3.25±.001) 8,6/8,1 (.32/.34) .375-16 UNC-2B thd. N/A N/A
G,H ISO 80 ISO Ø80,05 (3.15) 9,0/8,0 (.35/.31) M10 thd. N/A N/A
C,D SAE “B” 2-/4-bolt SAE Ø101,65 (4.002±.001) 12,5/11,5 (.49/.45) .50-13 UNC-2B thd. .50-13 UNC-2B thd. .50-13 UNC-2B thd. .98” deep
J,K ISO 100 ISO Ø100,05 (3.94) 12,5/11,5 (.49/.45) M12 thd. M12 thd. M12 thd. x 25,0 deep
94 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Thru-drive
Models
PVM057/063
Support
Model Code Position 25 Pilot Dia. Pilot Depth 2-bolt 4-bolt Mounting Points
Flange Bolt “R” “S” “T1” “T2” “V”
E,F SAE “C” 2-/4-bolt SAE Ø127,05 (5.002±.001) 15,5/14,5 (.61/.57) .625-11 UNC-2B thd. .50-13 UNC-2B thd. .50-13 UNC-2B thd. .98” deep
L,M ISO 125 ISO Ø125,05 (4.92) 15,5/14,5 (.61/.57) M16 thd. M12 thd. M12 thd. x 25,0 deep
Dimensions in millimeters (inches)
“C” Adapter Flange
To mtg. face
To mtg, face
“W” (4 plcs)
35,0
(1.38)
(4 plcs)
“T2”
“T1”
92,0
(3.62)
Left hand rotation with Pressure Compensator and
SAE 2-/4-bolt “C” Adapter Flange
309,9
(12.20)
297,4
(11.70)
“R”
107,0
(4.21)
95EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Side-ported
Models
PVM074/081
*Right Hand Only
TO MOUNTING FACE
w/o max adj stop
Inlet port "B".
See options
on page 106.
Inlet gauge port
"K". See options
on page 107
.
Outlet gauge port
"K". See options
on page 107
.
Outlet port
"C". See
options
on page 106.
Load sense port "J".
See options on page 107
.
Drain port
"F". See
options on
page 107
.
C/G location
Inlet gauge
port "K".
See options
on page 107
.
Alt. drain port "F".
See options on page 107
.
Max. Adj. stop. One rotation will change
displacement 6,1-6,8 l/min
(1.6-1.8 USgpm) at 1800 rpm
Alt. drain port "F". See
options on page 107
.
Lifting point .375-16 UNC thd.
10,0 (.39) deep with SAE drain
M10 thd. 10,0 (.39) deep with ISO drain
Alt. drain port "F". See
options on page 107
.
Left hand rotation
with Pressure Compensator
Right hand rotation
with Load Sensing Control
Outlet
gauge
port "K".
See options
on page 107.
86,0
(3.39)
86,0
(3.39)
249,6
(9.83)
65,0
(2.56)
65,0
(2.56)
92,0
(3.62)
91,0
(3.58)
114,0
(4.49)
114,0
(4.49)
143,3
(5.64)
33,0
(1.30)
181,6
(7.15)
246,6
(9.71)
279,6
(11.01)
288,0
(11.34)
194,8
7.67
()
110,0
(4.33)
Outlet port
"C". See
options on
page 106
.
319,1
(12.56)
334,8
(13.18)
2X
87,0
(3.42)
33,9
(1.33)
113,6
(4.47)
102,0
(4.02)
4,3
(.17)
146,1
5.75
()
16,8
(.66)
Inlet port "B". See
options on page 106.
Dimensions in millimeters (inches)
See pilot flange options on page 101.
See shaft options starting on page 102.
PVM074/108 is not available with left hand rotation in any port configuration.
96 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Thru-drive
Models
PVM074/081
*Right-hand only
TO MOUNTING FACE
Alt. drain port
"F". See options
on page 107
.
Inlet gauge
port "K".
See options
on page 107.
Outlet gauge
port "K".
See options
on page 107
.
Load sense port "J".
See options on page 107
.
Drain port "F".
See options
on page 107.
w/o max adj stop
Alt. drain port "F". See
options on page 107
.
Lifting point .375-16 UNC thd.
10,0 (.39) deep with SAE drain
M10 thd. 10,0 (.39) deep with ISO drain
Alt. drain port "F". See
options on page 107
.
Inlet port "B".
See options
on page 106.
Inlet gauge port
"K". See options
on page 107
.
Outlet gauge port
"K". See options
on page 107
.
Outlet port "C".
See options on
page 106.
C/G location
Max. Adj. stop. One rotation will change
displacement 6,1-7,4 l/min
(1.7-1.9 USgpm) at 1800 rpm
2X T1
Dimensions in millimeters (inches)
See pilot flange options on page 101.
See shaft options starting on page 102.
249,6
(9.83)
92,0
(3.62)
91,0
(3.58)
114,0
(4.49)
114,0
(4.49)
143,3
(5.64)
33,0
(1.30)
181,6
(7.15)
246,6
(9.71)
194,8
(7.67)
110,0
(4.33)
Outlet port "C".
See options on
page 106
.
319,1
(12.56)
334,8
(13.18)
2X
87,0
(3.42)
33,9
(1.33)
113,6
(4.47)
102,0
(4.02)
4,08
(.16)
146,1
(5.75)
14.5
(0.57)
Inlet port "B". See
options on page 106
.
86,0
(3.39)
86,0
(3.39)
"A2" 45,0
(1.77)
322.6
(12.70)
277,6
(10.93)
Left hand rotation
with Pressure Compensator
Right hand rotation
with Load Sensing Control
and 2-bolt“A” flange
PVM074/108 is not available with left hand rotation in any port configuration.
97EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Thru-drive
Models
PVM074/081
*Right-hand only
“T1”
“T2”
To mtg, face
To mtg, face
View rotated 90°
4X “W”
“A1”
“A2”
92,0
(3.62)
“A1”
335,1
(13.19)
372,6
(14.68)
4X
35,0
(1.38)
Dimensions in millimeters (inches)
Right hand rotation with Load Sensing Control
and ISO or SAE 2-/4-bolt “B” adapter flange
“B” Adapter Flange
68,3
(2.69)
Coupling length
(See table)
25,0 (.98)
Coupling (see table)
“S”
“R3”
“R1”
“R2"
43,3
(1.70)
“S”
“R3”
“R1”“R2”
Coupling (see table)
Coupling length
(see table)
With adapter plateWithout adapter plate
Model code Position 25
Description
A SAE “A,” 9T, 16/32 DP,
30° pressure angle,
involute spline
B SAE “A,” 11T, 16/32 DP,
30° pressure angle,
involute spline
C SAE “B,” 13T, 16/32 DP,
30° pressure angle,
involute spline
D SAE “B-B,15T, 16/32 DP,
30° pressure angle,
involute spline
E SAE “C,14T, 12/24 DP,
30° pressure angle,
involute spline
F SAE “C-C,17T, 12/24 DP,
30° pressure angle,
involute spline
G For ISO 80-A2HW pad
with a 9T SAE spline
H For ISO 80-A2HW pad
with a 11 T SAE spline
J For ISO 100-A2/B4HW pad
with a 13T SAE spline
K For ISO 100-A2/B4HW pad
with a 15T SAE spline
L For ISO 125-A2/B4HW pad
with a 14T SAE spline
M For ISO 125-A2/B4HW pad
with a 17T SAE spline
Coupling Length
Code
SAE “A,” 9T 64,5 (2.54) A,G
SAE “A,” 11T 65,3 (2.57) B,H
SAE “B,” 13T 95,3 (3.75) C,J
SAE “B-B,” 15T 95,3 (3.75) D,K
SAE “C,” 14T 95,3 (3.75) E,L
SAE “C-C,” 17T 91,8 (3.61) F,M
Model Code Position 25 Pilot O-ring O-ring Pilot Support
Flange Bolt Dia. Dia. Depth Depth 2-bolt 4-bolt Mounting Points 4-bolt 2-bolt
“R1” “R2” “R3” “S” “T1” “T2” “W” “A1” “A2”
A,B SAE “A” SAE Ø82,6 Ø89,65 2,00 (.08) 9,0/8,0 375-16 UNC-2B thd. N/A N/A N/A 53,2
G,H
2-bolt (3.25) (3.53) 1,90 (.07)
(.35/.31)
ISO 80 ISO Ø80,05 Ø89,75 2,70 (.11) 9,0/8,0 M10 thd. N/A N/A N/A 54,5
(3.15) (3.53) 2,60 (.10) (.35/.31) (2.15)
C,D SAE “B” SAE Ø101,65 Ø108,05 2,00 (.08) 12,5/11,5 .50-13 UNC-2B thd. .50-13 UNC-2B thd. .50-13 UNC-2B 44,9 73,0
J,K 2-/4-bolt (4.00) (4.25) 1,90 (.07) (.49/.45) thd. .98” deep (1.77) (2.87)
ISO 100 ISO Ø100,05 Ø108,75 2,70 (.11) 12,5/11,5 M12 thd. M10 thd. M12 thd. 25,0 deep 44,19 70,0
(3.94) (4.28) 2,60 (.10) (.49/.45) (1.74) (2.76)
98 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
To mtg, face
To mtg, face
“T1”
“T2”
View rotated 90ϒ
4X “W”
92,0
(3.62)
“A1”
“A1”
“A2”
335,1
(13.19)
347,6
(13.69)
35,0
(1.38)
4X
Dimensions in millimeters (inches)
“C” Adapter Flange
Left hand rotation with Pressure Compensator
and ISO or SAE 2-/4-bolt “C” Adapter Flange
Thru-drive
Models
PVM074/081
*Right-hand only
Model Code Position 25 Pilot O-ring O-ring Pilot Support
Flange Bolt Dia. Dia. Depth Depth 2-bolt 4-bolt Mounting Points
“R1” “R2” “R3” “S” “T1” “T2” “W” “A1” “A2”
E,F SAE “C” SAE Ø127,05 Ø133,45 2,00 (.08) 15,5/14,5 .625-11 UNC-2B thd. .50-13 UNC-2B thd. .50-13 UNC-2B 57,25 90,5
L,M 2-/4-bolt thd. .98” deep (2.25) (3.56)
ISO 125 ISO Ø125,05 Ø133,75 2,70 (.11) 15,5/14,5 M16 thd. M12 thd. M12 thd. 25,0 deep 56,57 90,0
(4.92) (3.26) 2,60 (.10) (.61/.57) (2.23) (3.54)
99EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Side-ported
Models
PVM098/106
w/o max adj stop
To mounting face
C/G location
Drain port “F”. See
options on page 107.
Load sense port “J”.
See options on page 107.
Inlet gauge
port “K”.
See options
on page 107.
Outlet gauge
port “K”. See
options on
page 107.
Max. Adj. stop. One rotation will
change displacement 7,9-8,7 l/min
(2.1-2.3 USgpm) at 1800 rpm
Alt. drain port
“F”. See options
on page 107.
Alt. drain port “F”. See
options on page 107.
Lifting point .375-16 UNC thd.10,0 (.39) deep with
SAE drain M10 thd. 10,0 (.39) deep with ISO drain
Alt. drain port “F”. See options on page 107.
Outlet port
“C”. See options
on page 106.
Inlet port “B”.
See options
on page 106.
Outlet gauge port
“K”. See options
on page 107.
Inlet gauge
port “K”. See
options on
page 107.
Left hand rotation
with Pressure Compensator
Left hand rotation with Load Sensing Control
Dimensions in millimeters (inches)
See pilot flange options on page 101.
See shaft options starting on page 102.
214,6
(8.45)
107,5
(4.23)
2X 194,5
(7.66)
266,9
(10.51)
305,6
(12.03)
322,6
(12.70)
37,0
(1.46)
91,0
(3.58)
98,0
(3.86)
70,0
(2.76)
70,0
(2.76)
119,0
(4.69)
119,0
(4.69)
90,0
(3.54)
92,5
(3.64)
276,9
(10.90)
33,9
(1.33)
115,5
(4.55)
342,4
(13.48)
357,8
(14.09)
2X
95,0
(3.74)
162,0
(6.38)
170,6
(6.72)
Inlet port “B”. See
options on page 106.
155,7
(6.13)
35,5
(1.40)
Outlet port “C”. See
options on page 106.
16,4
(.65)
121,0
(4.76)
PVM098/106 is not available in left hand rotation with rear ports.
100 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Thru-drive
Models
PVM098/106
w/o max adj stop
Alt. drain port "F". See
options on page 107.
Lifting point .375-16 UNC thd. 10,0 (.39) deep with
SAE drain M10 thd. 10,0 (.39) deep with ISO drain
Alt. drain port "F". See options on page 107.
Inlet gauge port "K". See
options on page 107.
Outlet gauge port "K".
See options on page 107.
To mounting face
Max. Adj. stop. One rotation will change
displacement 7,9-8,7 l/min
(2.1-2.3 USgpm) at 1800 rpm
C/G location
Drain port "F".
See options
on page 107.
Alt. drain port "F". See
options on page 107.
Load sense port "J".
See options on page 107.
Outlet port
"C". See
options on
page 106.
Inlet port "B".
See options
on page 106.
Outlet gauge port
"K". See options
on page 107.
Inlet gauge port
"K". See options
on page 104.
2X T1
Dimensions in millimeters (inches)
See pilot flange options on page 101.
See shaft options starting on page 102.
Left hand rotation
with Pressure Compensator
Right hand rotation with 2-bolt “A” flange
and Load Sensing Control
214,6
(8.45)
107,5
(4.23)
2X 194,5
(7.66)
266,9
(10.51)
2X
37,0
(1.46)
91,0
(3.58)
98,0
(3.86)
119,0
(4.69)
119,0
(4.69)
90,0
(3.54)
92,5
(3.64)
276,9
(10.90)
33,9
(1.33)
115,5
(4.55)
342,4
(13.48)
357,8
(14.09)
2X
95,0
(3.74)
162,0
(6.38)
170,6
(6.72)
Inlet port "B". See
options on page 106.
164,4
(6.47)
36,6
(1.44)
Outlet port "C".
See options
on page 106.
17,3
(0.68)
121,0
(4.76)
45,0
(1.77)
A2*
42,0
(1.65)
150,0
(5.91)
347,9
(13.70)
PVM098/106 is not available in left hand rotation with rear ports.
101EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
“T1”
“T2”
92,0
(3.62)
“A1”
“A1”
“A2”
4X
35,0
(1.38)
360,4
(14.19)
372,6
(14.68)
To mtg, face
To mtg, face
4X “W” Support
mounting points
View Rotated 90°
Right hand rotation with Load Sensing Control
“B” Adaptor Flange
COMBINE WITH
EXISTING GRAPHIC
FOR THIS PAGE
Thru-drive
Models
PVM098/106
Dimensions in millimeters (inches)
View Rotated 90°
To mtg, face
To mtg, face
Right hand rotation with “CV” compensation
and ISO or SAE 2-/4-bolt “B” adapter flange
“B” Adapter Flange
68,3
(2.69)
Coupling length
(see table)
25,0
(.98)
Coupling (see table)
“S”
“R3”
“R1”
“R2”
43,3
(1.70)
“S”
“R3”
“R1”
“R2”
Coupling (see table)
Coupling length
(see table)
“V” Support
mounting
points (4 plcs)
35,0
(1.38)
(4 plcs)
“A2”
“A1”
“T2”
“T1”
92,0
(3.62)
“A1”
372,9
(14.68)
360,4
(14.19)
With adapter plate Without adapter plate
Coupling Length
Code
SAE “A,” 9T 64,5 (2.54) A,G
SAE “A,” 11T 65,3 (2.57) B,H
SAE “B,” 13T 95,3 (3.75) C,J
SAE “B-B,” 15T 95,3 (3.75) D,K
SAE “C,” 14T 95,3 (3.75) E,L
SAE “C-C,” 17T 91,8 (3.61) F,M
Model code Position 25
Description
A SAE “A,” 9T, 16/32 DP,
30° pressure angle,
involute spline
B SAE “A,” 11T, 16/32 DP,
30° pressure angle,
involute spline
C SAE “B,” 13T, 16/32 DP,
30° pressure angle,
involute spline
D SAE “B-B,15T, 16/32 DP,
30° pressure angle,
involute spline
E SAE “C,14T, 12/24 DP,
30° pressure angle,
involute spline
F SAE “C-C,17T, 12/24 DP,
30° pressure angle,
involute spline
G For ISO 80-A2HW pad
with a 9T SAE spline
H For ISO 80-A2HW pad
with a 11 T SAE spline
J For ISO 100-A2/B4HW pad
with a 13T SAE spline
K For ISO 100-A2/B4HW pad
with a 15T SAE spline
L For ISO 125-A2/B4HW pad
with a 14T SAE spline
M For ISO 125-A2/B4HW pad
with a 17T SAE spline
Model Code Position 25 Pilot O-ring O-ring Pilot Support
Flange Bolt Dia. Dia. Depth Depth 2-bolt 4-bolt Mounting Points 4-bolt 2-bolt
“R1” “R2” “R3” “S” “T1” “T2” “W” “A1” “A2”
A,B SAE “A” SAE Ø82,6 Ø89,65 2,00 (.08) 9,0/8,0 375-16 UNC-2B N/A N/A N/A 53,2
G,H
2-bolt (3.25) (3.53) 1,90 (.07)
(.35/.31) thd. 0.59 deep
ISO 80 ISO Ø80,05 Ø89,75 2,70 (.11) 9,0/8,0 M10 thd. N/A N/A N/A 54,5
(3.15) (3.53) 2,60 (.10) (.35/.31) x 18,0 deep (2.15)
C,D SAE “B” SAE Ø101,65 Ø108,05 2,00 (.08) 12,5/11,5 .50-13 UNC-2B thd. .50-13 UNC-2B thd. .50-13 UNC-2B 44,9 73,0
J,K 2-/4-bolt (4.00) (4.25) 1,90 (.07) (.49/.45) thd. .98” deep (1.77) (2.87)
ISO 100 ISO Ø100,05 Ø108,75 2,70 (.11) 12,5/11,5 M12 thd. M10 thd. M12 thd. 25,0 deep 44,19 70,0
(3.94) (4.28) 2,60 (.10) (.49/.45) (1.74) (2.76)
102 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Thru-drive
Models
PVM098/106
To mtg, face
To mtg, face
4X “W” Support
mounting points
View Rotated 90°
“T2”
“T1”
372,9
(14.68)
4X
35,0
(1.38)
360,4
(14.19)
“A1”
“A2”
“A1”
92,0
(3.62)
Dimensions in millimeters (inches)
“C” Adapter Flange
Left hand rotation with Pressure Compensator
and ISO or SAE 2-/4-bolt “C” adapter flange
Model Code Position 25 Pilot O-ring O-ring Pilot Support
Flange Bolt Dia. Dia. Depth Depth 2-bolt 4-bolt Mounting Points
“R1” “R2” “R3” “S” “T1” “T2” “W” “A1” “A2”
E,F SAE “C” SAE Ø127,05 Ø133,45 2,00 (.08) 15,5/14,5 .625-11 UNC-2B thd. .50-13 UNC-2B thd. .50-13 UNC-2B 57,25 90,5
L,M 2-/4-bolt thd. .98” deep (2.25) (3.56)
ISO 125 ISO Ø125,05 Ø133,75 2,70 (.11) 15,5/14,5 M16 thd. M12 thd. M12 thd. 25,0 deep 56,57 90,0
(4.92) (3.26) 2,60 (.10) (.61/.57) (2.23) (3.54)
103EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
End-ported
Models
PVM131/141
See pilot flange options on page 101.
See shaft options starting on page 102.
115,0
(4.53)
Dimensions in millimeters (inches)
111,5
(4.39)
2 plcs.
143,5 (5.65)
“F3”
192,6 (7.58)
2 plcs.
346,1 (13.63) max. length
w/o max. adj. stop
122,6 (4.83) 2 plcs.
“F” drain port
Lifting point
.500-13 UNC-2B thd.
18,0 (.709) dp. 2 plcs.
65,0 (2.56) 2 plcs.
55,0 (2.17) 2 plcs.
330,6 (13.02)
“K” Inlet
gage port
25,0
(0.98)
172,0
(6.77)
34,0
(1.34)
369,4 (14.54)
230,4 (9.07)
Optional drain port “F”
“F2”
“B2” 4 plcs.
“K” Inlet
gage port
“B” inlet
port
Right hand rotation with
Load Sensing Control
104,2
(4.10)
91,5
(3.60)
49,7 (1.95)
64,0
(2.52)
“J” Load sense signal port
132,7 (5.22)
110,5 (4.35) R.H.
94,5 (3.72) L.H.
“C2” 4 plcs.
“K” Outlet
gage port
“C” outlet
port
180,6 (7.11)
131,0
(5.16)
132,7
(5.22)
“C”
outlet
port
“K”
Outlet
gage
port
Lef t hand rotation
with Pressure Compensator
“B” inlet port
“K”
Inlet
gage
port
Adjustable maximum stop option.
Torque locknut to 37-45 Nm (27-33 lb ft).
One turn of screw wil change pump
displacement 5,7 cm
3
/rev (0.35 in
3
/rev).
Turn CCW to destroke.
106,0
(4.17)
55,0
(2.17)
Optional drain
port “F”
104 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Side-ported
Models
PVM131/141
See pilot flange options on page 101.
See shaft options starting on page 102.
“C2”
4 plcs.
“C”
outlet
port
Outlet gage
port “K”
70,0
(2.76)
346,1 (13.63) max. length
w/o max. adj. stop
143,5
(5.70)
Dimensions in millimeters (inches)
115,0
(4.53)
172,0
(6.77)
34,0
(1.34)
369,4 (14.54)
230,4 (9.07)
Optional drain port “F”
280,4 (11.04)
outlet
port
C
L
100,0 (3.94)
131,0
(5.16)
132,7
(5.22)
Left hand rotation with
Pressure Compensator
Inlet
port “B”
Inlet gage
port “K”
Outlet gage port “K”
Outlet port “C.”
111,5
(4.39)
2 plcs.
“F3”
122,6
(4.82)
2 plcs.
65,0 (2.56) 2 plcs.
55,0 (2.16) 2 plcs.
192,6 (7.58)
2 plcs.
298.6 (11.76)
“F” drain port
Lifting point
.500-13 UNC-2B thd.
18.0 (.709) dp. 2 plcs.
Inlet port “B”
“B2”
4 plcs.
180,6 (7.11)
“F2”
106,0
(4.17)
Right hand rotation with
Load Sensing Control
95.0
(3.74)
70,0
(2.76)
“J” Load sense signal port
132,7 (5.22)
110,5 (4.35) R.H.
94,5 (3.72) L.H.
Optional drain
port “F”
Inlet gage
port “K”
A
A
View A - A Outlet port
280,4
(11.04)
ref.
318,1 (12.52)
gage port spotface
341,1 (13.43)
gage port spotface
Adjustable maximum stop option.
Torque locknut to 37-45 Nm (27-33 lb ft).
One turn of screw will change pump
displacement 5,7 cm
3
/rev (0.35 in
3
/rev)
55,0
(2.17)
105EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Thru-drive
Models
PVM131/141
See pilot flange options on page 101.
See shaft options starting on page 102.
369,4
(14.54)
346,1
(13.63)
w/o max.
adj. stop
122,6
(4.83)
L
e
ft
H
a
nd
R
o
t
a
t
ion
with Pressure Compensator
and SAE 2-bolt “A” Flange (no adapter)
R
igh
t
H
a
nd
R
o
t
a
t
ion
with Load Sensing Control
and SAE 2-bolt “A” Flange (no adapter)
173,0
(6.81)
192,6
(7.58)
298,6
(11.76)
“Q” See table below
65,0
(2.56)
55,0
(2.17)
305,6
(12.03)
143,5
(5.65)
SAE port 116,1 (4.57)
ISO port 150,0 (5.91)
Inlet gage port “K”
54,5
(2.15)
15,0
(.59)
Inlet port “B.” See
options on page 106.
SAE .500-13 UNC-2B
thd. 1.19 deep min. or
ISO M12 x 31.0 deep min.
SAE .500-13 UNC-2B
thd. 1.00 deep min. or
ISO M12 x 27.0 deep min.
180,6
(7.11)
111,5
(4.39)
106,0
(4.17)
55,0
(2.16)
11,5
(.45)
100,0
(3.94)
SAE port 116,1 (4.57)
ISO port 150,0 (5.91)
95,0
(3.74)
40,0
(1.57)
4,0
(.16)
Inlet gage
port “K.” See
options on page 107.
Outlet gage port “K.” See
options on page 107.
Alt. drain port “F.” See
options on page 107.
Load sense port “J.”
See options on
page 107.
132,7
(5.22)
313,6
(12.35)
280,4
(11.04)
45,0
(1.77)
Outlet port “C.”
See options on
page 106.
“Q2” See
table below
Outlet port “C.”
See options on
page 106.
Inlet port “B.”
See options on
page 106.
132,7
(5.22)
131,0
(5.16)
Drain port “F.” See options
on page 107.
172,0
(6.77)
347,1
(13.67)
230,4
(9.07)
80,0
(3.15)
44,7
(1.76)
8,5 (.33)
14,0 (.55) A9
19,0 (.75) A11
See coupling
code below
See output
shaft below
Dimensions in millimeters (inches)
34,0
(1.33)
280,4
(11.04)
outlet
port
C
L
Model Code Position 25 “Q1” Thru-drive Flange “Q2” 2-bolt Thread
A,B SAE J744-82-2 .375-16 UNC-2B
Ø82.625/82.575 bore thd. 0.80 deep
G,H ISO 3019/2-80A2
M10 thd. x 18,0 deep
Ø80.075/80.25 bore
106 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Thru-drive
Models
PVM131/141
Right Hand Rotation with SAE 2-/4-Bolt “B”
Flange and ISO 100 Adapter Flange
372,1 (14.65)
359,6 (14.16)
35,0 (1.38)
4 places
“R2” - 2 places
“R3”
4 places
“R1”
92,0 (3.62) 4 places
69,7 (2.74)
14,0 (.55)
O-ring (furnished)
Coupling (See table)
Dimensions in millimeters (inches)
“B” Adapter Flange
“R4” (4 plcs)
Model Code Position 25
Description
A For SAE “A” pad with a 9T, 16/32 DP, 30° pressure
angle,
involute spline
B For SAE “A” pad with a 11T, 16/32 DP, 30° pressure
angle,
involute spline
Output shaft 14T 12/24 DP external involute spline
C SAE “B,” 13T, 16/32 DP, 30° pressure angle, involute
spline
D SAE “B-B,” 15T, 16/32 DP, 30° pressure angle, invo-
lute spline
E SAE “C,” 14T, 12/24 DP, 30° pressure angle, involute
spline
F SAE “C-C,” 17T, 12/24 DP, 30° pressure angle, invo-
lute spline
G For ISO 80-A2HW pad with a 9T SAE spline
H For ISO 80-A2HW pad with a 11T SAE spline
J For ISO 100-A2/B4HW pad with a 13T SAE spline
K For ISO 100-A2/B4HW pad with a 15T SAE spline
L For ISO 125-A2/B4HW pad with a 14T SAE spline
M For ISO 125-A2/B4HW pad with a 17T SAE spline
Model Code
Position 25 “R1” Thru-drive Flange “R2” 2-bolt Thread “R3” 4-bolt Thread “R4” Support Mounting Points
C,D SAE J744-101-2 & -4 .500-13 UNC-2B .500-13 UNC-2B .500-13 UNC-2B
Ø101,675/101.625 bore 12,50/11,50 deep 0.98 deep 0.98 deep 0.98 deep
J,K ISO 3019/2-100A2 & B2 M12 M12 M12
Ø100,075/100.025 bore 12,50/11,50 deep 25,0 deep 25,0 deep 25,0 deep
107EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Thru-drive
Models
PVM131/141
359,6 (14.16)
372,1 (14.65)
“S4” 4 places
35,0 (1.38)
4 places
92,0 (3.62) 4 places
“S1”
“S2”
2 places
“S3”
4 places
Left Hand Rotation with SAE 2-/4-bolt “C”
and ISO 125 Adapter Flange
Dimensions in millimeters (inches)
“C” Adapter Flange
Model Code
Position 25 “S1” Thru-drive Flange “S2” 2-bolt Thread “S3” 4-bolt Thread “R4” Support Mounting Points
E,F SAE J744-127-2 & -4 .625-11 UNC-2B .500-13 UNC-2B .500-13 UNC-2B
Ø127,075/127.025 bore 15,50/14,50 deep 0.98 deep 0.98 deep 0.98 deep
L,M ISO 3019/2-125A2 & B4 M16 M12 M12
Ø125,075/125.025 bore 15,50/14,50 deep 25,0 deep 25,0 deep 25,0 deep
Port “B”* “B2” “C”* “C2” “F2” “F3”
SAE
2.50 inch dia. SAE J518 .500-13 UNC-2B thd. 1.25 inch dia. SAE J518 .500-13 UNC-2B thd. 146,8 114,9
Code 61, low pressure 1.19 deep minimum Code 62, high pressure 1.00 deep minimum (5.78) (4.52)
ISO
64mm diameter. ISO M12 thread 32mm diameter. M12 thread 148,5 116,6
6162 Type II, 315 bar 31,0 deep minimum ISO 6162, 400 bar 27,0 deep minimum (5.85) (4.59)
*4-bolt flange port. See page 101 for load sensing, drain, and gage port threads.
108 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Mounting Flange
Options
A
J pilot
E
F
G
H
G
H
J pilot
A
45°
K
K
L
L
Dimensions in millimeters (inches)
2-bolt “A, B & C” Flange
ISO & SAE
2-bolt “B” Flange
4-bolt “C” or “D” Flange
ISO & SAE
2-bolt or 4-bolt
Series Flange Code Flange Description A E F G H J K L
PVM018
2-bolt
A SAE J744-82-2 Ø11,14 53,2
106,4
Ø82,53 +.02
-.03
PVM020
“A” (4.38) (2.09) (4.19)
(Ø3.249) +.000
-.001
PVM018
2-bolt
B ISO 3019/2-80A2HW Ø11,14 54,5
109,0
Ø79,98 +.02
-.03
PVM020
“A” (4.38) (2.15) (4.29)
(Ø3.15) +.000
-.001
PVM018
PVM020
PVM045 2-bolt C SAE J744-101-2 14,36 73,0 146,0 Ø101,58 +.02
PVM050 “B” -.03
PVM057 (.565) (2.87) (5.75) _ (Ø3.999) ±.001
PVM063
PVM018
PVM020
PVM045 2-bolt D ISO 3019/2-100A2HW 14,14 70,0 140,0 Ø100,00/99,95
PVM050 “B” (special) (.557) (2.76) (5.51) (Ø3.937/3.935)
PVM057
PVM063
PVM057
E SAE J744-127-2 (“C”) 17,4 90,5 181,0 Ø127,00/126,95
PVM063
2-bolt
(.685) (3.562) (7.125) (Ø5.000/4.998)
PVM074
“C”
F ISO 3019/2-125A2HW 18,0 90,0 180,0 Ø125,00/124,95
PVM081
(.709) (3.543) (7.09) (Ø4.921/4.919)
PVM098
G SAE J744-127-4 (“C”) 14,2
57,25 114,50 Ø127,00/126,95
PVM106
4-bolt
(.559) (2.254) (4.508) (Ø5.000/4.998)
PVM131
“C”
H ISO 3019/2-125B4HW 14,0
Ø125,00/124,95 80,0 160,0
PVM141
(.551) (Ø4.921/4.919) (3.150) (6.299)
J SAE J744-152-4 (“D”) 20,6
80,82 161,64 Ø152,40/152,35
PVM131
4-bolt
(.812) (3.182) (6.364) (Ø6.000/5.998)
PVM141
“D”
K ISO 3019/2-160B4HW 18,0
Ø160,00/159,95 100,0 200,0
(.709) (Ø6.299/6.297) (3.937) (7.874)
*Flanges for PVM020 and PVM050 are shown on pages 73 and 80, respectively.
109EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Shaft Options
B spline
C
D
Dimensions in millimeters (inches)
SAE Splined Shaft
A
SAE Spline Shaft Max. Input Torque
Model Series Designation Shaft Code A max. B C D Nm (lb. in.)
SAE J744-16-4
03 15,88 (.625) 9T 16/32 DP 37,0 (1.46) 32,0 (1.26) 58 (517)
SAE “A” (9T)
SAE J744-19-4
04 19,05 (.750) 11T 16/32 DP 30,0 (1.18) 38,0 (1.50) 123 (1100)
PVM018/020
SAE “A” (11T)
SAE J744-22-4
07 21,81 (.859) 13T 16/32 DP 33,0 (1.31) 41,0 (1.61) 208 (1850)
SAE “B” (13T)
SAE J744-25-4
08 24,98 (.983) 15T 16/32 DP 38,0 (1.50) 46,0 (1.81) 337 (2987)
SAE “B-B” (15T)
SAE J744-22-4
07 21,81 (.859) 13T 16/32 DP 33,0 (1.31) 41,0 (1.61) 208 (1850)
PVM045/050
SAE “B” (13T)
SAE J744-25-4
08 24,98 (.983) 15T 16/32 DP 38,0 (1.50) 46,0 (1.81) 337 (2987)
SAE “B-B” (15T)
SAE J744-22-4
07 21,81 (.859) 13T 16/32 DP 33,0 (1.31) 41,0 (1.61) 208 (1850)
SAE “B” (13T)
PVM057/063
SAE J744-25-4
08 24,98 (.983) 15T 16/32 DP 38,0 (1.50) 46,0 (1.81) 337 (2987)
SAE “B-B” (15T)
SAE J744-32-4
11 31,22 (1.23) 14T 12/24 DP 48,0 (1.89) 56,0 (2.20) 640 (5660)
SAE “C” (14T)
SAE J744-32-4
11 31,22 (1.23) 14T 12/24 DP 48,0 (1.89) 56,0 (2.20) 640 (5660)
PVM074/081
SAE “C” (14T)
PVM098/106 SAE J744-38-4
12 37,57 (1.479) 17T 12/24 DP 54,0 (2.13) 62,0 (2.44) 1215 (10,750)
SAE “C-C” (17T)
SAE J744-32-4
11 31,22 (1.23) 14T 12/24 DP 48,0 (1.89) 56,0 (2.20) 640 (5660)
SAE “C” (14T)
PVM131/141
SAE J744-38-4
12 37,57 (1.479) 17T 12/24 DP 54,0 (2.13) 62,0 (2.44) 1215 (10,750)
SAE “C-C” (17T)
SAE J744-44-4
14 43,71 (1.721) 13T 8/16 DP 67,0 (2.63) 75,0 (2.95) 1215 (10,750)
SAE “D” (13T)
110 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Shaft Options
Dimensions in millimeters (inches)
D
C
B
A
SAE Keyed Shaft
E key
Max. Input
SAE Keyed Shaft Shaft Torque
Model Series Designation Code A B C D E Nm (lb. in.)
SAE J744-16-1
01 15,88 (.625) 17,73 (.698) 24,0 (.94) 32,0 (1.26) 4,0 (.157)
58
SAE “A” (517)
SAE J744-19-1
02 19,05 (.750) 21,23 (.836) 24,0 (.94) 32,0 (1.26) 4,81 (.189)
104
PVM018/020
SAE “19-1” (918)
SAE J744-22-1
05 22,22 (.875) 25,12 (.989) 33,0 (1.31) 41,0 (1.61) 6,35 (.250)
135
SAE “B” (1200)
SAE J744-25-1
06 25,37 (.999) 28,22 (1.111) 38,0 (1.50) 46,0 (1.81) 6,35 (.250)
215
SAE “B-B” (1900)
SAE J744-22-1
05 22,22 (.875) 25,12 (.989) 33,0 (1.31) 41,0 (1.61) 6,35 (.250)
135
PVM045/050
SAE “B” (1200)
SAE J744-25-1
06 25,37 (.999) 28,22 (1.111) 38,0 (1.50) 46,0 (1.81) 6,35 (.250)
215
SAE “B-B” (1900)
SAE J744-25-1
06 25,37 (.999) 28,22 (1.111) 38,0 (1.50) 46,0 (1.81) 6,35 (.250)
215
PVM057/063
SAE “B-B” (1900)
SAE J744-32-1
09 31,75 (1.25) 35,32 (1.390) 48,0 (1.89) 56,0 (2.20) 7,93 (.312)
450
SAE “C” (3980)
SAE J744-32-1
09 31,75 (1.25) 35,32 (1.390) 48,0 (1.89) 56,0 (2.20) 7,93 (.312)
450
PVM074/081
SAE “C” (3980)
PVM098/106 SAE J744-38-1
10 38,10 (1.50) 42,39 (1.67) 54,0 (2.13) 62,0 (2.44) 9,52 (.375)
765
SAE “C-C” (6770)
SAE J744-32-1
09 31,75 (1.25) 35,32 (1.390) 48,0 (1.89) 56,0 (2.20) 7,93 (.312)
450
SAE “C” (3980)
PVM131/141
SAE J744-38-1
10 38,10 (1.50) 42,39 (1.67) 54,0 (2.13) 62,0 (2.44) 9,52 (.375)
765
SAE “C-C” (6770)
SAE J744-44-1
13 44,45 (1.75) 49,46 (1.95) 67,0 (2.63) 75,0 (2.95) 11,11 (.438)
1200
SAE “D” (10,620)
111EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Dimensions in millimeters (inches)
C
A
B
E
ISO Keyed Shaft
D key
Shaft Options
Max. Input
ISO Keyed Shaft Shaft Torque
Model Series Designation Code A B C D E Nm (lb. in.)
ISO 3019/2 E20N 15 19,9 (.786) 8,5 (.335) 36 (1.42) 6 (.236) 22,5 (.886) 113 (1000)
PVM018/020
ISO 3019/2 E25N
Short Spigot 16 25 (.984) 8,5 (.335) 42 (1.65) 8 (.315) 28,0 (1.102) 215 (1900)
ISO 3019/2 E25N 17 25 (.984) 10 (.393) 42 (1.65) 8 (.315) 28,0 (1.102) 215 (1900)
PVM045/050 ISO 3019/2 E25N 17 25 (.984) 10 (.393) 42 (1.65) 8 (.315) 28,0 (1.102) 215 (1900)
PVM057/063 ISO 3019/2 E25N 17 25 (.984) 10 (.393) 42 (1.65) 8 (.315) 28,0 (1.102) 215 (1900)
ISO 3019/2 E32N 18 32 (1.26) 10 (.393) 58 (2.28) 10 (.394) 35,0 (1.378) 450 (3980)
PVM074/081 ISO 3019/2 E32N 18 32 (1.26) 10,5 (.413) 58 (2.28) 10 (.394) 35,0 (1.378) 450 (3980)
PVM098/106 ISO 3019/2 E40N 19 40 (1.57) 10,5 (.413) 82 (3.23) 12 (.472) 43,0 (1.693) 870 (7700)
PVM131/141 ISO 3019/2 E32N 18 32 (1.26) 10 (.393) 58 (2.28) 10 (.394) 35,0 (1.378) 450 (3980)
ISO 3019/2 E40N 19 40 (1.57) 10 (.393) 82 (3.23) 12 (.472) 43,0 (1.693) 870 (7700)
(1)
ISO 80mm pilot only – B
(2)
ISO 80mm pilot only – D
*Torque of non-thru-drive PVM pump, or combined torque of PVM thru-drive pump and thru-driven pump.
NOTE: In those cases where geometric tolerances of mounting are critical, or where specific tolerance ranges are required and not specified,
consult Eaton Engineering for specific limits.
112 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Input Shaft
Selection Data
SAE Splined Shafts
Max. Input Torque† Max. Thru-drive Output Torque‡
Model Series Shaft Designation Shaft Code Nm (lb. in.) Nm (lb. in.)
SAE J744-16-4 (SAE “A,” 9T) 03 58 (513) Exceeds maximum input torque
PVM018/020
SAE J744-19-4 (SAE “A,” 11T) 04 123 (1100) Exceeds maximum input torque
SAE J744-22-4 (SAE “B,” 13T) 07 208 (1850) 123 (1100)
SAE J744-25-4 (SAE “B-B,” 15T) 08 337 (2987) 123 (1100)
PVM045/050
SAE J744-22-4 (SAE “B,” 13T) 07 208 (1850) 208 (1850)*
SAE J744-25-4 (SAE “B-B,” 15T) 08 337 (2987) 337 (2987)
SAE J744-22-4 (SAE “B,” 13T) 07 208 (1850) 208 (1850)*
PVM057/063 SAE J744-25-4 (SAE “B-B,” 15T) 08 337 (2987) 337 (2987)
SAE J744-32-4 (SAE “C,” 14T) 11 640 (5660) 337 (2987)
PVM074/081
SAE J744-32-4 (SAE “C,” 14T) 11 640 (5660) 515 (4560)
PVM098/106
SAE J744-38-4 (SAE “C-C,” 17T) 12 1215 (10,750) 515 (4560)
SAE J744-32-4 (SAE “C,” 14T) 11 640 (5660) 640 (5660)
PVM131/141 SAE J744-38-4 (SAE “C-C,” 17T) 12 1215 (10,750) 640 (5660)
SAE J744-44-4 (SAE “D,” 13T) 14 1215 (10,750) 640 (5660)
SAE Keyed Shafts
Max. Input Torque† Max. Thru-drive Output Torque‡
Model Series Shaft Designation Shaft Code Nm (lb. in.) Nm (lb. in.)
SAE J744-16-1 (SAE “A”) 01 58 (513) Exceeds maximum input torque
PVM018/020
SAE J744-19-1 (SAE “19-1”) 02 104 (920) Exceeds maximum input torque
SAE J744-22-1 (SAE “B”) 05 135 (1200) 123 (1100)
SAE J744-25-1 (SAE “B-B”) 06 215 (1900) 123 (1100)
PVM045/050
SAE J744-22-1 (SAE “B”) 05 135 (1200) 135 (1200)*
SAE J744-25-1 (SAE “B-B”) 06 215 (1900) 215 (1900)*
PVM057/063
SAE J744-25-1 (SAE “B-B”) 06 215 (1900) 215 (1900)*
SAE J744-32-1 (SAE “C”) 09 450 (3980) 337 (2987)
PVM074/081 SAE J744-32-1 (SAE “C”) 09 450 (3980) 450 (3980)*
PVM098/106 SAE J744-38-1 (SAE “C-C”) 10 765 (6770) 515 (4560)
SAE J744-32-1 (SAE “C”) 09 450 (3980) 450 (3980)*
PVM131/141 SAE J744-38-1 (SAE “C-C”) 10 765 (6770) 640 (5660)
SAE J744-44-1 (SAE “D”) 13 1200 (10,620) 640 (5660)
ISO Keyed Shafts
Max. Input Torque† Max. Thru-drive Output Torque‡
Model Series Shaft Designation Shaft Code Nm (lb. in.) Nm (lb. in.)
ISO 3019/2 E20N (B mount only) 15 113 (1000) Exceeds maximum input torque
PVM018/020 ISO 3019/2 E25N (B mount only) 16 215 (1900) Exceeds maximum input torque
ISO 3019/2 E25N (D mount only) 17 215 (1900) 123 (1100)
PVM045/050 ISO 3019/2 E25N 17 215 (1900) 215 (1900)*
PVM057/063
ISO 3019/2 E25N 17 215 (1900) 215 (1900)*
ISO 3019/2 E32N 18 450 (3980) 337 (2987)
PVM074/081
ISO 3019/2 E32N 18 450 (3980) 450 (3980)*
PVM098/106
ISO 3019/2 E40N 19 870 (7700) 515 (4560)
PVM131/141
ISO 3019/2 E32N 18 450 (3980) 450 (3980)*
ISO 3019/2 E40N 19 870 (7700) 640 (5660)
†Maximum total torque of the thru-drive pump and the thru-driven pump(s).
‡Maximum torque that can be applied to the thru-driven pump(s).
*This value is limited by the maximum input torque.
113EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Port Options
Inlet and Outlet Ports
Inlet/Outlet Port Option Port
Model Series (per model code, page 5) Code Inlet Port “B” Outlet Port “C”
Inch Flange 02
SAE J518 Code 61, standard pressure. SAE J518 Code 61, standard pressure.
1.25 inch diameter, .4375-14 x 1.12 bolt holes 0.75 inches diameter, .375-16 x .88 bolt holes
Metric Flange 04
ISO 6162 Type II, 315 bar. ISO 6162 Type II, 315 bar.
PVM018/020 31,75mm diameter, M10 x 28 bolt holes 19,05mm diameter, M10 x 22 bolt holes
Inch Tube 01 SAE J514 O-ring –20, for 1-1/4 inch O.D. tube SAE J514 O-ring -12, for 3/4 inch O.D. tube
Metric Tube 03 ISO 6149-1, M42 thread ISO 6149-1, M27 thread
British Parallel Pipe 05 ISO 228-1:1994 (E), G 1-1/4 thread ISO 228-1:1994 (E), G 3/4 thread
Inch Flange 02
SAE J518 Code 61, standard pressure. SAE J518 Code 61, standard pressure.
2.00 inch diameter, .500-13 x 1.06 bolt holes 1.00 inch diameter, .375-16 x .87 bolt holes
Metric Flange 04
ISO 6162 Type II, 315 bar. ISO 6162 Type II, 315 bar.
PVM045/050 51mm diameter, M12 x 27 bolt holes 25mm diameter, M10 x 22 bolt holes
Inch Tube 01 SAE J514 O-ring -24, for 1-1/2 inch O.D. tube SAE J514 O-ring -16, for 1 inch O.D. tube
Metric Tube 03 ISO 6149-1, M48 thread ISO 6149-1, M33 thread
British Parallel Pipe 05 ISO 228-1:1994 (E), G 1-1/2 thread ISO 228-1:1994 (E), G1 thread
Inch Flange 02
SAE J518 Code 61, standard pressure. SAE J518 Code 61, standard pressure.
2.00 inch diameter, .500-13 x 1.06 bolt holes 1.00 inch diameter, .375-16 x .88 bolt holes
Metric Flange 04
ISO 6162 Type II, 350 bar. ISO 6162 Type, 350 bar.
PVM057/063
51mm diameter, M12 x 29 bolt holes 25mm diameter, M10 x 23 bolt holes
Inch Tube 01 SAE J514 O-ring -24, SAE J514 O-ring
(End ported models only) for 1-1/2 inch O.D. tube -16 for 1 inch O.D. tube
Metric Tube
03 ISO 6149-1, M48 thread ISO 6149–1, M33 thread
(End ported models only)
Inch Flange 02
SAE J518 Code 61, standard pressure. SAE J518 Code 61, standard pressure.
PVM074/081
2.00 inch diameter, .500-13 x 1.19 bolt holes 1.00 inch diameter, .375 -16 x .88 bolt holes
Metric Flange 04
ISO 6162 Type II, 315 bar. ISO 6162 Type, 400 bar.
51mm diameter, M12 x 20 bolt holes 25mm diameter, M10 x 17 bolt holes
Inch Flange 02
SAE J518 Code 61, standard pressure. SAE J518 Code 61, standard pressure.
PVM098/106
2.50 inch diameter, .500-13 x 1.19 bolt holes 1.00 inch diameter, .375 -16 x .88 bolt holes
Metric Flange 04
ISO 6162 Type I, 350 bar. ISO 6162 Type I, 350 bar.
64mm diameter, M12 x 31 bolt holes 25mm diameter, M10 x 23 bolt holes
Inch Flange 02
SAE J518 Code 61, standard pressure. SAE J518 Code 62, high pressure.
PVM131/141
2.50 inch diameter, .500-13 x 1.19 bolt holes 1.25 inch diameter, .500 -13 x 1.00 bolt holes
Metric Flange 04
ISO 6162 Type II, 315 bar. ISO 6162 Type, 400 bar.
64mm diameter, M12 x 31 bolt holes 32mm diameter, M12 x 27 bolt holes
Port Options
Drain, Load Sensing, and Gauge Ports
Inlet/Outlet Port Option Port
Model Series (per model code, page 5) Code Drain Port “F” Load Sensing Port “J” Gauge Port “K”
Inch Flange or Tube 01, 03 SAE J514 O-ring, .50’’ O.D. SAE J514 O-ring, .25’’ O.D. SAE J514 O-ring, .25’tube.
tube. .750-16 UNF 2B thread tube. .4375-20 UNF 2B thread .4375-20 UNF 2B thread
PVM018/020
Metric Flange or Tube 03, 04 ISO 6149-1 O-ring ISO 6149-1 O-ring ISO 6149-1 O-ring
M18 x 1,5 thread M12 x 1,5 thread M12 x 1,5 thread
British Parallel Pipe 05 ISO 228-1:1994 (E) ISO 228-1:1994 (E) ISO 228-1:1994 (E)
G 1/2 thread G 1/4 thread G 1/4 thread
Inch Flange or Tube 01, 03 SAE J514 O-ring, .625’’ O.D. SAE J514 O-ring, .250’O.D. SAE J514 O-ring, .375’ O.D. tube.
tube. .875-14 UNF 2B thread tube. .4375-20 UNF 2B thread .5625-18 UNF 2B thread
PVM045/050
Metric Flange or Tube 03, 04 ISO 6149-1 O-ring ISO 6149-1 O-ring ISO 6149-1 O-ring
M22 x 1,5 thread M12 x 1,5 thread M14 x 1,5 thread
British Parallel Pipe 05 ISO 228-1:1994 (E) ISO 228-1:1994 (E) ISO 228-1:1994 (E)
G 1/2 thread G 1/4 thread G 1/4 thread
Inch Flange or Tube 01, 02 SAE J514 O-ring, .625’’ O.D. SAE J514 O-ring, .375’O.D. SAE J514 O-ring, .375’ O.D. tube.
PVM057/063
tube. .875-14 UNF 2B thread tube. .5625-18 UNF 2B thread .5625-18 UNF 2B thread
Metric Flange or Tube 03, 04 ISO 6149-1 O-ring ISO 6149-1 O-ring ISO 6149-1 O-ring
M22 x 1,5 thread M14 x 1,5 thread M14 x 1,5 thread
Inch Flange 02 SAE J514 O-ring, .625’O.D. SAE J514 O-ring, .375’’ O.D. SAE J514 O-ring, .375’ O.D. tube.
PVM074/83
tube. .875-14 UNF 2B thread tube. .562-18 UNF 2B thread .5625-18 UNF 2B thread
PVM098/106
Metric Flange 04 ISO 6149-1 O-ring ISO 6149-1 O-ring ISO 6149-1 O-ring
M22 x 1,5 thread M14 x 1,5 thread M14 x 1,5 thread
Inch Flange 02 SAE J514 O-ring, .625’O.D. SAE J514 O-ring, .375’’ O.D. SAE J514 O-ring, .375’ O.D. tube.
PVM131/141
tube. .875-14 UNF 2B thread tube. .562-18 UNF 2B thread .5625-18 UNF 2B thread
Metric Flange 04 ISO 6149-1 O-ring ISO 6149-1 O-ring ISO 6149-1 O-ring
M22 x 1,5 thread M14 x 1,5 thread M14 x 1,5 thread
Operating
Requirements
Inlet Pressure, case pressure, and operating temperature requirements
Inlet Pressure Case Pressure Operating Temperature
Rated Minimum Maximum Maximum Maximum Maximum
Absolute bar, absolute Gauge Continuous Intermittent Peak Rated Intermittent
bar (psi) (in. Hg) bar (psi) bar (psi) bar (psi) bar (psi) °C (°F) °C (°F)
1,0 (14.5) 0,85 (5) 3,5 (50) 0,5 (7) 2 (30) 3,5 (50) 82 (180) 104 (220)
Hydraulic Fluids
Minimum Viscosity @ Max.
Recommended Operating Maximum Viscosity Intermittent Temperature of
Viscosity Range at Startup 104°C (220°F)
Fluid cSt (SUS) cSt (SUS) cSt (SUS)
Use antiwear hydraulic oil, or automotive
type crankcase oil (designations SC, SD, SE, 16 to 40 (83 to 187) 1000 (4550) 10 (90)
or SF) per SAE J183 FEB80
For more information, see Eaton publication 579. For operation on other alternative or environmentally friendly fluids, please contact your Eaton Representative.
Fluid Cleanliness
The M Series pumps are rated
in anti-wear petroleum uids
with a contamination level of
20/18/13 (Eaton) or ISO 18/13.
Operation in uids with levels
more contaminated than this is
not recommended. Fluids other
than petroleum, severe service
cycles, or temperature extremes
are cause for adjustment of
these codes. Please contact
your Eaton Representative
for specific duty cycle recom-
mendation.
Eaton M Series pumps, as
with any variable displacement
piston pumps, will operate with
apparent satisfaction in uids
up to the rating specified here.
Experience has shown, how-
ever, that pump and hydraulic
system life is not optimized with
high uid contamination levels
(high ISO cleanliness codes).
Proper uid condition is
essential for long and satisfac-
tory life of hydraulic components
and systems. Hydraulic uid
must have the correct balance
of cleanliness, materials, and
additives for protection against
wear of components, elevated
viscosity and inclusion of air.
Essential information on the
correct methods for treating
hydraulic uid is included in
Eaton publication 561
“Eaton Guide to Systemic
Contamination Control”
Available from your local Eaton
distributor. In this publication,
filtration and cleanliness levels
for extending the life of axial
piston pumps and other system
components are listed. Included
is an excellent discussion of the
selection of products needed to
control uid condition.
Moment of Inertia (single pump rotating group)
Model Moment of Inertia
N-m (sec
2
) lbf-in (sec
2
)
PVM018 0.0012 0.0104
PVM020 0.0012 0.0104
PVM045 0.0036 0.0320
PVM050 0.0034 0.0300
PVM057 0.0052 0.0457
PVM063 0.0051 0.0447
PVM074 0.0078 0.0691
PVM081 0.0073 0.0643
PVM098 0.0132 0.1165
PVM106 0.0123 0.1086
PVM131 0.0213 0.1889
PVM141 0.0210 0.1856
116 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
Installation and
Start-up
Warning: Care should be taken
that mechanical and hydraulic
resonances are avoided in the
application of the pump. Such
resonances can seriously
compromise the life and/or safe
operation of the pump.
Drive Data
Mounting attitude can be either
horizontal or vertical, using the
appropriate case drain ports to
ensure that the case remains
full of uid at all times. Consult
your local Eaton Representative
if a different arrangement is
required.
In those cases where geomet-
ric tolerances of mounting are
critical, or where specific toler-
ance ranges are required and
not specified, consult Eaton
Engineering for specific limits.
Direction of shaft rotation,
viewed from the prime mover
end, must be as indicated in
the model designation on the
pump either right hand
(clockwise) or left hand (counter-
clockwise).
Direct coaxial drive through
a exible coupling is recom-
mended. If drives imposing
radial shaft loads are considered,
please consult your Eaton
Representative.
Start-up Procedure
Make sure the reservoir and
circuit are clean and free of
dirt/debris prior to filling with
hydraulic uid.
Fill the reservoir with filtered
oil and fill to a level sufficient
enough to prevent vortexing at
the suction connection to pump
inlet. It is good practice to
clean the system by ushing
and filtering, using an external
slave pump.
Caution: Before the pump is
started, fill the case through
the uppermost drain port with
hydraulic uid of the type to be
used. The case drain line must
be connected directly to the res-
ervoir and must terminate below
the oil level.
Once the pump is started,
it should prime within a few
seconds. If the pump does not
prime, check to make sure
that there are no restrictions
between the reservoir and the
inlet to the pump, that the pump
is being rotated in the proper
direction, and that there are no
air leaks in the inlet line and con-
nections. Also check to make
sure that trapped air can escape
at the pump outlet.
After the pump is primed,
tighten the loose outlet con-
nections, then operate for five
to ten minutes (unloaded) to
remove all trapped air from
the circuit.
If the reservoir has a sight gage,
make sure the uid is clear
not milky.
117EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
This page intentionally blank.
118 EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
This page intentionally blank.
119EATON Vickers PVM Industrial & Mobile Variable Displacement Piston Pumps V-PUPI-TM007-E February 2009
This page intentionally blank.
© 2009 Eaton Corporation
All Rights Reserved
Printed in USA
Document No. V-PUPI-TM007-E
Supercedes V-PP-MC-0003-E, V-PP-MC-0004-E
February 2009
Eaton
Hydraulics Business USA
14615 Lone Oak Road
Eden Prairie, MN 55344
USA
Tel: 952-937-9800
Fax: 952-294-7722
www.eaton.com/hydraulics
Eaton
Hydraulics Business Europe
Route de la Longeraie 7
1110 Morges
Switzerland
Tel: +41 (0) 21 811 4600
Fax: +41 (0) 21 811 4601
Eaton
Hydraulics Business Asia Pacific
11th Floor Hong Kong New World Tower
300 Huaihai Zhong Road
Shanghai 200021
China
Tel: 86-21-6387-9988
Fax: 86-21-6335-3912